Comparison of two automated DNA amplification systems with a manual one-tube nested PCR assay for diagnosis of pulmonary tuberculosis

被引:61
作者
Yuen, KY
Yam, WC
Wong, LP
Seto, WH
机构
关键词
POLYMERASE CHAIN-REACTION; MYCOBACTERIUM-TUBERCULOSIS; SPECIMENS;
D O I
10.1128/JCM.35.6.1385-1389.1997
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Eighty-four specimens of respiratory secretions culture positive for mycobacteria (70 positive for Mycobacterium tuberculosis and 14 positive for nontuberculous mycobacteria) and 120 culture-negative specimens were evaluated by three DNA amplification techniques: a manual in-house single-tube nested PCR (nPCR) and two commercial automated assays (the Cobas Amplicor System [aPCR-h] from Roche Diagnostic Systems and the Abbott LCx Probe System [aLCx-p] from Abbott Laboratories), The overall diagnostic sensitivities of the nPCR, aPCR-h, and aLCx-p were 77.1, 84.3, and 77.1%, respectively, and the sensitivities were 57.9, 57.9, and 36.8%, respectively, for smear-negative specimens, Specimens culture positive for nontuberculous mycobacteria were negative by all three assays, Eight culture-negative specimens which were positive by one or more assays had previously been documented by culture to be positive for M., tuberculosis and were taken from patients who were treated with antituberculosis agents, Retesting of specimens negative by one assay by the other two assays revealed that each test had its unique group of negative specimens, When considering the DNA extraction and amplification steps of these assays separately, it was found that extracts from aPCR-h and aLCx-p were compatible with nPCR amplication, while the two automated assays could only amplify extracts processed with their own reagents, Limiting dilution analysis revealed that the order of analytical sensitivity was nPCR, followed by aLCx-p and then aPCR-h, Comparison of the work Bow of each assay revealed that although the aPCR-h demands the least specimen handling, the turnaround time of aLCx-p is the most favorable.
引用
收藏
页码:1385 / 1389
页数:5
相关论文
共 10 条
[1]   EVALUATION OF AMPLICOR PCM FOR DIRECT-DETECTION OF MYCOBACTERIUM-TUBERCULOSIS FROM SPUTUM SPECIMENS [J].
BEAVIS, KG ;
LICHTY, MB ;
JUNGKIND, DL ;
GIGER, O .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (10) :2582-2586
[2]   SCREENING OF RESPIRATORY-TRACT SPECIMENS FOR THE PRESENCE OF MYCOBACTERIUM-TUBERCULOSIS BY USING THE GEN-PROBE AMPLIFIED MYCOBACTERIUM-TUBERCULOSIS DIRECT TEST [J].
BODMER, T ;
GURTNER, A ;
SCHOPFER, K ;
MATTER, L .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (06) :1483-1487
[3]   Single-tube nested PCR in the diagnosis of tuberculosis [J].
Chan, CM ;
Yuen, KY ;
Chan, KS ;
Yam, WC ;
Yim, KHM ;
Ng, WF ;
Ng, MH .
JOURNAL OF CLINICAL PATHOLOGY, 1996, 49 (04) :290-294
[4]   LARGE-SCALE USE OF POLYMERASE CHAIN-REACTION FOR DETECTION OF MYCOBACTERIUM-TUBERCULOSIS IN A ROUTINE MYCOBACTERIOLOGY LABORATORY [J].
CLARRIDGE, JE ;
SHAWAR, RM ;
SHINNICK, TM ;
PLIKAYTIS, BB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (08) :2049-2056
[5]  
*DEP HLTH HONG KON, 1996, PUBLIC HLTH EP B, V5, P6
[6]  
DOUGLAS FM, 1996, J CLIN MICROBIOL, V34, P1745
[7]   DIRECT-DETECTION OF MYCOBACTERIUM-TUBERCULOSIS IN RESPIRATORY SPECIMENS IN A CLINICAL LABORATORY BY POLYMERASE CHAIN-REACTION [J].
FORBES, BA ;
HICKS, KES .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (07) :1688-1694
[8]   EVALUATION OF GEN-PROBE AMPLIFIED MYCOBACTERIUM-TUBERCULOSIS DIRECT TEST AND PCR FOR DIRECT-DETECTION OF MYCOBACTERIUM-TUBERCULOSIS IN CLINICAL SPECIMENS [J].
MILLER, N ;
HERNANDEZ, SG ;
CLEARY, TJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (02) :393-397
[9]   PHENOLIC ACRIDINE-ORANGE FLUORESCENT STAIN FOR MYCOBACTERIA [J].
SMITHWICK, RW ;
BIGBIE, MR ;
FERGUSON, RB ;
KARLIX, MA ;
WALLIS, CK .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (10) :2763-2764
[10]   Comparison of fluorescent BACTEC 9000 MB system, Septi-Chek AFB system, and Lowenstein-Jensen medium for detection of mycobacteria [J].
vanGriethuysen, AJ ;
Jansz, AR ;
Buiting, AGM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (10) :2391-2394