Fiber optic SPR biosensing of DNA hybridization and DNA-protein interactions

被引:200
作者
Pollet, Jeroen [1 ]
Delport, Filip [1 ]
Janssen, Kris P. F. [1 ]
Jans, Karolien [2 ]
Maes, Guido [3 ]
Pfeiffer, Helge [4 ]
Wevers, Martine [4 ]
Lammertyn, Jeroen [1 ]
机构
[1] Katholieke Univ Leuven, BIOSYST MeBioS, B-3001 Louvain, Belgium
[2] IMEC, B-3001 Louvain, Belgium
[3] Katholieke Univ Leuven, Quantum Chem & Phys Chem Sect, B-3001 Louvain, Belgium
[4] Katholieke Univ Leuven, Mech Met Sect, B-3001 Louvain, Belgium
关键词
DNA hybridization; Aptamers; Surface plasmon resonance; Fiber optic biosensor; DNA-protein interactions; SURFACE-PLASMON RESONANCE; PROBE CAPILLARY-ELECTROPHORESIS; WHITE-LIGHT; HUMAN IGE; APTAMERS; SENSOR; IMMUNOGLOBULIN; MOLECULES; LIGANDS; BINDING;
D O I
10.1016/j.bios.2009.08.045
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper we present a fiber optic surface plasmon resonance (SPR) sensor as a reusable, cost-effective and label free biosensor for measuring DNA hybridization and DNA-protein interactions. This is the first paper that combines the concept of a fiber-based SPR system with DNA aptamer bioreceptors. The fibers were sputtered with a 50 nm gold layer which was then covered with a protein repulsive self-assembled monolayer of mixed polyethylene glycol (PEG). Streptavidin was attached to the PEG's carboxyl groups to serve as a versatile binding element for biotinylated ssDNA. The ssDNA coated SPR fibers were first evaluated as a nucleic acid biosensor through a DNA-DNA hybridization assay for a random 37-mer ssDNA. This single stranded DNA showed a 15 nucleotides overlap with the receptor ssDNA on the SPR fiber. A linear calibration curve was observed in 0.5-5 mu M range. A negative control test did not reveal any significant non-specific binding, and the biosensor was easily regenerated. In a second assay the fiber optic SPR biosensor was functionalized with ssDNA aptamers against human immunoglobulin E. Limits of detection (2 nM) and quantification (6 nM) in the low nanomolar range were observed. The presented biosensor was not only useful for DNA and protein quantification purposes, but also to reveal the binding kinetics occurring at the sensor surface. The dissociation constant between aptamer and hIgE was equal to 30.9 +/- 2.9 nM. The observed kinetics fully comply with most data from the literature and were also confirmed by own control measurements. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:864 / 869
页数:6
相关论文
共 26 条
[1]   Non-SELEX: selection of aptamers without intermediate amplification of candidate oligonucleotides [J].
Berezovski, Maxim V. ;
Musheev, Michael U. ;
Drabovich, Andrei P. ;
Jitkova, Julia V. ;
Krylov, Sergey N. .
NATURE PROTOCOLS, 2006, 1 (03) :1359-1369
[2]   Effect of buffer, electric field, and separation time on detection of aptamer-ligand complexes for affinity probe capillary electrophoresis [J].
Buchanan, DD ;
Jameson, EE ;
Perlette, J ;
Malik, A ;
Kennedy, RT .
ELECTROPHORESIS, 2003, 24 (09) :1375-1382
[3]   Aptamers as recognition elements for label-free analytical devices [J].
de-los-Santos-Alvarez, Noemi ;
Jesus Lobo-Castanon, Maria ;
Miranda-Ordieres, Arturo J. ;
Tunon-Blanco, Paulino .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (05) :437-446
[4]   Capturing Single Molecules of Immunoglobulin and Ricin with an Aptamer-Encoded Glass Nanopore [J].
Ding, Shu ;
Gao, Changlu ;
Gu, Li-Qun .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :6649-6655
[5]   Aptamers as ligands in affinity probe capillary electrophoresis [J].
German, I ;
Buchanan, DD ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 1998, 70 (21) :4540-4545
[6]   Frontal analysis in microchip CE: A simple and accurate method for determination of protein-DNA dissociation constant [J].
Gong, Maojun ;
Wehmeyer, Kenneth R. ;
Limbach, Patrick A. ;
Heineman, William R. .
ELECTROPHORESIS, 2007, 28 (05) :837-842
[7]   Fibre optic refractive index microsensor based on white-light SPR excitation [J].
Grunwald, B ;
Holst, G .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 113 (02) :174-180
[8]  
Homola J, 2006, SPRINGER SER CHEM SE, V4, P45, DOI 10.1007/5346_014
[9]   Stability of mixed PEO-thiol SAMs for biosensing applications [J].
Jans, Karolien ;
Bonroy, Kristien ;
De Palma, Randy ;
Reekmans, Gunter ;
Jans, Hilde ;
Laureyn, Wim ;
Smet, Mario ;
Borghs, Gustaaf ;
Maes, Guido .
LANGMUIR, 2008, 24 (08) :3949-3954
[10]  
Jayasena SD, 1999, CLIN CHEM, V45, P1628