Observer performance methodologies for evaluating blood vessel visibility in MR angiograms using accurate geometric registration to high resolution x-ray angiograms

被引:10
作者
Chapman, BE
Sanderson, AR
Goodrich, KC
Alexander, AL
Blatter, DD
Parker, DL
机构
[1] UNIV UTAH,SCH MED,DEPT RADIOL,MED IMAGING RES LAB,SALT LAKE CITY,UT 84132
[2] LDS HOSP,DEPT RADIOL,SALT LAKE CITY,UT
关键词
MR angiography; ROC; 2AFC; registration;
D O I
10.1002/mrm.1910370408
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Receiver operator characteristic (ROC) and two alternative forced choice (2AFC) methodologies for quantitatively assessing vessel visibility in MR angiography (MRA) were examined using x-ray angiography images as truth, The methodologies required MRA projection images with the same orientation and magnification as the x-ray images, Geometric distortions limited the quality of the registration. The observer performance measurements were compared to vessel contrast-to-noise ratio (CNR) measurements. Receiver bandwidth (RBW) and magnetization transfer (MT) effects in 3D time-off-light MRA were evaluated, Overall, applying MT significantly increased all three measurements while decreasing the RBW significantly improved the 2AFC and CNR measurements, The relative importance of both effects on the 2AFC measure increased as vessel diameter decreased, although statistical significance was limited by small samples for diameters less than approximately 0.7 mm, These results demonstrate the usefulness of these observer performance methodologies for MRA technique assessment.
引用
收藏
页码:519 / 529
页数:11
相关论文
共 26 条
[1]   RETROSPECTIVE REGISTRATION OF X-RAY ANGIOGRAMS WITH MR-IMAGES BY USING VESSELS AS INTRINSIC LANDMARKS [J].
ALPERIN, N ;
LEVIN, DN ;
PELIZZARI, CA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02) :139-144
[2]   CEREBRAL MR-ANGIOGRAPHY WITH MULTIPLE OVERLAPPING THIN SLAB ACQUISITION .1. QUANTITATIVE-ANALYSIS OF VESSEL VISIBILITY [J].
BLATTER, DD ;
PARKER, DL ;
ROBISON, RO .
RADIOLOGY, 1991, 179 (03) :805-811
[3]   COMPARISON OF RECEIVER OPERATING CHARACTERISTIC AND FORCED-CHOICE OBSERVER PERFORMANCE-MEASUREMENT METHODS [J].
BURGESS, AE .
MEDICAL PHYSICS, 1995, 22 (05) :643-655
[4]   ABBREVIATED MOMENT-COMPENSATED PHASE-ENCODING [J].
CAO, G ;
PARKER, DL ;
SHERRILL, DS ;
DU, YPP .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :179-185
[5]   VOLUME RENDERING AND CONNECTIVITY ALGORITHMS FOR MR ANGIOGRAPHY [J].
CLINE, HE ;
DUMOULIN, CL ;
LORENSEN, WE ;
SOUZA, SP ;
ADAMS, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :384-394
[6]   TABOO SEARCH - AN APPROACH TO THE MULTIPLE MINIMA PROBLEM [J].
CVIJOVIC, D ;
KLINOWSKI, J .
SCIENCE, 1995, 267 (5198) :664-666
[7]  
DAVIS W, 1994, SIGNA APPL GUIDE, V6, P35
[8]   CONTRAST-TO-NOISE-RATIO MEASUREMENTS IN 3-DIMENSIONAL MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DU, YP ;
PARKER, DL ;
DAVIS, WL ;
BLATTER, DD .
INVESTIGATIVE RADIOLOGY, 1993, 28 (11) :1004-1009
[9]   DISTORTIONS FROM CURVED FLOW IN MAGNETIC-RESONANCE-IMAGING [J].
FRANK, LR ;
BUXTON, RB .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :84-93
[10]   THE EFFICACY OF DIAGNOSTIC-IMAGING [J].
FRYBACK, DG ;
THORNBURY, JR .
MEDICAL DECISION MAKING, 1991, 11 (02) :88-94