Investigation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput liquid chromatography/tandem mass spectrometry assays

被引:36
作者
Yang, LY
Amad, M
Winnik, WM
Schoen, AE
Schweingruber, H
Mylchreest, I
Rudewicz, PJ
机构
[1] Schering Plough Corp, Inst Res, Kenilworth, NJ 07033 USA
[2] ThermoFinnigan, San Jose, CA 95134 USA
关键词
D O I
10.1002/rcm.824
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Triple quadrupole mass spectrometers, when operated in multiple reaction monitoring (MRM) mode, offer a unique combination of sensitivity, specificity, and dynamic range. Consequently, the triple quadrupole is the workhorse for high-throughput quantitation within the pharmaceutical industry. However, in the past, the unit mass resolution of quadrupole instruments has been a limitation when interference from matrix or metabolites cannot be eliminated. With recent advances in instrument design, triple quadrupole instruments now afford mass resolution of less than 0.1 Dalton (Da) full width at half maximum (FWHM). This paper describes the evaluation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput bioanalysis with emphasis on comparison of selectivity, sensitivity, dynamic range, precision, accuracy, and stability under both unit mass (1 Da FWHM) and enhanced (less than or equal to0.1 Da FWHM) resolution. The advantage of enhanced resolution was demonstrated in the case of mometasone with polypropylene glycol (PPG) interference. At unit mass resolution, the transmitted precursor ion from the first quadrupole contained not only protonated molecules from mometasone, but also PPG interference. At enhanced resolution only selected mometasone peaks were transmitted, and no interference from PPG was detected. Sensitivity of the instrument was demonstrated with 10 femtograms of descarboethoxyloratadine injected on-column, for which a signal-to-noise (S/N) ratio of 24 was obtained for MRM chromatograms at both unit and enhanced resolution. Absolute signals obtained at enhanced resolution were about one-third those obtained at unit mass resolution. However, S/N was maintained at enhanced resolution due to the proportional decrease in noise level. Finally, the stability of the instrument operating at enhanced resolution was demonstrated during an overnight 17 h period that was used to validate a liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay for the quantitation of loratadine and descarboethoxyloratadine in human plasma. Assay performances (dynamic range, correlation coefficients for standard curves, precision and accuracy for QC samples) under unit and enhanced resolution were both within current pharmaceutical and regulatory guidelines demonstrating the stability of the mass spectrometer operating at enhanced resolution for typical bioanalytical high-throughput applications. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:2060 / 2066
页数:7
相关论文
共 16 条
[1]  
Clauwaert KM, 1999, RAPID COMMUN MASS SP, V13, P1540, DOI 10.1002/(SICI)1097-0231(19990730)13:14<1540::AID-RCM688>3.0.CO
[2]  
2-1
[3]   An integrated ten-pump, eight-channel parallel LC/MS system for automated high-throughput analysis of proteins [J].
Feng, BB ;
McQueney, MS ;
Mezzasaima, TM ;
Slemmon, JR .
ANALYTICAL CHEMISTRY, 2001, 73 (23) :5691-5697
[4]   Simultaneous determination of a drug candidate and its metabolite in rat plasma samples using ultrafast monolithic column high-performance liquid chromatography/tandem mass spectrometry [J].
Hsieh, Y ;
Wang, GF ;
Wang, YG ;
Chackalamannil, S ;
Brisson, JM ;
Ng, K ;
Korfmacher, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (10) :944-950
[5]   Rapid, solid phase extraction technique for the high-throughput assay of darifenacin in human plasma [J].
Kaye, B ;
Herron, WJ ;
Macrae, PV ;
Robinson, S ;
Stopher, DA ;
Venn, RF ;
Wild, W .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1658-1660
[6]   A direct technique for the simultaneous determination of 10 drug candidates in plasma by liquid chromatography atmospheric pressure chemical ionization mass spectrometry interfaced to a Prospekt solid-phase extraction system [J].
McLoughlin, DA ;
Olah, TV ;
Gilbert, JD .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (12) :1893-1901
[7]   A 384-well solid-phase extraction for LC/MS/MS determination of methotrexate and its 7-hydroxy metabolite in human urine and plasma [J].
Rule, G ;
Chapple, M ;
Henion, J .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :439-443
[8]   Analysis and screening of combinatorial libraries using mass spectrometry [J].
Shin, YG ;
van Breemen, RB .
BIOPHARMACEUTICS & DRUG DISPOSITION, 2001, 22 (7-8) :353-372
[9]  
Siuzdak O, 1998, BIOTECHNOL BIOENG, V61, P127
[10]   LC/MS/MS analyses of an oleander extract for cancer treatment [J].
Wang, XM ;
Plomley, JB ;
Newman, RA ;
Cisneros, A .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3547-3552