Simultaneous determination of the HIV protease inhibitors indinavir, amprenavir, saquinavir, ritonavir, nelfinavir and the non-nucleoside reverse transcriptase inhibitor efavirenz by high-performance liquid chromatography after solid-phase extraction

被引:115
作者
Marzolini, C
Telenti, A
Buclin, T
Biollaz, J
Decosterd, LA [1 ]
机构
[1] CHU Vaudois, Dept Med, Div Clin Pharmacol, CH-1011 Lausanne, Switzerland
[2] CHU Vaudois, Duv Malad Infect, Lausanne, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2000年 / 740卷 / 01期
关键词
protease inhibitors; indinavir; amprenavir; saquinavir; ritonavir; nelfinavir; efavirenz;
D O I
10.1016/S0378-4347(99)00573-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As part of an on-going study on the suitability of a formal therapeutic drug monitoring (TDM) of antiviral drugs for improving the management of HIV infection, a high-performance liquid chromatography method has been developed to quantify simultaneously in plasma five HIV protease inhibitors (PIs) (i.e., indinavir, amprenavir, saquinavir, ritonavir, nelfinavir) and the novel non-nucleoside reverse transcriptase inhibitor efavirenz. After viral inactivation by heat (60 degrees C for 60 min), plasma (600 mu l), with clozapine added as internal standard, is diluted 1:1 with phosphate buffer, pH 7 and subjected to a solid-phase extraction on a C-18 cartridge. Matrix components are eliminated with 2x500 mu l of a solution of 0.1% H3PO4 neutralised with NaOH to pH 7. PIs and efavirenz are eluted with 3X500 mu l MeOH. The resulting eluate is evaporated under nitrogen at room temperature and is reconstituted in 100 mu l 50% MeOH. A 40-mu l volume is subjected to HPLC analysis onto a Nucleosil 100, 5 mu m C-18 AB column, using a gradient elution of MeCN and phosphate buffer adjusted to pH 5.15 and containing 0.02% sodium heptanesulfonate: 15:85 at 0 min-->30:70 at 2 min-->32:68 at 8 min-->42:58 at 18 min-->46:54 at 34 min, followed by column cleaning with MeCN-buffer, pH 5.15 (90.10), onto which 0.3% AcOH is added. Clozapine, indinavir, amprenavir, saquinavir, ritonavir, efavirenz and nelfinavir are detected by UV at 201 nm at a retention time of 8.2,, 13.0, 16.3, 21.5, 26.5, 28.7 and 31.9 min, respectively. The total run time for a single analysis is 47 min, including the washing-out and reequilibration steps. The calibration curves are linear over the range 100-10 000 ng/ml. The absolute recovery of PIs/efavirenz is always higher than 88%. The method is precise with mean inter-day relative standard deviations within 2.5-9.8% and accurate (range of inter-day deviations -4.6 to +4.3%). The in vitro stability of plasma spiked with PIs/efavirenz at 750, 3000 and 9000 ng/ml has been studied at room temperature, -20 degrees C and +60 degrees C. The method has been validated and is currently applied to the monitoring of PIs and efavirenz in HIV patients. This HPLC assay may help clinicians confronted to questionable compliance, side effects or treatment failure in elucidating whether patients are exposed to adequate circulating drug levels. The availability of such an assay represents an essential step in elucidating the utility of a formal TDM for the optimal follow-up of HN patients. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:43 / 58
页数:16
相关论文
共 33 条
  • [1] ACOSTA E, 1999, MEDSCAPE HIV AIDS, V5
  • [2] Efavirenz
    Adkins, JC
    Noble, S
    [J]. DRUGS, 1998, 56 (06) : 1055 - 1064
  • [3] Determination of indinavir, an HIV-protease inhibitor, in human plasma by reversed-phase high-performance liquid chromatography
    Burger, DM
    de Graaff, M
    Wuis, EW
    Koopmans, PP
    Hekster, YA
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 703 (1-2): : 235 - 241
  • [4] DELFRAISSY JF, 1999, PRISE CHARGE THERAPE, P112
  • [5] Simultaneous determination of ritonavir and saquinavir, two human immunodeficiency virus protease inhibitors, in human serum by high-performance liquid chromatography
    Frappier, S
    Breilh, D
    Diarte, E
    Ba, B
    Ducint, D
    Pellegrin, JL
    Saux, MC
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 714 (02): : 384 - 389
  • [6] Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection
    Fu, I
    Woolf, EJ
    Matuszewski, BK
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (03) : 347 - 357
  • [7] GALLICANO K, 1999, THER DRUG MONIT, V21, P453
  • [8] Gazzard BG, 1999, INT J CLIN PRACT, V53, P60
  • [9] SIMULTANEOUS QUANTIFICATION OF ZIDOVUDINE AND ITS GLUCURONIDE IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GOOD, SS
    REYNOLDS, DJ
    DEMIRANDA, P
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 431 (01): : 123 - 133
  • [10] Determination of saquinavir in human plasma by high-performance liquid chromatography
    Ha, HR
    Follath, F
    Bloemhard, Y
    Krahenbuhl, S
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 694 (02): : 427 - 433