Analysis of low Z elements in various environmental samples with total reflection X-ray fluorescence (TXRF) spectrometry

被引:41
作者
Hoefler, H.
Streli, C. [1 ]
Wobrauschek, P.
Ovari, M.
Zaray, Gy.
机构
[1] TU Wien, Atominst Austrian Univ, A-1020 Vienna, Austria
[2] Eotvos Lorand Univ, Inst Chem, H-1117 Budapest, Hungary
关键词
TXRF; low Z elements; self absorption; biofilms;
D O I
10.1016/j.sab.2006.07.005
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Recently there is a growing interest in low Z elements such as carbon, oxygen up to sulphur and phosphorus in biological specimen. Total reflection X-ray fluorescence (TXRF) spectrometry is a suitable technique demanding only very small amounts of sample. On the other side, the detection of low Z elements is a critical point of this analytical technique. Besides other effects, self absorption may occur in the samples, because of the low energy of the fluorescence radiation. The calibration curves might be not linear any longer. To investigate this issue water samples and samples from human cerebrospinal fluid were used to examine absorption effects. The linearity of calibration curves in dependence of sample mass was investigated to verify the validity of the thin film approximation. The special requirements to the experimental setup for low Z energy dispersive fluorescence analysis were met by using the Atominstitute's TXRF vacuum chamber. This spectrometer is equipped with a Cr-anode X-ray tube, a multilayer monochromator and a SiLi detector with 30 mm(2) active area and with an ultrathin entrance window. Other object on this study are biofilms, living on all subaqueous surfaces, consisting of bacteria, algae and fungi embedded in their extracellular polymeric substances (EPS). Many trace elements from the water are bound in the biofilm. Thus, the biofilm is a useful indicator for polluting elements. For biomonitoring purposes not only the polluting elements but also the formation and growth rate of the biofilm are important. Biofilms were directly grown on TXRF reflectors. Their major elements and C-masses correlated to the cultivation time were investigated. These measured masses were related to the area seen by the detector, which was experimentally determined. Homogeneity of the biofilms was checked by measuring various sample positions on the reflectors. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1135 / 1140
页数:6
相关论文
共 8 条
[1]   Biofilms as bio-indicator for polluted waters?: Total reflection X-ray fluorescence analysis of biofilms of the Tisza river (Hungary) [J].
Mages, M ;
Ovari, M ;
von Tumpling, W ;
Kröpfl, K .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (04) :1095-1101
[2]   Analysis of some chosen elements of cerebrospinal fluid and serum in amyotrophic lateral sclerosis patients by total reflection X-ray fluorescence [J].
Ostachowicz, B. ;
Lankosz, M. ;
Tomik, B. ;
Adamek, D. ;
Wobrauschek, P. ;
Streli, C. ;
Kregsamer, P. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (10-11) :1210-1213
[3]   Total reflection X-ray fluorescence spectrometric determination of element inlets from mining activities at the upper Tisza, catchment area, Hungary [J].
Ovári, M ;
Mages, M ;
Woelfl, S ;
von Tümpling, W ;
Kröpfl, K ;
Záray, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) :1173-1181
[4]   A method for trace element determination of marine periphyton communities on discs of float glass (without sample preparation) using total-reflection X-ray fluorescence spectrometry [J].
Pettersson, RP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (01) :101-115
[5]   Low Z total reflection X-ray fluorescence analysis - challenges and answers [J].
Streli, C ;
Kregsamer, P ;
Wobrauschek, P ;
Gatterbauer, H ;
Pianetta, P ;
Pahlke, S ;
Fabry, L ;
Palmetshofer, L ;
Schmeling, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (10) :1433-1441
[6]   Total reflection X-ray fluorescence analysis of light elements with synchrotron radiation and special X-ray tubes [J].
Streli, C ;
Wobrauschek, P ;
Bauer, V ;
Kregsamer, P ;
Gorgl, R ;
Pianetta, P ;
Ryon, R ;
Pahlke, S ;
Fabry, L .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (07) :861-872
[7]   Comparison of SiLi detector and silicon drift detector for the determination of low Z elements in total reflection X-ray fluorescence [J].
Streli, C ;
Wobrauschek, P ;
Schraik, I .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) :1211-1213
[8]  
Streli C., 2003, P 46 ANN HUNG SPECTR, P22