摘要
Reversed-phase separations provides a versatile technique in high-performance liquid chromatography. Porous graphitized carbon (PGC) support shows unique retention characteristics. Separations on PGC columns use typical reversed-phase eluents (water and organic modifiers miscible with water), however, the retention order of solutes generally does not follow their hydrophobicity order. Molecular hydrophobicity influences but not determines the elution order of any set of solutes. The properties of these supports, mechanisms of retention and application are discussed, along with correlations which can guide the choice of solvent combinations for typical separations. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:229 / 243
页数:15
相关论文
共 53 条
[11]   Separation of oligomers of nonylphenylethylene oxide on a porous graphitized carbon column [J].
Cserhati, T ;
Forgacs, E ;
Szilagyi, A .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (9-10) :1303-1307
[12]  
DICORCIA A, 1976, ADV CHROMATOGR, V14, P305
[13]   Porous graphitized carbon and octadecyl-silica columns in the separation of some alkylglycoside detergents [J].
Elfakir, C ;
Lafosse, M .
JOURNAL OF CHROMATOGRAPHY A, 1997, 782 (02) :191-198
[14]   SEPARATION OF CATIONIC TECHNETIUM-99M AMINE COMPLEXES ON POROUS GRAPHITIC CARBON [J].
EMERY, MF ;
LIM, CK .
JOURNAL OF CHROMATOGRAPHY, 1989, 479 (01) :212-215
[15]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF GLYCOPEPTIDES AND OLIGOSACCHARIDES ON GRAPHITIZED CARBON COLUMNS [J].
FAN, JQ ;
KONDO, A ;
KATO, I ;
LEE, YC .
ANALYTICAL BIOCHEMISTRY, 1994, 219 (02) :224-229
[16]   RETENTION OF SOME RING-SUBSTITUTED ANILINE DERIVATIVES BY POROUS GRAPHITIZED CARBON - DEPENDENCE ON PHYSICOCHEMICAL PARAMETERS [J].
FORGACS, E ;
CSERHATI, T .
CHROMATOGRAPHIA, 1992, 33 (7-8) :356-360
[17]   Use of principal component analysis for the study of the influence of physicochemical parameters on the retention of barbiturates on porous graphitized carbon column [J].
Forgacs, E ;
Cserhati, T .
ANALYTICAL SCIENCES, 1998, 14 (05) :991-996
[18]   Use of cluster and principal component analysis in quantitative structure-retention relationship study [J].
Forgacs, E ;
Cserhati, T .
ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) :481-487
[19]   Relationship between retention characteristics and physicochemical parameters of solutes on porous graphitized carbon column [J].
Forgács, E ;
Cserháti, T .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) :505-510
[20]   DEPENDENCE OF THE RETENTION OF SOME BARBITURIC-ACID DERIVATIVES ON A POROUS GRAPHITIZED CARBON COLUMN ON THEIR PHYSIOCHEMICAL PARAMETERS [J].
FORGACS, E ;
CSERHATI, T .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (10-12) :861-865