Separation of acidic compounds by strong anion-exchange capillary electrochromatography

被引:67
作者
Ye, ML [1 ]
Zou, HF [1 ]
Liu, Z [1 ]
Ni, JY [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Lab Chromatog, Dalian 116011, Peoples R China
基金
中国国家自然科学基金;
关键词
electrochromatography; ion-exchange electrochromatography; mobile phase composition; benzoic acids;
D O I
10.1016/S0021-9673(00)00397-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separation of the acidic compounds in the ion-exchange capillary electrochromatograph (IE-CEC) with strong anion-exchange packing as the stationary phase was studied. It was observed that the electroosmotic flow (EOF) in strong anion-exchange CEC moderately changed with increase of the eluent ionic strength and decrease of the eluent pH, but the acetonitrile concentration in the eluent had almost no effect on the EOF. The EOF in Strong anion-exchange CEC with eluent of low pH value was much larger than that in RP-CEC with Spherisorb-ODS as the stationary phase. The retention of acidic compounds on the strong anion-exchange packing was relatively weak due to only partial ionization of them, and both chromatographic and electrophoretic processes contributed to separation. It was observed that the retention values of acidic compounds decreased with the increase of phosphate buffer and acetonitrile concentration in the eluent as well as the decrease of the applied voltage, and even the acidic compounds could elute before the void time. These factors also made an important contribution to the separation selectivity for tested acidic compounds, which could be separated rapidly with high column efficiency of more than 220 000 plates/m under the optimized separation conditions. (C) 2000 Elsevier Science BN. All rights reserved.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 32 条
[1]   Analysis of acidic compounds using capillary electrochromatography [J].
Altria, KD ;
Smith, NW ;
Turnbull, CH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 717 (1-2) :341-353
[2]  
BOSCH SE, 1996, J CHROMATOGR A, V755, P165
[3]   Dynamics of capillary electrochromatography - Experimental study on the electrosmotic flow and conductance in open and packed capillaries [J].
Choudhary, G ;
Horvath, C .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :161-183
[4]   Behavior of cation-exchange materials in capillary electrochromatography [J].
Cikalo, MG ;
Bartle, KD ;
Myers, P .
ANALYTICAL CHEMISTRY, 1999, 71 (09) :1820-1825
[5]   Capillary electrochromatography [J].
Colon, LA ;
Guo, Y ;
Fermier, A .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :A461-A467
[6]   PREPARATION, PROPERTIES AND SOME APPLICATIONS OF BONDED ION-EXCHANGE PACKINGS BASED ON MICROPARTICULATE SILICA-GEL FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COX, GB ;
LOSCOMBE, CR ;
SLUCUTT, MJ ;
SUGDEN, K ;
UPFIELD, JA .
JOURNAL OF CHROMATOGRAPHY, 1976, 117 (02) :269-278
[7]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[8]   Selectivity tuning in pressurized-flow electrochromatography [J].
Eimer, T ;
Unger, KK ;
vanderGreef, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (09) :463-468
[9]   Step-gradient capillary electrochromatography [J].
Euerby, MR ;
Gilligan, D ;
Johnson, CM ;
Bartle, KD .
ANALYST, 1997, 122 (10) :1087-1088
[10]   Capillary electrochromatography with gradient elution [J].
Huber, CG ;
Choudhary, G ;
Horvath, C .
ANALYTICAL CHEMISTRY, 1997, 69 (21) :4429-4436