Influence of total hip design on dislocation - A computer model and clinical analysis

被引:44
作者
Padgett, Douglas E. [1 ]
Lipman, Joseph [1 ]
Robie, Bruce [1 ]
Nestor, Bryan J. [1 ]
机构
[1] Hosp Special Surg, Weill Cornell Med Coll, New York, NY 10021 USA
关键词
D O I
10.1097/01.blo.0000218748.30236.40
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Dislocation following hip arthroplasty remains problematic. While the etiology of dislocation may be multifactorial, implant system design may play a role. Using a computer aided design program, virtual range of motion of several commonly implanted designs was performed with prosthetic interference representing impingement used as an endpoint. Implants with small diameter head size (22mm) and a larger trunion geometry (type II taper) demonstrated impingement in flexion at less than 90 degrees, suggesting an increased risk for dislocation. To investigate this clinically, we performed a review of a consecutive series of 254 primary hip arthroplasties performed by a single surgeon using an implant with a type II taper (Biomet(TM), Warsaw, IN). At a minimum 2 year followup, 12 patients with 12 hips (4.8%) had at least one episode of dislocation. Stratified by head size, the dislocation rates were 3.6% for 28 mm, 4.8% for 26 mm, and 18.8% for 22mm bearings. These findings support the notion that computer aided design modeling of implant systems is useful in evaluating range of motion and this technique could be employed during the design of any new implant system.
引用
收藏
页码:48 / 52
页数:5
相关论文
共 12 条
[1]
The influence of head and neck geometry on stability of total hip replacement - A mechanical test study [J].
Bader, R ;
Scholz, R ;
Steinhauser, E ;
Zimmermann, S ;
Busch, R ;
Mittelmeier, W .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (04) :415-421
[2]
Stem design and dislocation after revision total hip arthroplasty - Clinical results and computer modeling [J].
Barrack, RL ;
Butler, RA ;
Laster, DR ;
Andrews, P .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :8-12
[3]
Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty [J].
Barrack, RL ;
Lavernia, C ;
Ries, M ;
Thornberry, R ;
Tozakoglou, E .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (04) :569-+
[4]
The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[5]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[6]
Factors predisposing to dislocation after primary total hip arthroplasty - A multivariate analysis [J].
Jolles, BM ;
Zangger, P ;
Leyvraz, PF .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :282-288
[7]
DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[8]
The unstable total hip replacement [J].
Padgett, DE ;
Warashina, H .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) :72-79
[9]
A finite element analysis of factors influencing total hip dislocation [J].
Scifert, CF ;
Brown, TD ;
Pedersen, DR ;
Callaghan, JJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (355) :152-162
[10]
Impingement in total hip arthroplasty - A study of retrieved acetabular components [J].
Shon, WY ;
Baldini, T ;
Peterson, MG ;
Wright, TM ;
Salvati, EA .
JOURNAL OF ARTHROPLASTY, 2005, 20 (04) :427-435