Quantitative determination of semivolatile organic compounds in solution using trap-and-release membrane inlet mass spectrometry

被引:53
作者
Lauritsen, FR
Ketola, RA
机构
[1] Physical Biochemistry Group, Institute of Biochemistry, Odense University
[2] VTT Chemical Technology, FIN-02044 VTT
关键词
D O I
10.1021/ac970570q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper discusses the use of trap-and-release membrane inlet mass spectrometry (T&R-MIMS) for the quantitative determination of semivolatile organic compounds in real samples. We found that the T&R-MIMS technique is particular sensitive to relatively polar, semivolatile organic compounds, For example, the detection limits for the acids acetylsalicylic acid and phenoxyacetic acid were lowered by a factor of 100 as compared with those possible with standard MIMS, and caffeine was detectable only with the T&R-MIMS method, The detection limits were in the parts-per-billion range, and the dynamic range was 3 orders of magnitude, As a practical example of the application of the T&R-MIMS technique, we used it for the quantitative analysis of caffeine in ground coffee and tea leaves. Good agreement between T&R-MIMS and HPLC determinations was found, and the reproducibility of the whole analytical system for caffeine determination (extraction procedure and T&R-MIMS determination) was within 10% as relative standard deviation. However, for coffee, a large background from the essential oils prevented low-level work, such as the determination of residual caffeine in decaffeinated coffee, Obviously, the analysis of many complex matrixes will require the use of tandem mass spectrometry.
引用
收藏
页码:4917 / 4922
页数:6
相关论文
共 29 条
[1]   MICROPORE MEMBRANE INLET MASS-SPECTROMETER PROBES SUITABLE FOR MEASUREMENT OF TISSUE SURFACE GAS TENSIONS [J].
BAUMGARDNER, JE ;
QUINN, JA ;
NEUFELD, GR .
JOURNAL OF MASS SPECTROMETRY, 1995, 30 (04) :563-571
[2]   MEMBRANE INTERFACE FOR SELECTIVE INTRODUCTION OF VOLATILE COMPOUNDS DIRECTLY INTO THE IONIZATION-CHAMBER OF A MASS-SPECTROMETER [J].
BIER, ME ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :597-601
[3]   DIRECT INSERTION MEMBRANE PROBE FOR SELECTIVE INTRODUCTION OF ORGANIC-COMPOUNDS INTO A MASS-SPECTROMETER [J].
BIER, ME ;
KOTIAHO, T ;
COOKS, RG .
ANALYTICA CHIMICA ACTA, 1990, 231 (02) :175-190
[4]   HPLC DETERMINATION OF CAFFEINE AND THEOBROMINE IN COFFEE, TEA, AND INSTANT HOT COCOA MIXES [J].
BLAUCH, JL ;
TARKA, SM .
JOURNAL OF FOOD SCIENCE, 1983, 48 (03) :745-&
[5]   Analysis ob polar organic compounds using charge exchange ionization and membrane introduction mass spectrometry [J].
Cisper, ME ;
Garrett, AW ;
Cameron, D ;
Hemberger, PH .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2097-2101
[6]  
COOKS RG, 1992, ACS SYM SER, V508, P126
[7]   MEMBRANE INLET MASS-SPECTROMETRY IN PURE AND APPLIED MICROBIOLOGY [J].
DEGN, H .
JOURNAL OF MICROBIOLOGICAL METHODS, 1992, 15 (03) :185-197
[8]  
DEGN H, 1992, BIOTECHNOL TECH, V6, P161
[9]   JET SEPARATOR MEMBRANE INTRODUCTION MASS-SPECTROMETRY FOR ONLINE QUANTITATION OF VOLATILE ORGANIC-COMPOUNDS IN AQUEOUS-SOLUTIONS [J].
DEJARME, LE ;
BAUER, SJ ;
COOKS, RG ;
LAURITSEN, FR ;
KOTIAHO, T ;
GRAF, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) :935-942
[10]  
Gordon SM, 1996, RAPID COMMUN MASS SP, V10, P1038