High-throughput positive-dielectrophoretic bioparticle microconcentrator

被引:69
作者
Gadish, Nitzan [1 ]
Voldman, Joel [1 ]
机构
[1] MIT, Dept Elect & Comp Sci, Cambridge, MA 02139 USA
关键词
D O I
10.1021/ac061170i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We introduce a new dielectrophoretic particle microconcentrator that combines interdigitated electrodes with a chaotic mixer to achieve high-throughput (> 100 mu L/min) particle concentration. The interdigitated electrodes use positive dielectrophoresis to attract particles to the surface, while the chaotic mixer circulates the particles to increase the number brought in proximity with the surface. We have used this microconcentrator to concentrate both beads and B. subtilis spores and have developed a microvolume concentration measurement method to determine the delivered off-chip concentration enhancement of the output sample. The resulting microconcentrator is sufficiently high throughput to serve as an interface between macroscale sample collectors and micro- or nanoscale detectors.
引用
收藏
页码:7870 / 7876
页数:7
相关论文
共 31 条
[1]   Geometric and material determinants of patterning efficiency by dielectrophoresis [J].
Albrecht, DR ;
Sah, RL ;
Bhatia, SN .
BIOPHYSICAL JOURNAL, 2004, 87 (04) :2131-2147
[2]   Superpositioned dielectrophoresis for enhanced trapping efficiency [J].
Aldaeus, F ;
Lin, Y ;
Roeraade, J ;
Amberg, G .
ELECTROPHORESIS, 2005, 26 (22) :4252-4259
[3]  
Belgrader P, 2001, ANAL CHEM, V73, P286, DOI 10.1021/ac000905v
[4]   Closed-form solutions in the electrical field analysis for dielectrophoretic and travelling wave inter-digitated electrode arrays [J].
Chang, DE ;
Loire, S ;
Mezic, I .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (23) :3073-3078
[5]   Membrane-based on-line optical analysis system for rapid detection of bacteria and spores [J].
Floriano, PN ;
Christodoulides, N ;
Romanovicz, D ;
Bernard, B ;
Simmons, GW ;
Cavell, M ;
McDevitt, JT .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2079-2088
[6]   Microbiological safety of drinking water: United States and global perspectives [J].
Ford, TE .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 :191-206
[7]   A silicon microfluidic ultrasonic separator [J].
Harris, NR ;
Hill, M ;
Beeby, S ;
Shen, Y ;
White, NM ;
Hawkes, JJ ;
Coakley, WT .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 95 (1-3) :425-434
[8]   ELECTRODE DESIGN FOR NEGATIVE DIELECTROPHORESIS [J].
HUANG, Y ;
PETHIG, R .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (12) :1142-1146
[9]   Introducing dielectrophoresis as a new force field for field-flow fractionation [J].
Huang, Y ;
Wang, XB ;
Becker, FF ;
Gascoyne, PRC .
BIOPHYSICAL JOURNAL, 1997, 73 (02) :1118-1129
[10]   Manipulation of herpes simplex virus type 1 by dielectrophoresis [J].
Hughes, MP ;
Morgan, H ;
Rixon, FJ ;
Burt, JPH ;
Pethig, R .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 1998, 1425 (01) :119-126