Peripheral arterial disease: Gadolinium-enhanced MR angiography versus color-guided duplex US - A meta-analysis

被引:131
作者
Visser, K
Hunink, MGM
机构
[1] Erasmus MC, Dept Epidemiol & Biostat, NL-3015 GE Rotterdam, Netherlands
[2] Erasmus MC, Dept Radiol, NL-3015 GE Rotterdam, Netherlands
[3] Harvard Univ, Sch Publ Hlth, Dept Hlth Policy & Management, Boston, MA 02115 USA
关键词
arteries; extremities; stenosis or obstruction; MR; US; magnetic resonance (MR); comparative studies; ultrasound; (US);
D O I
10.1148/radiology.216.1.r00jl0367
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To summarize and compare the published data on gadolinium-enhanced magnetic resonance (MR) angiography and color-guided duplex ultrasonography (US) for the work-up for peripheral arterial disease. MATERIALS AND METHODS: Studies published between January 1984 and November 1998 were included if (a) gadolinium-enhanced MR angiography and/or color-guided duplex US were performed for evaluation of arterial stenoses and occlusions in the work-up for peripheral arterial disease of the lower extremities, (b) conventional angiography was the reference standard, and (c) absolute numbers of true-positive, false-negative, true-negative, and false-positive results were available or derivable. RESULTS: With a random effects model, pooled sensitivity for MR angiography (97.5% [95% CI: 95.7%, 99.3%]) was higher than that for duplex US (87.6% [95% CI: 84.4%, 90.8%]). Pooled specificities were similar: 96.2% (95% CI: 94.4%, 97.9%) for MR angiography and 94.7% (95% CI: 93.2%, 96.2%) for duplex US. Summary receiver operating characteristic analysis demonstrated better discriminatory power for MR angiography than for duplex US. Regression coefficients for MR angiography versus US were 1.67 (95% CI: -0.23, 3.56) with adjustment for covariates, 2.11 (95% CI: 0.12, 4.09) without such adjustment, and 1.73 (95% CI: 0.44, 3.02) with a random effects model. CONCLUSION: Gadolinium-enhanced MR angiography has better discriminatory power than does color-guided duplex US and is a highly sensitive and specific method, as compared with conventional angiography, for the work-up for peripheral arterial disease.
引用
收藏
页码:67 / 77
页数:11
相关论文
共 54 条
  • [41] PERIPHERAL ARTERIAL OCCLUSIVE DISEASE - PROSPECTIVE COMPARISON OF MR ANGIOGRAPHY AND COLOR DUPLEX US WITH CONVENTIONAL ANGIOGRAPHY
    MULLIGAN, SA
    MATSUDA, T
    LANZER, P
    GROSS, GM
    ROUTH, WD
    KELLER, FS
    KOSLIN, DB
    BERLAND, LL
    FIELDS, MD
    DOYLE, M
    CRANNEY, GB
    LEE, JY
    POHOST, GM
    [J]. RADIOLOGY, 1991, 178 (03) : 695 - 700
  • [42] MAGNETIC-RESONANCE-IMAGING OF ANGIOGRAPHICALLY OCCULT RUNOFF VESSELS IN PERIPHERAL ARTERIAL OCCLUSIVE DISEASE
    OWEN, RS
    CARPENTER, JP
    BAUM, RA
    PERLOFF, LJ
    COPE, C
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (24) : 1577 - 1581
  • [43] Pinto F, 1996, J ULTRAS MED, V15, P697
  • [44] DETERMINATION OF THE EXTENT OF LOWER-EXTREMITY PERIPHERAL ARTERIAL-DISEASE WITH COLOR-ASSISTED DUPLEX SONOGRAPHY - COMPARISON WITH ANGIOGRAPHY
    POLAK, JF
    KARMEL, MI
    MANNICK, JA
    OLEARY, DH
    DONALDSON, MC
    WHITTEMORE, AD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) : 1085 - 1089
  • [45] Iliac artery stenosis measurements: Comparison of two-dimensional time-of-flight and three-dimensional dynamic gadolinium-enhanced MR angiography
    Poon, E
    Yucel, EK
    PaganMarin, H
    Kayne, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) : 1139 - 1144
  • [46] Evaluation of the iliac arteries: Comparison of two-dimensional time of flight magnetic resonance angiography with cardiac compensated fast gradient recalled echo and contrast-enhanced three-dimensional time of flight magnetic resonance angiography
    Quinn, SF
    Sheley, RC
    Szumowski, J
    Shimakawa, A
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01): : 197 - 203
  • [47] Aortic and lower-extremity arterial disease: Evaluation with MR angiography versus conventional angiography
    Quinn, SF
    Sheley, RC
    Semonsen, KG
    Leonardo, VJ
    Kojima, K
    Szumowski, J
    [J]. RADIOLOGY, 1998, 206 (03) : 693 - 701
  • [48] Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography
    Rofsky, NM
    Johnson, G
    Adelman, MA
    Rosen, RJ
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1997, 205 (01) : 163 - 169
  • [49] A prospective comparison of lower limb colour-coded duplex scanning with arteriography
    Sensier, Y
    Hartshorne, T
    Thrush, A
    Nydahl, S
    Bolia, A
    London, NJM
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 11 (02) : 170 - 175
  • [50] The effect of adjacent segment disease on the accuracy of colour Duplex scanning for the diagnosis of lower limb arterial disease
    Sensier, Y
    Hartshorne, T
    Thrush, A
    Handford, H
    Nydahl, S
    London, NJM
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (02) : 238 - 242