Graphene/AuNPs/chitosan nanocomposites film for glucose biosensing

被引:674
作者
Shan, Changsheng [1 ]
Yang, Huafeng [1 ]
Han, Dongxue [1 ,2 ]
Zhang, Qixian [1 ]
Ivaska, Ari [2 ]
Niu, Li [1 ,2 ]
机构
[1] Chinese Acad Sci, Grad Univ, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Peoples R China
[2] Abo Akad Univ, Proc Chem Ctr, Analyt Chem Lab, FI-20500 Turku, Finland
关键词
Graphene nanocomposites; Gold nanoparticles; Glucose oxidase; Biosensors; Electroanalysis; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL BIOSENSORS; GRAPHENE SHEETS; COMPOSITE FILM; IONIC LIQUID; NANOTUBES; OXIDASE; NANOPARTICLES; CHITOSAN; MATRIX;
D O I
10.1016/j.bios.2009.09.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel glucose biosensor based on immobilization of glucose oxidase in thin films of chitosan containing nanocomposites of graphene and gold nanoparticles (AuNPs) at a gold electrode was developed. The resulting graphene/AuNPs/chitosan composites film exhibited good electrocatalytical activity toward H2O2 and O-2. The wide linear response to H2O2 ranging from 0.2 to 4.2 mM (R = 0.998) at -0.2 V, high sensitivity of 99.5 mu A mM(-1) cm(-2) and good reproducibility were obtained. The good electrocatalytical activity might be attributed to the synergistic effect of graphene and AuNPs. With glucose oxidase (GOD) as a model, the graphene/AuNPs/GOD/chitosan composite-modi fled electrode was constructed through a simple casting method. The resulting biosensor exhibited good amperometric response to glucose with linear range from 2 to 10 mM (R = 0.999) at -0.2 V and from 2 to 14 mM (R = 0.999) at 0.5 V, good reproducibility and detection limit of 180 mu M. Glucose concentration in human blood was studied preliminarily. From 2.5 to 7.5 mM, the cathodic peak currents of the biosensor decrease linearly with increasing the glucose concentrations. The graphene/AuNPs/GOD/chitosan composites film shows prominent electrochemical response to glucose, which makes a promising application for electrochemical detection of glucose. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1070 / 1074
页数:5
相关论文
共 51 条
[1]   Electrochemical biosensors for medical and food applications [J].
Ahmed, Minhaz Uddin ;
Hossain, Mohammad Mosharraf ;
Tamiya, Eiichi .
ELECTROANALYSIS, 2008, 20 (06) :616-626
[2]   Bioelectrochemical single-walled carbon nanotubes [J].
Azamian, BR ;
Davis, JJ ;
Coleman, KS ;
Bagshaw, CB ;
Green, MLH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (43) :12664-12665
[3]   Electromechanical resonators from graphene sheets [J].
Bunch, J. Scott ;
van der Zande, Arend M. ;
Verbridge, Scott S. ;
Frank, Ian W. ;
Tanenbaum, David M. ;
Parpia, Jeevak M. ;
Craighead, Harold G. ;
McEuen, Paul L. .
SCIENCE, 2007, 315 (5811) :490-493
[4]  
Cassagneau T, 1998, ADV MATER, V10, P877, DOI 10.1002/(SICI)1521-4095(199808)10:11<877::AID-ADMA877>3.0.CO
[5]  
2-1
[6]   Mechanically strong, electrically conductive, and biocompatible graphene paper [J].
Chen, Haiqun ;
Mueller, Marc B. ;
Gilmore, Kerry J. ;
Wallace, Gordon G. ;
Li, Dan .
ADVANCED MATERIALS, 2008, 20 (18) :3557-+
[7]   Technical and clinical evaluation of an electrochemistry glucose meter: experience in a diabetes center [J].
Chen, HS ;
Kuo, BI ;
Hwu, CM ;
Shih, KC ;
Kwok, CF ;
Ho, LT .
DIABETES RESEARCH AND CLINICAL PRACTICE, 1998, 42 (01) :9-15
[8]   Amperometric glucose biosensor based on glucose oxidase encapsulated in carbon nanotube-titania-nafion composite film on platinized glassy carbon electrode [J].
Choi, Han Nim ;
Han, Jee Hoon ;
Park, Ji Ae ;
Lee, Joong Min ;
Lee, Won-Yong .
ELECTROANALYSIS, 2007, 19 (17) :1757-1763
[9]   Accuracy of the EasyTouch blood glucose self-monitoring system: a study of 516 cases [J].
Dai, KS ;
Tai, DY ;
Ho, P ;
Chen, CC ;
Peng, WC ;
Chen, ST ;
Hsu, CC ;
Liu, YP ;
Hsieh, HC ;
Yang, CC ;
Tsai, MC ;
Mao, SJT .
CLINICA CHIMICA ACTA, 2004, 349 (1-2) :135-141
[10]   Electrochemical DNA sensors [J].
Drummond, TG ;
Hill, MG ;
Barton, JK .
NATURE BIOTECHNOLOGY, 2003, 21 (10) :1192-1199