Factors influencing the output of an implantable force transducer

被引:27
作者
Fleming, BC [1 ]
Peura, GD [1 ]
Beynnon, BD [1 ]
机构
[1] Univ Vermont, Mcclure Musculoskeletal Res Ctr, Dept Orthopaed & Rehabil, Burlington, VT 05405 USA
关键词
knee; graft; patellar tendon; transducer; force;
D O I
10.1016/S0021-9290(00)00019-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The objective of this study was to evaluate the performance of the Arthroscopically Implantable Force Probe (AIFP; MicroStrain, Burlington VT) for measuring force in a patellar tendon graft. Transducer drift, reproducibility of output due to the number of loading cycles and device location, and sensitivity to the tendon cross-sectional area were investigated. The AIFP was initialized, and then implanted into five human patellar tendon grafts three times. twice within the same location and once in a different location. The tendons were cyclically loaded in uniaxial tension for 500 cycles in each insertion site. The AIFP was then removed from the tendon and the baseline output was remeasured. It was determined that transducer drift was negligible. The relationship between the tensile load applied to the graft and AIFP output was quadratic and specimen dependent. The cyclic load response of the tendon-AIFP interface demonstrated a 24.9% decrease over the first 20 loading cycles, and subsequent cycling yielded relatively reproducible output. The output of the transducer varied when it was removed from the tendon and then reimplanted in the same location (range 3.7-109.4% error), as well as in the second location (range 1.5-202.8% error). No correlation was observed between the cross-sectional area of the tendon and transducer output. This study concludes that implantable force probes should be used with caution and calibrated without removing the transducer from the graft. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:889 / 893
页数:5
相关论文
共 17 条
[1]   INVITRO LIGAMENT TENSION PATTERN IN THE FLEXED KNEE IN PASSIVE LOADING [J].
AHMED, AM ;
HYDER, A ;
BURKE, DL ;
CHAN, KH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (02) :217-230
[2]   DIRECT INVIVO TENDON FORCE MEASUREMENT SYSTEM [J].
AN, KN ;
BERGLUND, L ;
COONEY, WP ;
CHAO, EYS ;
KOVACEVIC, N .
JOURNAL OF BIOMECHANICS, 1990, 23 (12) :1269-1271
[3]   DESIGN AND PERFORMANCE OF A MODIFIED BUCKLE TRANSDUCER FOR THE MEASUREMENT OF LIGAMENT TENSION [J].
BARRY, D ;
AHMED, AM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (02) :149-152
[4]   EFFECTS OF STRUCTURE AND STRAIN-MEASUREMENT TECHNIQUE ON THE MATERIAL PROPERTIES OF YOUNG HUMAN TENDONS AND FASCIA [J].
BUTLER, DL ;
GROOD, ES ;
NOYES, FR ;
ZERNICKE, RF ;
BRACKETT, K .
JOURNAL OF BIOMECHANICS, 1984, 17 (08) :579-596
[5]   DETERMINATION OF A ZERO STRAIN REFERENCE FOR THE ANTEROMEDIAL BAND OF THE ANTERIOR CRUCIATE LIGAMENT [J].
FLEMING, BC ;
BEYNNON, BD ;
TOHYAMA, H ;
JOHNSON, RJ ;
NICHOLS, CE ;
RENSTROM, P ;
POPE, MH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (06) :789-795
[6]   Calibration and application of an intra-articular force transducer for the measurement of patellar tendon graft forces:: an in situ evaluation [J].
Fleming, BC ;
Good, L ;
Peura, GD ;
Beynnon, BD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (04) :393-398
[7]   IN-VITRO EVALUATION OF AN IMPLANTABLE FORCE TRANSDUCER (IFT) IN A PATELLAR TENDON MODEL [J].
GLOS, DL ;
BUTLER, DL ;
GROOD, ES ;
LEVY, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :335-343
[8]   The use of an implantable force transducer to measure patellar tendon forces in goats - Response [J].
Grood, ES ;
Korvick, DL .
JOURNAL OF BIOMECHANICS, 1997, 30 (03) :305-306
[9]   Evaluation of the implantable force transducer for chronic tendon-force recordings [J].
Herzog, W ;
Archambault, JM ;
Leonard, TR ;
Nguyen, HK .
JOURNAL OF BIOMECHANICS, 1996, 29 (01) :103-109
[10]   In-situ calibration of the implantable force transducer [J].
Herzog, W ;
Hasler, EM ;
Leonard, TR .
JOURNAL OF BIOMECHANICS, 1996, 29 (12) :1649-1652