Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system

被引:247
作者
Lagally, ET
Simpson, PC
Mathies, RA
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, UC Berkeley UC San Francisco Joint Bioengn Grad G, Berkeley, CA 94720 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2000年 / 63卷 / 03期
关键词
monolithic integration; microfluidic PCR amplification; capillary electrophoresis;
D O I
10.1016/S0925-4005(00)00350-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A monolithic integrated DNA analysis system comprised of microfluidic valves and vents, PCR amplification chambers, and capillary electrophoretic separation channels has been microfabricated in a glass sandwich structure. Valves and hydrophobic vents provide controlled and sensorless sample loading into 280 nl PCR chambers; the low volume reactor and the use of thin film heaters permit thermal cycle times as fast as 30 s. The amplified product is labeled with an intercalating fluorescent dye and directly injected into a microfabricated capillary electrophoresis channel. Analyses with this device have produced and detected PCR products from reactions with as few as 20 starting DNA template copies/mu l, (five to six copies/chamber), The extrapolated limit of detection based on data using 20 cycles is two copies/chamber. The optimization of heater placement, thermal anisotropy measurements, and the optimization of thermal profiles are also discussed. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:138 / 146
页数:9
相关论文
共 24 条
[1]  
Anderson RC, 1997, TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P477, DOI 10.1109/SENSOR.1997.613690
[2]   Transient liquid crystal thermometry of microfabricated PCR vessel arrays [J].
Chaudhari, AM ;
Woudenberg, TM ;
Albin, M ;
Goodson, KE .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1998, 7 (04) :345-355
[3]   Chip PCR .2. Investigation of different PCR amplification systems in microfabricated silicon-glass chips [J].
Cheng, J ;
Shoffner, MA ;
Hvichia, GE ;
Kricka, LJ ;
Wilding, P .
NUCLEIC ACIDS RESEARCH, 1996, 24 (02) :380-385
[4]   Multiplex dsDNA fragment sizing using dimeric intercalation dyes and capillary array electrophoresis: Ionic effects on the stability and electrophoretic mobility of DNA-dye complexes [J].
Clark, SM ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1355-1363
[5]   Silicon microchambers for DNA amplification [J].
Daniel, JH ;
Iqbal, S ;
Millington, RB ;
Moore, DF ;
Lowe, CR ;
Leslie, DL ;
Lee, MA ;
Pearce, MJ .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 71 (1-2) :81-88
[6]  
ERLICH HA, 1989, PCR TECHNOLOGY, P1
[7]   NORMALLY CLOSED MICROVALVE AND MICROPUMP FABRICATED ON A SILICON-WAFER [J].
ESASHI, M ;
SHOJI, S ;
NAKANO, A .
SENSORS AND ACTUATORS, 1989, 20 (1-2) :163-169
[8]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[9]   Chemical amplification: Continuous-flow PCR on a chip [J].
Kopp, MU ;
de Mello, AJ ;
Manz, A .
SCIENCE, 1998, 280 (5366) :1046-1048
[10]   SPECIFIC ENZYMATIC AMPLIFICATION OF DNA INVITRO - THE POLYMERASE CHAIN-REACTION [J].
MULLIS, K ;
FALOONA, F ;
SCHARF, S ;
SAIKI, R ;
HORN, G ;
ERLICH, H .
COLD SPRING HARBOR SYMPOSIA ON QUANTITATIVE BIOLOGY, 1986, 51 :263-273