Comparison of dose response of radiochromic film measured with He-Ne laser, broadband, and filtered light densitometers

被引:31
作者
Reinstein, LE
Gluckman, GR
机构
[1] Department of Radiation Oncology, SUNY at Stony Brook, Stony Brook
关键词
radiochromic film; densitometer; film; GAFChromic film;
D O I
10.1118/1.598043
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dose response curves for GAFChromic MD-55-2 film were measured using three different densitometer systems: a He-Ne laser densitometer, a broadband (white light) densitometer, and a filtered red light densitometer. These were found to differ significantly; the dose needed to achieve a net optical density of 1 (DNOD1) was greater than 100 Gy for the white light densitometer, 56 Gy for the He-Ne densitometer, and only 14.8 Cy for the filtered red Light densitometer. This represents approximately a fourfold increase in response for the filtered red light versus the He-Ne laser densitometer, which is a significant improvement. For some patient prescriptions this enables us to achieve an accuracy and precision sufficient to verify daily dose to within 5%. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1531 / 1533
页数:3
相关论文
共 12 条
[1]   HIGH-SENSITIVITY GAFCHROMIC FILM DOSIMETRY FOR I-125 SEED [J].
CHIUTSAO, ST ;
DELAZERDA, A ;
LIN, J ;
KIM, JH .
MEDICAL PHYSICS, 1994, 21 (05) :651-657
[2]  
CHU RDH, 1990, RADIAT PHYS CHEM, V35, P767
[3]   MEASUREMENT OF ABSORBED DOSE AND DOSE GRADIENTS [J].
MCLAUGHLIN, WL .
RADIATION PHYSICS AND CHEMISTRY, 1980, 15 (01) :9-38
[4]   RESPONSE OF PLASTIC DOSIMETERS TO GAMMA-RAYS AND ELECTRONS AT HIGH ABSORBED DOSE-RATES [J].
MCLAUGHLIN, WL ;
HUMPHREYS, JC ;
RADAK, BB ;
MILLER, A ;
OLEJNIK, TA .
RADIATION PHYSICS AND CHEMISTRY, 1979, 14 (3-6) :535-550
[5]   THE USE OF A RADIOCHROMIC DETECTOR FOR THE DETERMINATION OF STEREOTAXIC RADIOSURGERY DOSE CHARACTERISTICS [J].
MCLAUGHLIN, WL ;
SOARES, CG ;
SAYEG, JA ;
MCCULLOUGH, EC ;
KLINE, RW ;
WU, A ;
MAITZ, AH .
MEDICAL PHYSICS, 1994, 21 (03) :379-388
[6]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176
[7]   Dosimetric characteristics of an improved radiochromic film [J].
Meigooni, AS ;
Sanders, MF ;
Ibbott, GS ;
Szeglin, SR .
MEDICAL PHYSICS, 1996, 23 (11) :1883-1888
[8]  
MEIGOONI AS, 1993, MED PHYS, V20, P1298
[9]  
Mishra V, 1993, MED PHYS, V20, P865
[10]   PHOTON ENERGY-DEPENDENCE OF THE SENSITIVITY OF RADIOCHROMIC FILM AND COMPARISON WITH SILVER-HALIDE FILM AND LIF TLDS USED FOR BRACHYTHERAPY DOSIMETRY [J].
MUENCH, PJ ;
MEIGOONI, AS ;
NATH, R ;
MCLAUGHLIN, WL .
MEDICAL PHYSICS, 1991, 18 (04) :769-775