Quantification and thickness correction of EFTEM phosphorus maps

被引:20
作者
Aronova, M. A.
Kim, Y. C.
Zhang, G.
Leapman, R. D. [1 ]
机构
[1] NIH, Div Bioengn & Phys Sci, ORS, Bethesda, MD 20892 USA
[2] NIDDK, Chem Phys Lab, NIH, Bethesda, MD 20892 USA
关键词
energy filtered transmission electron microscopy (EFTEM); electron energy loss spectroscopy (EELS); plural scattering; elemental mapping; phosphorus;
D O I
10.1016/j.ultramic.2006.07.009
中图分类号
TH742 [显微镜];
学科分类号
摘要
We describe a method for correcting plural inelastic scattering effects in elemental maps that are acquired in the energy filtering transmission electron microscope (EFTEM) using just two energy windows, one above and one below a core edge in the electron energy loss spectrum (EELS). The technique is demonstrated for mapping low concentrations of phosphorus in biological samples. First, the single-scattering EELS distributions are obtained from specimens of pure carbon and plastic embedding material. Then, spectra are calculated for different specimen thicknesses t, expressed in units of the inelastic mean free path lambda. In this way, standard curves are generated for the ratio k(0) of post-edge to pre-edge intensities at the phosphorus L-2,L-3 excitation energy, as a function of relative specimen thickness t/lambda. Thickness effects in a two-window phosphorus map are corrected by successive acquisition of zero-loss and unfiltered images, from which it is possible to determine a t/lambda, image and hence a background k(0)-ratio image. Knowledge of the thickness-dependent k(0)-ratio at each pixel thus enables a more accurate determination of the phosphorus distribution in the specimen. Systematic and statistical errors are calculated as a function of specimen thickness, and elemental maps are quantified in terms of the number of phosphorus atoms per pixel. Further analysis of the k(0)-curve shows that the EFTEM can be used to obtain reliable two-window phosphorus maps from specimens that are considerably thicker than previously possible. Published by Elsevier B.V.
引用
收藏
页码:232 / 244
页数:13
相关论文
共 39 条
[1]
EXPERIMENTAL ENERGY-LOSS FUNCTION, IM[-1/EPSILON(Q,OMEGA)], FOR ALUMINUM [J].
BATSON, PE ;
SILCOX, J .
PHYSICAL REVIEW B, 1983, 27 (09) :5224-5239
[2]
Stoichiometric analysis of protein- and nucleic acid-based structures in the cell nucleus [J].
Bazett-Jones, DP ;
Hendzel, MJ ;
Kruhlak, MJ .
MICRON, 1999, 30 (02) :151-157
[3]
SHORT-RANGE DNA LOOPING BY THE XENOPUS HMG-BOX TRANSCRIPTION FACTOR, XUBF [J].
BAZETTJONES, DP ;
LEBLANC, B ;
HERFORT, M ;
MOSS, T .
SCIENCE, 1994, 264 (5162) :1134-1137
[4]
A sub-50 meV spectrometer and energy filter for use in combination with 200 kV monochromated (S)TEMs [J].
Brink, HA ;
Barfels, MMG ;
Burgner, RP ;
Edwards, BN .
ULTRAMICROSCOPY, 2003, 96 (3-4) :367-384
[5]
Egerton R. F., 1996, ELECT ENERGY LOSS SP
[6]
Egerton R. F., 1981, P 39 ANN P EL MICR S, P198
[7]
FORMULAS FOR LIGHT-ELEMENT MICROANALYSIS BY ELECTRON ENERGY-LOSS SPECTROMETRY [J].
EGERTON, RF .
ULTRAMICROSCOPY, 1978, 3 (02) :243-251
[8]
[9]
K-SHELL IONIZATION CROSS-SECTIONS FOR USE IN MICROANALYSIS [J].
EGERTON, RF .
ULTRAMICROSCOPY, 1979, 4 (02) :169-179
[10]
A REVISED EXPRESSION FOR SIGNAL NOISE RATIO IN EELS [J].
EGERTON, RF .
ULTRAMICROSCOPY, 1982, 9 (04) :387-390