High-voltage capacitively coupled contactless conductivity detection for microchip capillary electrophoresis

被引:127
作者
Tanyanyiwa, J [1 ]
Hauser, PC [1 ]
机构
[1] Univ Basel, Dept Chem, CH-4004 Basel, Switzerland
关键词
D O I
10.1021/ac020489+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Contactless conductivity detection was carried out on a planar electrophoresis device by capacitive coupling using an ac excitation voltage of 500 Vp-p and a frequency of 100 kHz. It was possible to carry out detection in this way through a cover plate of 1 mm thickness. Better sensitivity is obtained, however, by placing the electrodes into troughs that allow tighter coupling to the separation channel. The 3 x S/N detection limits are 0.49, 0.41, and 0.35 muM for the small inorganic ions K+, Na+, and Mg2+. The detection of heavy metals is demonstrated with the example of Mn2+, Zn2+, and Cr3+ with detection limits of 2.1, 2.8, and 6.8 muM, respectively. The universal nature of the method is further illustrated by the detection of citric and lactic acids, which are of interest in food and beverage analysis, and detection of three antinflammatory nonsteroid drugs, 4-acetamidophenol, ibuprofen, and salicylic acid, as examples of species of pharmaceutical interest.
引用
收藏
页码:6378 / 6382
页数:5
相关论文
共 55 条
[41]   Powder-blasting technology as an alternative tool for microfabrication of capillary electrophoresis chips with integrated conductivity sensors [J].
Schlautmann, S ;
Wensink, H ;
Schasfoort, R ;
Elwenspoek, M ;
van den Berg, A .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2001, 11 (04) :386-389
[42]  
Schlegel D, 1996, FRESEN J ANAL CHEM, V354, P535
[43]   Recent developments in detection methods for microfabricated analytical devices [J].
Schwarz, MA ;
Hauser, PC .
LAB ON A CHIP, 2001, 1 (01) :1-6
[44]   Improved capacitively coupled conductivity detector for capillary electrophoresis [J].
Tanyanyiwa, J ;
Galliker, B ;
Schwarz, MA ;
Hauser, PC .
ANALYST, 2002, 127 (02) :214-218
[45]  
TANYANYIWA J, IN PRESS ELECTROPHOR
[46]  
Tuma P, 2001, ELECTROANAL, V13, P989, DOI 10.1002/1521-4109(200108)13:12<989::AID-ELAN989>3.0.CO
[47]  
2-C
[48]   Simultaneous separation of inorganic anions and cations using capillary electrophoresis with a movable contactless conductivity detector [J].
Unterholzner, V ;
Macka, M ;
Haddad, PR ;
Zemann, A .
ANALYST, 2002, 127 (06) :715-718
[49]   Determination of anions in rainwater by capillary electrophoresis with conductivity detection [J].
Valsecchi, S ;
Tartari, G ;
Polesello, S .
JOURNAL OF CHROMATOGRAPHY A, 1997, 760 (02) :326-332
[50]   A chip-based capillary electrophoresis-contactless conductivity microsystem for fast measurements of low-explosive ionic components [J].
Wang, J ;
Pumera, M ;
Collins, G ;
Opekar, F ;
Jelinek, I .
ANALYST, 2002, 127 (06) :719-723