Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation

被引:139
作者
Beekman, FJ
de Jong, HWAM
van Geloven, S
机构
[1] Univ Utrecht, Med Ctr, Dept Nucl Med, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Ctr Med, Image Sci Inst, Dept Nucl Med, NL-3584 CX Utrecht, Netherlands
关键词
dual matrix reconstruction; image reconstruction; single photon emission computed tomography; monte carlo methods; scattering;
D O I
10.1109/TMI.2002.803130
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Quantitative accuracy of single photon emission computed tomography (SPECT) images is highly dependent on the photon scatter model used for image reconstruction. Monte Carlo simulation (MCS) is the most general method for detailed modeling of scatter, but to date, fully three-dimensional (3-D) MCS-based statistical SPECT reconstruction approaches have not been realized, due to prohibitively long computation times and excessive computer memory requirements. MCS-based reconstruction has previously been restricted to two-dimensional approaches that are vastly inferior to fully 3-D reconstruction. Instead of MCS, scatter calculations based on simplified but less accurate models are sometimes incorporated in fully 3-D SPECT reconstruction algorithms. We developed a computationally efficient fully 3-D MCS-based reconstruction architecture by combining the following methods: 1) a dual matrix ordered subset (DM-OS) reconstruction algorithm to accelerate the reconstruction and avoid massive transition matrix precalculation and storage; 2) a stochastic photon transport calculation in MCS is combined with an analytic detector modeling step to reduce noise in the Monte Carlo (MC)-based reprojection after only a small number of photon histories have been tracked; and 3) the number of photon histories simulated is reduced by an order of magnitude in early iterations, or photon histories calculated in an early iteration are reused. For a 64 x 64 x 64 image array, the reconstruction time required for ten DM-OS iterations is approximately 30 min on a dual processor (AMD 1.4 GHz) PC, in which case the stochastic nature of MCS modeling is found to have a negligible effect on noise in reconstructions. Since MCS can calculate photon transport for any clinically used photon energy and patient attenuation distribution, the proposed methodology is expected to be useful for obtaining highly accurate quantitative SPECT images within clinically acceptable computation times.
引用
收藏
页码:867 / 877
页数:11
相关论文
共 52 条
[21]  
Hutton BF, 1997, EUR J NUCL MED, V24, P797
[22]   Efficient scatter modelling for incorporation in maximum likelihood reconstruction [J].
Hutton, BF ;
Baccarne, V .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (12) :1658-1665
[23]  
Iida H, 1998, J NUCL MED, V39, P181
[24]   Design and experimental validation of a quantitative myocardial 201Tl SPECT system [J].
Iida, H ;
Shoji, Y ;
Sugawara, S ;
Kinoshita, T ;
Tamura, Y ;
Narita, Y ;
Eberl, S .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :720-726
[25]   Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction [J].
Kadrmas, DJ ;
Frey, EC ;
Karimi, SS ;
Tsui, BMW .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :857-873
[26]   Application of reconstruction-based scatter compensation to thallium-201 SPECT: Implementations for reduced reconstructed image noise [J].
Kadrmas, DJ ;
Frey, EC ;
Tsui, BMW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) :325-333
[27]  
Kadrmas DJ, 1996, 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, P1097
[28]  
Kamphuis C, 1998, EUR J NUCL MED, V25, P8
[29]   Evaluation of OS-EM vs ML-EM for 1D, 2D and fully 3D SPECT reconstruction [J].
Kamphuis, C ;
Beekman, FJ ;
Viergever, MA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :2018-2024
[30]   A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agents [J].
King, MA ;
Xia, WS ;
deVries, DJ ;
Pan, TS ;
Villegas, BJ ;
Dahlberg, S ;
Tsui, BMW ;
Ljungberg, MH ;
Morgan, HT .
JOURNAL OF NUCLEAR CARDIOLOGY, 1996, 3 (01) :18-29