Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector

被引:58
作者
Dobbins, JT
Samei, E
Chotas, HG
Warp, RJ
Baydush, AH
Floyd, CE
Ravin, CE
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27710 USA
关键词
flat panel detector; radiography; digital;
D O I
10.1148/radiol.2261012023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To ascertain the optimum x-ray spectrum for chest radiography with a cesium iodide-amorphous silicon flat-panel detector. MATERIALS AND METHODS: End points for optimization included the ratio of tissue contrast to bone contrast and a figure of merit (FOM) equal to the square of the signal-to-noise ratio of tissue divided by incident exposure to the patient. Studies were conducted with both computer spectrum modeling and experimental measurement in narrow-beam and full-field exposure conditions for four tissue thicknesses (8-32 cm). Three parameters that affect spectra were considered: the atomic number (Z) of filter material (Z = 13, 26, 29, 42, 50, 56, 64, 74, and 82), kilovoltage (from 50 to 150 kVp), and filter thickness (from 0.25 to 2.00 half-value layer [HVL]). RESULTS: Computer modeling and narrow-beam experimental data showed similar trends for the full range of parameters evaluated. Spectrum model results showed that copper filtration at 120 kVp or more was optimum for FOM. The ratio of contrasts showed a trend to be higher with higher kilovoltage and only a minor variation with filter material. Full-field experimental results, which reflect the added contribution of x-ray scatter, differed in magnitude but not trends from the narrow-beam data in all cases except the ratio of contrasts in the mediastinum. CONCLUSION: The best performance overall, including both FOM and ratio of contrasts, was at 120 kVp with 1-HVL copper filtration (0.2 mm). With this beam spectrum and an increase in tube output (ie, milliampere seconds) of about 50%, a chest radiograph can be obtained with image quality approximately equal to that with a conventional spectrum but with about 25% less patient exposure. (C) RSNA, 2002.
引用
收藏
页码:221 / 230
页数:10
相关论文
共 18 条
[1]  
[Anonymous], 60113 IEC
[2]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[3]   PHYSICAL MEASUREMENTS OF HEAVY-METAL FILTER PERFORMANCE [J].
BURGESS, AE .
MEDICAL PHYSICS, 1985, 12 (02) :225-228
[4]   DIGITAL CHEST RADIOGRAPHY WITH PHOTOSTIMULABLE STORAGE PHOSPHORS - SIGNAL-TO-NOISE RATIO AS A FUNCTION OF KILOVOLTAGE WITH MATCHED EXPOSURE RISK [J].
CHOTAS, HG ;
FLOYD, CE ;
DOBBINS, JT ;
RAVIN, CE .
RADIOLOGY, 1993, 186 (02) :395-398
[5]   SMALL OBJECT CONTRAST IN AMBER AND CONVENTIONAL CHEST RADIOGRAPHY [J].
CHOTAS, HG ;
VANMETTER, RL ;
JOHNSON, GA ;
RAVIN, CE .
RADIOLOGY, 1991, 180 (03) :853-859
[6]   DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES [J].
DOBBINS, JT ;
ERGUN, DL ;
RUTZ, L ;
HINSHAW, DA ;
BLUME, H ;
CLARK, DC .
MEDICAL PHYSICS, 1995, 22 (10) :1581-1593
[7]   SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY - IMPROVED DETECTION AND PROCESSING [J].
ERGUN, DL ;
MISTRETTA, CA ;
BROWN, DE ;
BYSTRIANYK, RT ;
SZE, WK ;
KELCZ, F ;
NAIDICH, DP .
RADIOLOGY, 1990, 174 (01) :243-249
[8]  
ERGUN DL, 1977, DXSPEC COMPUTER PROG
[9]   Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography [J].
Floyd, CE ;
Warp, RJ ;
Dobbins, JT ;
Chotas, HG ;
Baydush, AH ;
Vargas-Voracek, R ;
Ravin, CE .
RADIOLOGY, 2001, 218 (03) :683-688
[10]   Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications [J].
Granfors, PR ;
Aufrichtig, R .
MEDICAL PHYSICS, 2000, 27 (06) :1324-1331