Atmospheric pressure matrix-assisted laser desorption ionization as a plume diagnostic tool in laser evaporation methods

被引:5
作者
Callahan, JH
Galicia, MC
Vertes, A [1 ]
机构
[1] George Washington Univ, Dept Chem, Washington, DC 20052 USA
[2] USN, Res Lab, Chem Dynam & Diagnost Branch, Washington, DC 20375 USA
关键词
MAPLE; direct write; atmospheric pressure MALDI; laser evaporation; plume diagnostics;
D O I
10.1016/S0169-4332(02)00316-1
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Laser evaporation techniques, including matrix-assisted pulsed laser evaporation (MAPLE), are attracting increasing attention due to their ability to deposit thin layers of undegraded synthetic and biopolymers. Laser evaporation methods can be implemented in reflection geometry with the laser and the substrate positioned on the same side of the target. In some applications (e.g. direct write, DW), however, transmission geometry is used, i.e. the thin target is placed between the laser and the substrate. In this case, the laser pulse perforates the target and transfers some target material to the substrate. In order to optimize evaporation processes it is important to know the composition of the target plume and the material deposited from the plume. We used a recently introduced analytical method, atmospheric pressure matrix-assisted laser desorption ionization (AP-MALDI) to characterize the ionic components of the plume both in reflection and in transmission geometry. This technique can also be used to directly probe materials deposited on surfaces (such as glass slides) by laser evaporation methods. The test compound (small peptides, e.g. Angiotensin I, ATI or Substance P) was mixed with a MALDI matrix (alpha-cyano-4-hydroxycinnamic acid (CHCA), sinapinic acid (SA) or 2,5-dihydroxybenzoic acid (DHB)) and applied to the stainless steel (reflection geometry) or transparent conducting (transmission geometry) target holder. In addition to the classical dried droplet method, we also used electrospray target deposition to gain better control of crystallite size, thickness and homogeneity. The target was mounted in front of the inlet orifice of an ion trap mass spectrometer (IT-MS) that sampled the ionic components of the plume generated by a nitrogen laser. We studied the effect of several parameters, such as, the orifice to target distance, illumination geometry, extracting voltage distribution and sample preparation on the generated ions. Various analyte-matrix and matrix-matrix cluster ions were observed with relatively low abundance of the matrix ions. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:130 / 137
页数:8
相关论文
共 39 条
[31]   ANGULAR AND TIME-RESOLVED INTENSITY DISTRIBUTIONS OF LASER-DESORBED MATRIX IONS [J].
SPENGLER, B ;
BOKELMANN, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 82 (02) :379-385
[32]   COPLANAR MOLECULAR ASSEMBLIES OF AMINOALKYLSILANE AND PERFLUORINATED ALKYLSILANE - CHARACTERIZATION AND GEOMETRIC DEFINITION OF MAMMALIAN-CELL ADHESION AND GROWTH [J].
STENGER, DA ;
GEORGER, JH ;
DULCEY, CS ;
HICKMAN, JJ ;
RUDOLPH, AS ;
NIELSEN, TB ;
MCCORT, SM ;
CALVERT, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (22) :8435-8442
[33]  
TANG X, 1993, P 41 ASMS C MASS SPE, P666
[34]   MATRIX-ASSISTED LASER DESORPTION OF PEPTIDES IN TRANSMISSION GEOMETRY [J].
VERTES, A ;
BALAZS, L ;
GIJBELS, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (07) :263-266
[35]  
VERTES A, 1994, LASER ABLATION MECH, V2, P275
[36]   Dielectric properties of oxide structures by a laser-based direct-writing method [J].
Young, D ;
Wu, HD ;
Auyeung, RCY ;
Modi, R ;
Fitz-Gerald, J ;
Pique, A ;
Chrisey, DB ;
Atanassova, P ;
Kodas, T .
JOURNAL OF MATERIALS RESEARCH, 2001, 16 (06) :1720-1725
[37]   Time-resolved optical microscopy of a laser-based forward transfer process [J].
Young, D ;
Auyeung, RCY ;
Piqué, A ;
Chrisey, DB ;
Dlott, DD .
APPLIED PHYSICS LETTERS, 2001, 78 (21) :3169-3171
[38]   Exploring infrared wavelength matrix-assisted laser desorption/ionization of proteins with delayed-extraction time-of-flight mass spectrometry [J].
Zhang, WZ ;
Niu, SF ;
Chait, BT .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (09) :879-884
[39]   Diagnostic study of laser ablated YBa2Cu3Oy plumes [J].
Zheng, R ;
Campbell, M ;
Ledingham, KWD ;
Jia, W ;
Scott, CTJ ;
Singhal, RP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (03) :339-352