Steady-state free precession with hyperpolarized 3He:: Experiments and theory

被引:35
作者
Wild, Jim M.
Teh, Kevin
Woodhouse, Neil
Paley, Martyn N. J.
Fichele, Stan
de Zanche, Nicola
Kasuboski, Larry
机构
[1] Univ Sheffield, Royal Hallamshire Hosp, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
[2] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[3] ETH, Zurich, Switzerland
[4] Philips Med Syst, Cleveland, OH USA
基金
英国工程与自然科学研究理事会;
关键词
steady-state free precession; (3)helium; hyperpolarized; lungs; diffusion;
D O I
10.1016/j.jmr.2006.07.015
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
The magnetization response of hyperpolarized 3 He gas to a steady-state free precession (SSFP) sequence was simulated using matrix product operators. The simulations included the effects of flip angle (alpha), sequence timings, resonant frequency, gas diffusion coefficient, imaging gradients, T-1 and T-2. Experiments performed at 1.5 T, on gas phantoms and with healthy human subjects, confirm the predicted theory, and indicate increased SNR with SSFP through use of higher flip angles when compared to optimized spoiled gradient echo (SPGR). Simulations and experiments show some compromise to the SNR and some point spread function broadening at high g due to the incomplete refocusing of transverse magnetization, caused by diffusion dephasing from the readout gradient. Mixing of gas polarization levels by diffusion between slices is also identified as a source of signal loss in SSFP at higher a through incomplete refocusing. Nevertheless, in the sample experiments, a SSFP sequence with an optimized flip angle of alpha = 20 degrees, and 128 sequential phase encoding views, showed a higher SNR when compared to SPGR (alpha = 7.2 degrees) with the same bandwidth. Some of the gas sample experiments demonstrated a transient signal response that deviates from theory in the initial phase. This was identified as being caused by radiation clamping interactions between the large initial transverse magnetization and the high quality factor (Q = 250) birdcage resonator. In He-3 NMR experiments, performed without imaging gradients, diffusion dephasing can be mitigated, and the effective T, is relatively long (>= 1 s). Under these circumstances the SSFP sequence behaves like a CPMG sequence with sin(alpha/2) weighting of SNR. Experiments and simulations were also performed to characterize the off-resonance behaviour of the SSFP Hp He-3 signal. Characteristic banding artifacts due to off-resonance harmonic beating were observed in some of the in vivo SSFP images, for instance in axial slices close to the diaphragm where B-0 inhomogeneity is highest. Despite these artifacts, a higher SNR was observed with SSFP in vivo when compared to the SPGR sequence. The trends predicted by theory of increasing SSFP SNR with increasing flip angle were observed in the range alpha = 10-20 degrees without compromise to image quality through blurring caused by excessive k-space filtering. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:13 / 24
页数:12
相关论文
共 34 条
[1]
Nuclear magnetic resonance imaging of airways in humans with use of hyperpolarized He-3 [J].
Bachert, P ;
Schad, LR ;
Bock, M ;
Knopp, MV ;
Ebert, M ;
Grossmann, T ;
Heil, W ;
Hofmann, D ;
Surkau, R ;
Otten, EW .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) :192-196
[2]
RADIATION DAMPING IN MAGNETIC RESONANCE EXPERIMENTS [J].
BLOEMBERGEN, N ;
POUND, RV .
PHYSICAL REVIEW, 1954, 95 (01) :8-12
[3]
ANALYTICAL SOLUTION AND VERIFICATION OF DIFFUSION EFFECT IN SSFP [J].
CARNEY, CE ;
WONG, STS ;
PATZ, S .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :240-246
[4]
Lung air spaces:: MR imaging evaluation with hyperpolarized 3He gas [J].
de Lange, EE ;
Mugler, JP ;
Brookeman, JR ;
Knight-Scott, J ;
Truwit, JD ;
Teates, CD ;
Daniel, TM ;
Bogorad, PL ;
Cates, GD .
RADIOLOGY, 1999, 210 (03) :851-857
[5]
CPMG measurements and ultrafast imaging in human lungs with hyperpolarized helium-3 at low field (0.1 T). [J].
Durand, E ;
Guillot, G ;
Darrasse, L ;
Tastevin, G ;
Nacher, PJ ;
Vignaud, A ;
Vattolo, D ;
Bittoun, J .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :75-81
[6]
Nuclear magnetic resonance of laser-polarized noble gases in molecules, materials, and organisms [J].
Goodson, BM .
JOURNAL OF MAGNETIC RESONANCE, 2002, 155 (02) :157-216
[8]
Characterization and reduction of the transient response in steady-state MR imaging [J].
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :149-158
[9]
LEBIHAN D, 1989, MAGNET RESON MED, V10, P324
[10]
Gradient-echo imaging considerations for hyperpolarized Xe-129 MR [J].
Zhao, L ;
Mulkern, R ;
Tseng, CH ;
Williamson, D ;
Patz, S ;
Kraft, R ;
Walsworth, RL ;
Jolesz, FA ;
Albert, MS .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 113 (02) :179-183