An improved liquid chromatography/tandem mass spectrometry method for the determination of 8-oxo-7,8-dihydro-2′-deoxyguanosine in DNA samples using immunoaffinity column purification

被引:65
作者
Singh, R
McEwan, M
Lamb, JH
Santella, RM
Farmer, PB
机构
[1] Univ Leicester, Bioctr, Canc Biomarkers & Prevent Grp, Leicester LE1 7RH, Leics, England
[2] Oxford GlycoSci UK Ltd, Abingdon OX14 3YS, Oxon, England
[3] Columbia Univ, Mailman Sch Publ Hlth, Dept Environm Hlth Sci, New York, NY 10032 USA
关键词
D O I
10.1002/rcm.883
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) represents an important biomarker of oxidative stress. A sensitive method for the detection of 8-oxodG in DNA samples has been developed that utilizes immunoaffinity column purification of 8-oxodG followed by liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) multiple reaction monitoring (MRM) mode analysis. An internal standard of stable-isotopically labelled 8-oxodG containing [N-15(5)] was added prior to the enzymatic digestion of DNA to deoxynucleosides, which was then subjected to immunoaffinity column purification followed by microbore positive ion LC/MS/MS MRM. The 8-oxo-7,8-dihydroguanine (8-oxoG) base product ion at m/z 168 was monitored following cleavage of the glycosidic bond of the 8-oxodG [M+H](+) ion at m/z 284. Similar determinations were made for [N-15(5)]8-oxodG by monitoring the [N-15(5)]8-oxoG base product ion at m/z 173 formed from the [M+H](+) ion at m/z 289. The introduction of the immunoaffinity column purification step into the method represents a significant improvement for the accurate determination of 8-oxodG since all artefactual peaks that are observed following the direct injection of digested DNA onto the LC/MS/MS system are removed. The identity of these artefactual peaks has been confirmed to be 2'-deoxyguanosine (dG), thymidine (dT) and 2-deoxyadenosine (dA). The presence of these artefactual peaks in MRM mode analysis can be explained as a consequence of a concentration effect due to their considerably higher relative abundance in DNA compared to 8-oxodG. The highest signal intensity was observed for the artefactual peak for dA due to the fact that the adenine base formed an adduct with methanol, which is a constituent of the mobile phase. The resulting [M+H](+) ion at m/z 284 WA m/z 252 + CH3OH m/z 32) gave rise to a product ion at m/z 168 following the loss of deoxyribose in MRM mode analysis. Control calf thymus DNA was digested to deoxynucleosides and unmodfied deoxynucleosides were removed by immunoaffinity column purification; the enriched 8-oxodG was determined by LC/MS/MS MRM. The level of 8-oxodG in control calf thymus DNA was determined to be 28.8 +/- 1.2 8-oxodG per 10(6) unmodified nucleotides (n = 5) using 5 mug of digested DNA. The limit of detection of the microbore LC/MS/MS MRM for 8-oxodG was determined to be 25 fmol on-column with a signal-to-noise ratio of 3.5. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:126 / 134
页数:9
相关论文
共 33 条
[21]   Analysis of a form of oxidative DNA damage, 8-hydroxy-2′-deoxyguanosine, as a marker of cellular oxidative stress during carcinogenesis [J].
Kasai, H .
MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH, 1997, 387 (03) :147-163
[22]  
KVAM E, 1994, BBA-GENE STRUCT EXPR, V1217, P9
[23]  
Loft S, 1996, J MOL MED, V74, P297, DOI 10.1007/BF00207507
[24]   [32P]ATP mediates formation of 8-hydroxy-2′-deoxyguanosine from 2′-deoxyguanosine, a possible problem in the 32P-postlabeling assay [J].
Möller, L ;
Hofer, T .
CARCINOGENESIS, 1997, 18 (12) :2415-2419
[25]   QUANTITATIVE IMMUNOANALYSIS OF PROMUTAGENIC 8-HYDROXY-2'-DEOXYGUANOSINE IN OXIDIZED DNA [J].
MUSARRAT, J ;
WANI, AA .
CARCINOGENESIS, 1994, 15 (09) :2037-2043
[26]   DETECTION OF DNA ADDUCTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
PARK, JW ;
CUNDY, KC ;
AMES, BN .
CARCINOGENESIS, 1989, 10 (05) :827-832
[27]   Simultaneous measurement of 8-oxo-2′-deoxyguanosine and 8-oxo-2′-deoxyadenosine by HPLC-MS/MS [J].
Podmore, ID ;
Cooper, D ;
Evans, MD ;
Wood, M ;
Lunec, J .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2000, 277 (03) :764-770
[28]   DETERMINATION OF 8-OXOGUANINE IN DNA BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND HPLC-ELECTROCHEMICAL DETECTION - OVERESTIMATION OF THE BACKGROUND LEVEL OF THE OXIDIZED BASE BY THE GAS-CHROMATOGRAPHY MASS-SPECTROMETRY ASSAY [J].
RAVANAT, JL ;
TURESKY, RJ ;
GREMAUD, E ;
TRUDEL, LJ ;
STADLER, RH .
CHEMICAL RESEARCH IN TOXICOLOGY, 1995, 8 (08) :1039-1045
[29]   Isotope dilution high-performance liquid chromatography -: electrospray tandem mass spectrometry assay for the measurement of 8-oxo-7,8-dihydro-2′-deoxyguanosine in biological samples [J].
Ravanat, JL ;
Duretz, B ;
Guiller, A ;
Douki, T ;
Cadet, J .
JOURNAL OF CHROMATOGRAPHY B, 1998, 715 (02) :349-356
[30]   Comparative analysis of 8-oxo-2′-deoxyguanosine in DNA by 32P- and 33P-postlabeling and electrochemical detection [J].
Schuler, D ;
Otteneder, M ;
Sagelsdorff, P ;
Eder, E ;
Gupta, RC ;
Lutz, WK .