Magnetic resonance monitoring of stent deployment -: In vitro evaluation of different stent designs and stent delivery systems

被引:17
作者
Manke, C [1 ]
Nitz, WR [1 ]
Lenhart, M [1 ]
Völk, M [1 ]
Geissler, A [1 ]
Feuerbach, S [1 ]
Link, J [1 ]
机构
[1] Univ Regensburg, Dept Radiol, D-8400 Regensburg, Germany
关键词
magnetic resonance; guidance; rapid imaging; stents and prostheses;
D O I
10.1097/00004424-200006000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO evaluate MR imaging features of commercially available stents before, during, and after in vitro deployment as a step toward MR-guided stent deployment. METHODS. Fourteen stents were deployed in a phantom under MR monitoring at 1.5 T by using a gradient-echo sequence. Device visibility was rated on a four-point scale (excellent, fair, poor, not visible). RESULTS. The Memotherm stent and the rolling membrane (RM) Wallstent showed excellent stent visibility and at least fair scores for artifact-induced narrowing of the stent lumen. Three stents (Palmaz, AVE, Easy Wallstent) showed excellent visibility of the stent but no visible lumen. Five stents (Strecker, Accuflex, Hemobahn, Passager, Sinus) displayed fair visibility. The delivery catheters of four stent systems (Smart, Vascucoil, Symphony, ZA) displayed severe black hole artifacts. CONCLUSIONS. The imaging features of several stent systems might be suitable for MR-guided intervention. The Memotherm and the Wallstent RM combine good visibility of the stent and the lumen.
引用
收藏
页码:343 / 351
页数:9
相关论文
共 30 条
[1]   Visualization of MR-compatible catheters by electrically induced local field inhomogeneities:: Evaluation in vivo [J].
Adam, G ;
Glowinski, A ;
Neuerburg, J ;
Bücker, A ;
van Vaals, JJ ;
Günther, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :209-213
[2]   MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique [J].
Bakker, CJ ;
Hoogeveen, RM ;
Hurtak, WF ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WPTM .
RADIOLOGY, 1997, 202 (01) :273-276
[3]   Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions [J].
Bakker, CJ ;
Hoogeveen, RM ;
Weber, J ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WP .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :816-820
[4]   MR-guided balloon angioplasty: In vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions [J].
Bakker, CJ ;
Smits, HF ;
Bos, C ;
van der Weide, R ;
Zuiderveld, KJ ;
van Vaals, JJ ;
Hurtak, WF ;
Viergever, MA ;
Mall, WP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :245-250
[5]   SHUNTS FOR PORTAL-HYPERTENSION - MR AND ANGIOGRAPHY FOR DETERMINATION OF PATENCY [J].
BERNARDINO, ME ;
STEINBERG, HV ;
PEARSON, TC ;
GEDGAUDASMCCLEES, RK ;
TORRES, WE ;
HENDERSON, JM .
RADIOLOGY, 1986, 158 (01) :57-61
[6]   Stent placement under real-time MR control:: First experience in an animal model. [J].
Bücker, A ;
Neuerburg, JM ;
Adam, G ;
Schürmann, K ;
Rasche, V ;
van Vaals, JJ ;
Molgaard-Nielsen, A ;
Günther, RW .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (06) :655-657
[7]   HEAD AND NECK LESIONS - MR-GUIDED ASPIRATION BIOPSY [J].
DUCKWILER, G ;
LUFKIN, RB ;
TERESI, L ;
SPICKLER, E ;
DION, J ;
VINUELA, F ;
BENTSON, J ;
HANAFEE, W .
RADIOLOGY, 1989, 170 (02) :519-522
[8]   CORONARY MR-ANGIOGRAPHY AFTER CORONARY STENT PLACEMENT [J].
DUERINCKX, AJ ;
ATKINSON, D ;
HURWITZ, R ;
MINTOROVITCH, J ;
WHITNEY, W .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) :662-664
[9]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415
[10]   EFFECT OF FIELD-STRENGTH ON SUSCEPTIBILITY ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING [J].
FARAHANI, K ;
SINHA, U ;
SINHA, S ;
CHIU, LCL ;
LUFKIN, RB .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1990, 14 (06) :409-413