Comparison of GFR Measurements Assessed From Single Versus Multiple Samples

被引:42
作者
Bird, Nicholas J. [1 ]
Peters, Christina [1 ]
Michell, A. Robert [2 ]
Peters, A. Michael [1 ]
机构
[1] Addenbrookes Hosp, Dept Nucl Med, Cambridge CB2 2QQ, England
[2] St Bartholomews Med Sch, Dept Biochem Pharmacol, William Harvey Res Inst, London, England
关键词
Glomerular filtration rate; chromium-51 (Cr-51)-EDTA; iohexol; single sample; validation; GLOMERULAR-FILTRATION-RATE; PLASMA-CLEARANCE METHOD; NONRADIOACTIVE IOHEXOL; SLOPE-INTERCEPT; INJECTION; ADULTS; TECHNETIUM-99M-DTPA; CHROMIUM-51-EDTA; CR-51-EDTA;
D O I
10.1053/j.ajkd.2009.03.026
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Many previous studies have evaluated single-sample glomerular filtration rate (GFR) against multisample GFR, of which the single sample was a member, but none have compared single and multisample GFRs against an independent reference method. We therefore performed this comparison by using simultaneous independent multisample GFR measured with a different indicator. Setting & Participants: University hospital: patients and healthy volunteers (95 studies in 60 patients and 20 healthy participants). Healthy volunteers were studied fasting and after food; 10 of them had a repeated fasting study. Study Design: Diagnostic test study. Index Test: Single-sample GFR. Reference Test: Multisample GFR with a different indicator. Measurements: GFR was measured by using chromium-51 (Cr-51)-EDTA and iohexol, injected into opposite arms and scaled to 1.73 m(2). Blood samples, obtained bilaterally 20, 40, 60, 120, 180, and 240 minutes after injection, were assayed for indicator injected contralaterally. Single-sample GFR (Jacobsson method) was calculated from indicator concentrations at 3 and 4 hours. Single-sample GFR from 1 indicator was compared with multisample GFR from the other and vice versa, as well as from the same indicator. Differences were expressed as limits of agreement between paired measurements in Bland-Altman plots. Precision was expressed as the SD of the mean difference between paired measurements. Results: Limits of agreement between multisample GFRs measured by using Cr-51-EDTA and iohexol (-12 to 20 mL/min) were similar to the corresponding limits for single-sample GFR at 3 (-16 to 17 mL/min) and 4 hours (-11 to 17 mL/min). The precision of single-sample GFR at 4 hours by using Cr-51-EDTA for predicting iohexol multisample GFR (6.9 mL/min) was better than that of multisample GFR with Cr-51-EDTA (7.9 mL/min). When analysis was limited to patients with GFR less than 60 mL/min, single-sample GFR was slightly inferior to multisample GFR. In healthy participants, single-sample GFR with Cr-51-EDTA at 3 and 4 hours showed repeatability (SD of change, 9.4 and 9.3 mL/min) similar to multisample GFR with Cr-51-EDTA (10.7 mL/min). Single-sample GFR at 4 hours by using Cr-51-EDTA detected a food-induced increase in GFR (4.4 +/- 5.9 mL/min; P < 0.001) with more confidence than multisample GFR by using Cr-51-EDTA (4.6 +/- 7.5 mL/min; P < 0.01). Limitations: No separate gold standard (eg, inulin) to facilitate interpretation of observed differences between 2 markers. Conclusions: Single-sample GFR is as reliable as multisample GFR for measuring GFR, especially when GFR is greater than 60 mL/min. Am J Kidney Dis 54:278-288. (C) 2009 by the National Kidney Foundation, Inc.
引用
收藏
页码:278 / 288
页数:11
相关论文
共 30 条
[1]  
ALTMAN DG, 1991, PRACTICAL STAT MED R, P269
[2]   Suitability of a simplified technique based on iohexol for decentralized measurement of glomerular filtration rate [J].
Bird, Nicholas J. ;
Peters, Christina ;
Michell, A. Robert ;
Peters, A. Michael .
SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2008, 42 (05) :472-480
[3]   Reproducibilities and responses to food intake of GFR measured with chromium-51-EDTA and iohexol simultaneously and independently in normal subjects [J].
Bird, Nicholas J. ;
Peters, Christina ;
Michell, A. Robert ;
Peters, A. Michael .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2008, 23 (06) :1902-1909
[4]   Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate [J].
Bird, Nicholas J. ;
Peters, Christina ;
Michell, A. Robert ;
Peters, A. Michael .
NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (12) :1086-1092
[5]   GFR measurement with iohexol and 51Cr-EDTA.: A comparison of the two favoured GFR markers in Europe [J].
Brandstrom, E ;
Grzegorczyk, A ;
Jacobsson, L ;
Friberg, P ;
Lindahl, A ;
Aurell, M .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (05) :1176-1182
[6]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[7]   LIMITATIONS OF SINGLE SAMPLE TRACER METHOD FOR DETERMINING GLOMERULAR-FILTRATION RATE [J].
CHATTERTON, BE .
BRITISH JOURNAL OF RADIOLOGY, 1978, 51 (612) :981-985
[8]   SINGLE SAMPLE ESTIMATES OF RENAL CLEARANCES [J].
CONSTABLE, AR ;
HUSSEIN, MM ;
ALBRECHT, MP ;
THOMPSON, FD ;
PHILALITHIS, PE ;
JOEKES, AM .
BRITISH JOURNAL OF UROLOGY, 1979, 51 (02) :84-87
[9]   Comparative microvascular exchange kinetics of [77Br]bromide and 99mTc-DTPA in humans [J].
Cousins, C ;
Skehan, SJ ;
Rolph, SM ;
Flaxman, ME ;
Ballinger, JR ;
Bird, NJ ;
Barber, RW ;
Peters, AM .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (05) :655-662
[10]   Post-test quality control for the single blood sample technique in glomerular filtration rate measurement in children [J].
De Sadeleer, C ;
Piepsz, A ;
Ham, HR .
NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (03) :255-260