Randomized, non-inferiority trial of three limus agent-eluting stents with different polymer coatings: the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents (ISAR-TEST-4) Trial

被引:174
作者
Byrne, Robert A. [1 ]
Kastrati, Adnan [1 ]
Kufner, Sebastian [1 ]
Massberg, Steffen [1 ]
Birkmeier, K. Anette [1 ]
Laugwitz, Karl-Ludwig [2 ]
Schulz, Stefanie [1 ]
Pache, Juergen [1 ]
Fusaro, Massimiliano [1 ]
Seyfarth, Melchior [1 ]
Schoemig, Albert [1 ,2 ]
Mehilli, Julinda [1 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum, ISARes Ctr, D-80636 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Med Klin, D-80636 Munich, Germany
关键词
Biodegradable; Coronary restenosis; Drug-eluting stents; Polymer; Rapamycin; BARE-METAL STENTS; CORONARY-ARTERY-DISEASE; BIODEGRADABLE POLYMER; DURABLE POLYMER; SYSTEM; IMPLANTATION; METAANALYSIS; RESTENOSIS; REDUCTION; MULTIPLE;
D O I
10.1093/eurheartj/ehp352
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Although biodegradable polymer drug-eluting stent (DES) platforms have potential to enhance long-term clinical outcomes, data concerning their efficacy are limited to date. We previously demonstrated angiographic antirestenotic efficacy with a microporous, biodegradable polymer DES. In the current study, we hypothesized that at 12 months, its clinical safety and efficacy would be non-inferior to that of permanent polymer DES. Methods and results This prospective, randomized, open-label, active-controlled trial was conducted at two tertiary referral cardiology centres in Munich, Germany. Patients presenting with stable coronary disease or acute coronary syndromes undergoing DES implantation in de novo native-vessel coronary lesions were randomly assigned to treatment with biodegradable polymer DES (rapamycin-eluting; n = 1299) or permanent polymer DES (n = 1304: rapamycin-eluting, Cypher, n = 652; or everolimus-eluting, Xience, n = 652) and underwent clinical follow-up to 1 year. The primary endpoint was a composite of cardiac death, myocardial infarction (MI) related to the target vessel, or revascularization related to the target lesion (TLR). Biodegradable polymer DES was non-inferior to permanent polymer DES concerning the primary endpoint [13.8 vs. 14.4%, respectively, P(non-inferiority) 0.005; relative risk = 0.96 (95% confidence interval, 0.78-1.17), P(superiority) = 0.66]. Biodegradable polymer DES in comparison with permanent polymer DES showed similar rates of cardiac death or MI related to the target vessel (6.3 vs. 6.2%, P = 0.94), TLR (8.8 vs. 9.4%, P = 0.58), and stent thrombosis (definite/probable: 1.0 vs. 1.5%, P = 0.29). Subgroup analysis of the biodegradable polymer DES vs. individual Cypher and Xience stent arms revealed no signal of performance difference. Conclusion A biodegradable polymer rapamycin-eluting stent is non-inferior to permanent polymer-based DES in terms of clinical efficacy over 1 year. These results provide a framework for testing the potential clinical advantage of biodegradable polymer DES over the medium to long term.
引用
收藏
页码:2441 / 2449
页数:9
相关论文
共 41 条
[21]   Meta-analysis of randomized trials on drug-eluting stents vs. bare-metal stents in patients with acute myocardial infarction [J].
Kastrati, Adnan ;
Dibra, Alban ;
Spaulding, Christian ;
Laarman, Gerrit J. ;
Menichelli, Maurizio ;
Valgimigli, Marco ;
Di Lorenzo, Emilio ;
Kaiser, Christoph ;
Tierala, Ilkka ;
Mehilli, Julinda ;
Seyfarth, Melchior ;
Varenne, Olivier ;
Dirksen, Maurits T. ;
Percoco, Gianfranco ;
Varricchio, Attilio ;
Pittl, Undine ;
Syvanne, Mikko ;
Suttorp, Maarten J. ;
Violini, Roberto ;
Schoemig, Albert .
