Flow injection on-line solid phase extraction coupled with inductively coupled plasma mass spectrometry for determination of (ultra)trace rare earth elements in environmental materials using maleic acid grafted polytetrafluoroethylene fibers as sorbent

被引:47
作者
Wang, Zhao-Hui [1 ]
Yan, Xiu-Ping [1 ]
Wang, Zhi-Peng [1 ]
Zhang, Zheng-Pu [1 ]
Liu, Li-Wen [1 ]
机构
[1] Nankai Univ, Coll Chem, Res Ctr Analyt Sci, Minist Educ,Key Lab Funct Polymer Mat, Tianjin 300071, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1016/j.jasms.2006.05.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new sorbent, maleic acid grafted polytetrafluoroethylene fiber (MA-PTFE), was prepared and evaluated for on-line solid-phase extraction coupled with inductively coupled plasma mass spectrometry (ICP-MS) for fast, selective, and sensitive determination of (ultra)trace rare earth elements (REEs) in environmental samples. The REEs in aqueous samples at pH = 3.0 were selectively extracted onto a microcolumn packed with the MA-PTFE fiber, and the adsorbed REEs were subsequently eluted on-line with 0.9 mol 1(-1) HNO3 for ICP-MS determination. The new sorbent extraction system allows effective preconcentration and separation of the REEs from the major matrix constituents of alkali and alkali earth elements, particularly their separation from barium that produces considerable isobaric interferences of (BaOH+)-Ba-134-O-16-H-1, (BaO+)-Ba-135-O-16,(BaOH+)-Ba-136-O-16-H-1, and (BaO+)-Ba-137-O-16 on Eu-151(+) and Eu-153(+). With the use of a sample loading flow rate of 7.4 ml min(-1) for 120 s preconcentration, enhancement factors of 69-97 and detection limits (3s) of 1-20 pg 1(-1) were achieved at a sample throughput of 22 samples h(-1). The precision (RSD) for 16 replicate determinations of 50 ng 1(-1) of REEs was 0.5-1.1%. The developed method was successfully applied to the determination of (ultra)trace REEs in sediment, soil, and seawater samples. (J Am Soc Mass Spectrom 2006,17, 1258-1264) (c) 2006 American Society for Mass Spectrometry.
引用
收藏
页码:1258 / 1264
页数:7
相关论文
共 29 条
[1]   Determination of the rare earth elements in aqueous samples at sub-ppt levels by inductively coupled plasma mass spectrometry and flow injection ICPMS [J].
Aggarwal, JK ;
Shabani, MB ;
Palmer, MR ;
Ragnarsdottir, KV .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4418-4423
[2]  
ALBARADE F, 2004, GEOCHEMISTRY INTRO, P248
[3]   NATURAL ANALOG STUDIES - GEOLOGY AND MINERALOGY OF MORRO DO FERRO, BRAZIL [J].
BARRETTO, PMC ;
FUJIMORI, K .
CHEMICAL GEOLOGY, 1986, 55 (3-4) :297-312
[4]   Inductively coupled plasma mass spectrometry [J].
Beauchemin, D .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2873-2893
[5]  
Chen W, 1998, J POLYM SCI POL CHEM, V36, P357, DOI 10.1002/(SICI)1099-0518(19980130)36:2<357::AID-POLA18>3.0.CO
[6]  
2-N
[7]   Sorption behaviour of lanthanum(III), neodymium(III), terbium(III), thorium(IV) and uranium(VI) on Amberlite XAD-4 resin functionalized with bicine ligands [J].
Dev, K ;
Pathak, R ;
Rao, GN .
TALANTA, 1999, 48 (03) :579-584
[8]   PRECONCENTRATION AND PURIFICATION OF RARE-EARTH ELEMENTS IN NATURAL-WATERS USING SILICA-IMMOBILIZED 8-HYDROXYQUINOLINE AND A SUPPORTED ORGANOPHOSPHORUS EXTRACTANT [J].
ESSER, BK ;
VOLPE, A ;
KENNEALLY, JM ;
SMITH, DK .
ANALYTICAL CHEMISTRY, 1994, 66 (10) :1736-1742
[9]  
FANG ZL, 1993, FLOW INJECTION SEPAR, P98
[10]   Toward the next generation of atomic mass spectrometers - Plenary lecture [J].
Hieftje, GM ;
Myers, DP ;
Li, GQ ;
Mahoney, PP ;
Burgoyne, TW ;
Ray, SJ ;
Guzowski, JP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :287-292