Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: Are unenhanced and delayed phase enhanced images effective for endoleak detection?

被引:78
作者
Iezzi, Roberto
Cotroneo, Antonio Raffaele
Filippone, Antonella
Di Fabio, Francesca
Quinto, Fabio
Colosimo, Cesare
Bonomo, Lorenzo
机构
[1] Univ G DAnnunzio, SS Annunziata Hosp, Sect Radiol, Dept Clin Sci & Bioimaging, I-66013 Chieti, Italy
[2] Catholic Univ, Inst Radiol, Dept Bioimaging & Radiol Sci, Rome, Italy
关键词
D O I
10.1148/radiol.2413050959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively determine the sensitivity and specificity of enhanced, delayed enchanced phase (DEP), and arterial enhanced phase (AEP) multi-detector row computed tomography (CT) for depicting endoleaks during follow-up of endovascular aneurysm repair. Materials and Methods: Fifty patients (two women, 48 men; mean age, 72 years) underwent follow-up multi-detector row CT 1, 6, and 12 months after endovascular aneurysm repair. Unenhanced CT was performed with 2.5-mm collimation; 1-mm was used with AEP and DEP examinations. Two independent readers assessed the presence of endoleak in three reading Sessions: AEP (session A), unenhanced and AEP (session B), and AEP and DEP (session C). At 6- and 12-month follow-up, a fourth set was included: 1-month unenhanced and AEP (session D). Sensitivity, specificity, and positive predictive value of each session were calculated. Triple-phase multi-detector row CT was the reference standard. Results: At 1 month, sensitivity, specificity, and positive predictive value, respectively, were 79%, 75%, and 55% for session A; 93%, 97%, and 93% for session B; and 93%, 78%, and 62% for session C. At 6 months, sensitivity, specificity, and positive predictive value, respectively, were 92%, 68%, and 48% for session A; 92%, 100%, and 100% for session B; and 100%, 84%, and 67% for session C. At 12 months sensitivity specificity, and positive predictive value, respectively,, were 80%, 80%, and 50% for session A; 90%, 98%, and '90% for session B; and 100% and 56% for session C. 80%,, Sensitivity did not significantly differ (P >.05) among reading sessions A, B, and C, whereas specificity and positive predictive, values in session B were significantly higher (P <.001). For 6 and 12-month follow-up, no significant differences (P >.05) were found between sessions D and B. Conclusion: The combination of AEP and unenhanced imaging performed at 1-month follow-up offers improved specificity and positive predictive values compared with AEP alone.. DEP imaging does not, significantly increase sensitivity for detection of endoleaks, but it does depict low-flow endoleaks not seen at AEP.
引用
收藏
页码:915 / 921
页数:7
相关论文
共 25 条
[21]   Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: Value of unenhanced and delayed helical CT acquisitions [J].
Rozenblit, AM ;
Patlas, M ;
Rosenbaum, AT ;
Okhi, T ;
Veith, FJ ;
Laks, MP ;
Ricci, ZJ .
RADIOLOGY, 2003, 227 (02) :426-433
[22]   Analysis of initial CT findings after endovascular repair of abdominal aortic aneurysm [J].
Sawhney, R ;
Kerlan, RK ;
Wall, SD ;
Chuter, TAM ;
Ruiz, DE ;
Canto, CJ ;
LaBerge, JM ;
Reilly, LM ;
Yee, J ;
Wilson, MW ;
Jean-Claude, J ;
Faruqi, RM ;
Gordon, RL .
RADIOLOGY, 2001, 220 (01) :157-160
[23]   Type II endoleaks after endovascular repair of abdominal aortic aneurysms: Natural history [J].
Tolia, AJ ;
Landis, R ;
Lamparello, P ;
Rosen, R ;
Macari, M .
RADIOLOGY, 2005, 235 (02) :683-686
[24]   Lessons learnt from the EUROSTAR registry on endovascular repair of abdominal aortic aneurysm repair [J].
Vallabhaneni, SR ;
Harris, PL .
EUROPEAN JOURNAL OF RADIOLOGY, 2001, 39 (01) :34-41
[25]   Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial [J].
Zarins, CK ;
White, RA ;
Hodgson, KJ ;
Schwarten, D ;
Fogarty, TJ .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (01) :90-107