摘要
PURPOSE. To assess the strength of the association between retinal nerve fiber layer (RNFL) thickness and optic disc topography measured with confocal retinal tomography (HRT II; Heidelberg Engineering, Dossenheim, Germany), optical coherence tomography (StratusOCT; Carl Zeiss Meditec, Inc., Dublin, CA), and scanning laser polarimetry (GDx with variable corneal compensator, VCC; Carl Zeiss Meditec, Inc.), and visual field (VF) sensitivity and to determine whether this association is better expressed as a linear or nonlinear function. METHODS. One hundred twenty-seven patients with glaucoma or suspected glaucoma and 127 healthy eyes from enrollees in the Diagnostic Innovations in Glaucoma Study (DIGS) were tested on HRT II, StratusOCT, GDx VCC, and standard automated perimetry (SAP, with the Swedish Interactive Thresholding Algorithm [SITA]) within 3 months of each other. Linear and logarithmic associations between RNFL thickness (HRT II, StratusOCT, and GDx VCC) and neuroretinal rim area (HRT II) and SAP sensitivity expressed in decibels were determined globally and for six RNFL/optic disc regions (inferonasal, inferotemporal, temporal, superotemporal, superonasal, and nasal) and six corresponding VF regions (superior, superonasal, nasal, inferonasal, inferior, and temporal). RESULTS. The associations (R-2) between global and regional RNFL/optic disc measurements and VF sensitivity ranged from < 0.01 (temporal RNFL, nasal VF, and nasal RNFL, temporal VF; linear and logarithmic associations) to 0.26 (inferotemporal RNFL, superonasal VF; logarithmic association) for HRT II; from 0.02 (temporal RNFL, nasal VF; linear association) to 0.38 (inferotemporal RNFL, superonasal VF; logarithmic association) for OCT; and from 0.03 (temporal RNFL, nasal VF; linear association) to 0.21 (inferotemporal RNFL, superonasal VF; logarithmic association) for GDx. Structure-function relationships generally were strongest between the inferotemporal RNFL-optic disc sector and the superonasal visual field and were significantly stronger for StratusOCT RNFL thickness than for other instruments in this region. Global associations (linear and logarithmic) were significantly stronger using OCT compared with HRT. In most cases, logarithmic fits were not significantly better than linear fits when visual sensitivity was expressed in log units (i.e., decibels). CONCLUSIONS. These results suggest that structure-function associations are strongest with StratusOCT measurements and are similar between HRT II and GDx VCC and these associations are generally no better expressed logarithmically than linearly when healthy, suspect, and glaucomatous eyes are considered.
引用
收藏
页码:2889 / 2895
页数:7
相关论文
共 28 条
[21]   Relationships between standard automated perimetry, HRT confocal scanning laser ophthalmoscopy, and GDx VCC scanning laser polarimetry [J].
Reus, NJ ;
Lemij, HG .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (11) :4182-4188
[22]   The relationship between standard automated perimetry and GDx VCC measurements [J].
Reus, NJ ;
Lemij, HG .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (03) :840-845
[23]   Short-wavelength automated perimetry results are correlated with optical coherence tomography retinal nerve fiber layer thickness measurements in glaucomatous eyes [J].
Sánchez-Galeana, CA ;
Bowd, C ;
Zangwill, LM ;
Sample, PA ;
Weinreb, RN .
OPHTHALMOLOGY, 2004, 111 (10) :1866-1872
[24]   Relationship between visual field sensitivity and retinal nerve fiber layer thickness as measured by scanning laser polarimetry [J].
Schlottmann, PG ;
De Cilla, S ;
Greenfield, DS ;
Caprioli, J ;
Garway-Heath, DF .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (06) :1823-1829
[25]   QUANTIFICATION OF NERVE-FIBER LAYER THICKNESS IN NORMAL AND GLAUCOMATOUS EYES USING OPTICAL COHERENCE TOMOGRAPHY - A PILOT-STUDY [J].
SCHUMAN, JS ;
HEE, MR ;
PULIAFITO, CA ;
WONG, C ;
PEDUTKLOIZMAN, T ;
LIN, CP ;
HERTZMARK, E ;
IZATT, JA ;
SWANSON, EA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (05) :586-596
[26]   Mapping structural damage of the optic disk to visual field defect in glaucoma [J].
Yamagishi, N ;
Anton, A ;
Sample, PA ;
Zangwill, L ;
Lopez, A ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (05) :667-676
[27]  
Zangwill LM, 2004, ESSENT OPHTHALMOL, P63
[28]   A comparison of optical coherence tomography and retinal nerve fiber layer photography for detection of nerve fiber layer damage in glaucoma [J].
Zangwill, LM ;
Williams, J ;
Berry, CC ;
Knauer, S ;
Weinreb, RN .
OPHTHALMOLOGY, 2000, 107 (07) :1309-1315