Magnetoencephalography may help to improve functional MRI brain mapping

被引:32
作者
Beisteiner, R
Erdler, M
Teichtmeister, C
Diemling, M
Moser, E
Edward, V
Deecke, L
机构
[1] UNIV VIENNA, INST MED PHYS, NMR GRP, A-1090 VIENNA, AUSTRIA
[2] UNIV VIENNA, MAGNET RESONANCE UNIT, A-1090 VIENNA, AUSTRIA
关键词
human motor cortex; neuronal localization; MEG; large vessel effects; FMRI;
D O I
10.1111/j.1460-9568.1997.tb01457.x
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The validity of functional magnetic resonance imaging (FMRI) brain maps with respect to the sites of neuronal activation is still unknown. One source of localization error may be pixels with large signal amplitudes, since such pixels may be expected to overlie large vessels, running remote from the centre of neuronal activation. In this study, magnetoencephalography was used to determine the centre of neuronal activation in a simple finger tapping task. The localization accuracy of conventional FMRI depending on FMRI signal enhancement was investigated relative to the magnetoencephalography reference. The results show a deterioration of FMRI localization with increasing signal amplitude related to increased contributions from large vessels. We conclude that FMRI data analysis should exclude large signal amplitudes and that magnetoencephalography may help to improve FMRI brain mapping results in a multimethod approach.
引用
收藏
页码:1072 / 1077
页数:6
相关论文
共 33 条
  • [1] LOCALIZATION OF IMPLANTED DIPOLES BY MAGNETOENCEPHALOGRAPHY
    BALISH, M
    SATO, S
    CONNAUGHTON, P
    KUFTA, C
    [J]. NEUROLOGY, 1991, 41 (07) : 1072 - 1076
  • [2] PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN
    BANDETTINI, PA
    JESMANOWICZ, A
    WONG, EC
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 161 - 173
  • [3] COMPARING LOCALIZATION OF CONVENTIONAL FUNCTIONAL MAGNETIC-RESONANCE-IMAGING AND MAGNETOENCEPHALOGRAPHY
    BEISTEINER, R
    GOMISCEK, G
    ERDLER, M
    TEICHTMEISTER, C
    MOSER, E
    DEECKE, L
    [J]. EUROPEAN JOURNAL OF NEUROSCIENCE, 1995, 7 (05) : 1121 - 1124
  • [4] EVALUATING CONVENTIONAL FMRI WITH RESPECT TO NONINVASIVE LOCALIZATION OF NEURONAL-ACTIVITY
    BEISTEINER, R
    ERDLER, M
    TEICHTMEISTER, C
    MOSER, E
    DEECKE, L
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (2-3) : 225 - &
  • [5] BEISTEINER R, 1997, IN PRESS FUNCTIONAL
  • [6] BELLIVEAU JW, 1993, P SMRM 12 ANN M NEW, V1, P6
  • [7] BUCHER SF, 1995, RADIOLOGE, V35, P228
  • [8] Callaghan PT., 1993, Principles of Nuclear Magnetic Resonance Microscopy
  • [9] MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN
    COHEN, D
    CUFFIN, BN
    YUNOKUCHI, K
    MANIEWSKI, R
    PURCELL, C
    COSGROVE, GR
    IVES, J
    KENNEDY, JG
    SCHOMER, DL
    [J]. ANNALS OF NEUROLOGY, 1990, 28 (06) : 811 - 817
  • [10] DIEMLING M, 1997, IN PRESS MAGN RES IM