A New Transcutaneous Energy Transmission System With Hybrid Energy Coils for Driving an Implantable Biventricular Assist Device

被引:25
作者
Okamoto, Eiji [1 ]
Yamamoto, Yoshiro [2 ]
Akasaka, Yuhta
Motomura, Tadashi [3 ]
Mitamura, Yoshinori
Nose, Yukihiko [3 ]
机构
[1] Tokai Univ, Dept Human Sci & Informat, Minami Ku, Sapporo, Hokkaido 0058601, Japan
[2] Miwatec Ltd Co, Tokyo, Japan
[3] Baylor Coll Med, Houston, TX 77030 USA
关键词
Artificial heart; Ventricular assist device; Energy transmission; Transcutaneous energy transmission;
D O I
10.1111/j.1525-1594.2009.00785.x
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
We have developed a new transcutaneous energy transmission (TET) system for a totally implantable biventricular assist device(BVAD) system in the New Energy and Industrial Development Organization (NEDO) artificial heart project. The TET system mainly consists of an energy transmitter, a hybrid energy coil unit, an energy receiver, an internal battery system, and an optical telemetry system. The hybrid energy coil unit consists of an air-core energy transmission coil and an energy-receiving coil having a ferrite core. Internal units of the TET system are encapsulated in a titanium alloy casing, which has a size of 111 mm in width, 73 mm in length, and 25 mm in height. In in vitro experiments, the TET system can transmit a maximum electric energy of 60 Watts, and it has a maximum transmission efficiency of 87.3%. A maximum surface temperature of 46.1 degrees C was measured at the ferrite core of the energy-receiving coil during an energy transmission of 20 Watts in air. The long-term performance test shows that the TET system has been able to operate stably for over 4 years with a decrease of energy-transmission efficiency from 85% to 80%. In conclusion, the TET system with the hybrid energy coil can overcome the drawback of previously reported TET systems, and it promises to be the highest performance TET system in the world.
引用
收藏
页码:622 / 626
页数:5
相关论文
共 11 条
[1]
The AbioCor implantable replacement heart [J].
Dowling, RD ;
Gray, LA ;
Etoch, SW ;
Laks, H ;
Marelli, D ;
Samuels, L ;
Ebtwhistle, J ;
Couper, G ;
Vlahakes, GJ ;
Frazier, OH .
ANNALS OF THORACIC SURGERY, 2003, 75 (06) :S93-S99
[2]
MITAMURA Y, 1989, ASSISTED CIRCULATION, V3, P569
[3]
A synchronous rectification using a digital PLL technique for contactless power supplies [J].
Miura, H ;
Arai, S ;
Sato, F ;
Matsuki, H ;
Sato, T .
IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (10) :3997-3999
[4]
Ten-year NEDO BVAD development program:: Moving forward to the clinical arena [J].
Motomura, Tadashi ;
Okubo, Hisashi ;
Oda, Takeshi ;
Ogawa, Daisuke ;
Okahisa, Toshiya ;
Igo, Stephen ;
Shinohara, Toshiyuki ;
Yamamoto, Yoshiro ;
Noguchi, Chikaya ;
Ishizuka, Tsukasa ;
Okamoto, Eiji ;
Nose, Yukihiko .
ASAIO JOURNAL, 2006, 52 (04) :378-385
[5]
Development of integrated electronics unit for drive and control of undulation pump-left ventricular assist device [J].
Okamoto, E ;
Makino, T ;
Inoue, Y ;
Tanaka, S ;
Yasuda, T ;
Nakamura, M ;
Saito, I ;
Abe, Y ;
Chinzei, T ;
Isoyama, T ;
Mochiizuki, S ;
Imachi, K ;
Mitamura, Y .
ARTIFICIAL ORGANS, 2006, 30 (05) :403-405
[6]
OKAMOTO E, 1991, ARTIFICIAL HEART, V3, P197
[7]
Development of a bidirectional transcutaneous optical data transmission system for artificial hearts allowing long-distance data communication with low electric power consumption [J].
Okamoto E. ;
Yamamoto Y. ;
Inoue Y. ;
Makino T. ;
Mitamura Y. .
Journal of Artificial Organs, 2005, 8 (3) :149-153
[8]
Recent progress on transcutaneous energy transfer for total artificial heart systems [J].
Puers, R ;
Vandevoorde, G .
ARTIFICIAL ORGANS, 2001, 25 (05) :400-405
[9]
ROSENBERG G, 1995, ASSISTED CIRCULATION, V4, P236
[10]
A transcutaneous energy transmission system with rechargeable internal back-up battery for a totally implantable total artificial heart [J].
Shiba, K ;
Shu, EM ;
Koshiji, K ;
Tsukahara, K ;
Nakamura, T ;
Masuzawa, T ;
Tatsumi, E ;
Taenaka, Y ;
Takano, H .
ASAIO JOURNAL, 1999, 45 (05) :466-470