EUROPEAN HEART JOURNAL, 2007, 28 (22) :2706-2713
[22]   Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents [J].
Kastrati, Adnan ;
Mehilli, Julinda ;
Pache, Juergen ;
Kaiser, Christoph ;
Valgimigli, Marco ;
Kelbaek, Henning ;
Menichelli, Maurizio ;
Sabate, Manel ;
Suttorp, Maarten J. ;
Baumgart, Dietrich ;
Seyfarth, Melchior ;
Pfisterer, Matthias E. ;
Schoemig, Albert .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10) :1030-1039
[23]   Three-year follow-up after implantation of metallic coronary-artery stents [J].
Kimura, T ;
Yokoi, H ;
Nakagawa, Y ;
Tamura, T ;
Kaburagi, S ;
Sawada, Y ;
Sato, Y ;
Yokoi, H ;
Hamasaki, N ;
Nosaka, H ;
Nobuyoshi, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) :561-566
[24]   Safety and Efficacy of Drug-Eluting and Bare Metal Stents Comprehensive Meta-Analysis of Randomized Trials and Observational Studies [J].
Kirtane, Ajay J. ;
Gupta, Anuj ;
Iyengar, Srinivas ;
Moses, Jeffrey W. ;
Leon, Martin B. ;
Applegate, Robert ;
Brodie, Bruce ;
Hannan, Edward ;
Harjai, Kishore ;
Jensen, Lisette Okkels ;
Park, Seung-Jung ;
Perry, Raphael ;
Racz, Michael ;
Saia, Francesco ;
Tu, Jack V. ;
Waksman, Ron ;
Lansky, Alexandra J. ;
Mehran, Roxana ;
Stone, Gregg W. .
CIRCULATION, 2009, 119 (25) :3198-U78
[25]   Randomized trial of a nonpolymer-based rapamycin-eluting stent versus a polymer-based paclitaxel-eluting stent for the reduction of late lumen loss [J].
Mehilli, J ;
Kastrati, A ;
Wessely, R ;
Dibra, A ;
Hausleiter, J ;
Jaschke, B ;
Dirschinger, J ;
Schömig, A .
CIRCULATION, 2006, 113 (02) :273-279
[26]   Randomized trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis [J].
Mehilli, Julinda ;
Byrne, Robert A. ;
Wieczorek, Anna ;
Iijima, Raisuke ;
Schulz, Stefanie ;
Bruskina, Olga ;
Pache, Juergen ;
Wessely, Rainer ;
Schoemig, Albert ;
Kastrati, Adnan .
EUROPEAN HEART JOURNAL, 2008, 29 (16) :1975-1982
[27]   Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery [J].
Moses, JW ;
Leon, MB ;
Popma, JJ ;
Fitzgerald, PJ ;
Holmes, DR ;
O'Shaughnessy, C ;
Caputo, RP ;
Kereiakes, DJ ;
Williams, DO ;
Teirstein, PS ;
Jaeger, JL ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (14) :1315-1323
[28]   Biodegradable coating for drug-eluting stents -: more than a facelift? [J].
Niemela, Kari O. .
EUROPEAN HEART JOURNAL, 2008, 29 (16) :1930-1931
[29]   MAHOROBA, first-in-man study: 6-month results of a biodegradable polymer sustained release tacrolimus-eluting stent in de novo coronary stenoses [J].
Onuma, Yoshinobu ;
Serruys, Patrick ;
den Heijer, Peter ;
Joesoef, Kaiyum Sheik ;
Duckers, Henricus ;
Regar, Evelyn ;
Kukreja, Neville ;
Tanimoto, Shuzou ;
Garcia-Garcia, Hector M. ;
van Beusekom, Heleen ;
van der Giessen, Willem ;
Nishide, Takuji .
EUROPEAN HEART JOURNAL, 2009, 30 (12) :1477-1485
[30]   Reporting of noninferiority and equivalence randomized trials - An extension of the CONSORT Statement [J].
Piaggio, G ;
Elbourne, DR ;
Altman, DG ;
Pocock, SJ ;
Evans, SJW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (10) :1152-1160