Facts and myths about columns packed with sub-3 μm and sub-2 μm particles

被引:41
作者
Fekete, Szabolcs [1 ]
Ganzler, Katalin [1 ]
Fekete, Jeno [2 ]
机构
[1] Gedeon Richter Plc, Formulat Dev, Budapest, Hungary
[2] Budapest Univ Technol & Econ, Dept Inorgan & Analyt Chem, H-1111 Budapest, Hungary
关键词
Fast chromatography; Sub-2 micron particles; Kinetic efficiency; Poppe plot; Low- and high-molecular weight test compounds; PERFORMANCE LIQUID-CHROMATOGRAPHY; ULTRA-HIGH-PRESSURE; PHARMACEUTICAL DEVELOPMENT; TEMPERATURE PROFILES; PRACTICAL ASPECTS; GRADIENT ELUTION; PART I; SPEED; EFFICIENCY; SIZE;
D O I
10.1016/j.jpba.2009.08.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Increasing the separating efficiency enhances the separation power. The most popular solution for improving chromatographic performance is to employ columns packed with small particle diameters (i.e., sub-2 mu m particles) to induce a simultaneous improvement in efficiency, optimal velocity and mass transfer, albeit the cost of pressure. In this study a systematic evaluation of the possibilities and limitations of the separations obtained with 5 cm long narrow bore columns packed with 1.5-3.0 mu m particles is presented. Several commercially available different sub-3 mu m and sub-2 mu m packed columns were evaluated by using van Deemter, Knox and kinetic plots. Theoretical Poppe plots were constructed for each column to compare their kinetic performance. Data are presented on different polar neutral real life analytes, to show that the separation time is not obviously shorter if the particle size is reduced. Comparison of low-molecular weight compounds (one steroid and one non-steroid hormone, with molecular weights lower than 500) and a high-molecular weight one (MW similar to 1000) was conducted. Same efficiency can be achieved with columns packed with 1.9-2.1 mu m particles as with smaller particles. The column packed with 3 mu m particles had the lowest reduced plate height minimum (h = 2.2) while the column with the smallest particles (1.5 mu m) gave the highest reduced plate height minimum (h similar to 3.0). According to this study, the theoretically expected efficiency of very fine particles (diameter <2 mu m) used in practice today is compromised. Investigation of this phenomenon is presented. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 64
页数:9
相关论文
共 40 条
[1]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[2]   HIGH-SPEED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS [J].
CHEN, H ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) :3-20
[3]   Evaluation and comparison of very high pressure liquid chromatography systems for the separation and validation of pharmaceutical compounds [J].
Cunliffe, Jennifer M. ;
Adams-Hall, Sharee B. ;
Maloney, Todd D. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (08) :1214-1223
[4]   Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1 mm ID columns [J].
de Villiers, A ;
Lauer, H ;
Szucs, R ;
Goodall, S ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1113 (1-2) :84-91
[5]   Evaluation of ultra performance liquid chromatography -: Part I.: Possibilities and limitations [J].
de Villiers, Andre ;
Lestremau, Francois ;
Szucs, Roman ;
Gelebart, Sylvie ;
David, Frank ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) :60-69
[6]   Effect of analyte properties on the kinetic performance of liquid chromatographic separations [J].
de Villiers, Andre ;
Lynen, Frederic ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (16) :3431-3442
[7]  
Desmet G, 2008, LC GC EUR, V21, P310
[8]   Future of high pressure liquid chromatography: Do we need porosity or do we need pressure? [J].
Desmet, Gert ;
Cabooter, Deirdre ;
Gzil, Piotr ;
Verelst, Harry ;
Mangelings, Debby ;
Vander Heyden, Yvan ;
Clicq, David .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1130 (01) :158-166
[9]   Characteristics of superficially-porous silica particles for fast HPLC:: Some performance comparisons with sub-2-μm particles [J].
DeStefano, J. J. ;
Langlois, T. J. ;
Kirkland, J. J. .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (03) :254-260
[10]   Characterization of new types of stationary phases for fast liquid chromatographic applications [J].
Fekete, Szabolcs ;
Fekete, Jeno ;
Ganzler, Katalin .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) :703-709