Radiation from "extra" images acquired with abdominal and/or pelvic CT: Effect of automatic tube current modulation

被引:47
作者
Kalra, MK
Maher, MM
Toth, TL
Kamath, RS
Halpern, EF
Saini, S
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Div Abdominal Imaging & Intervent, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] GE Med Syst, Waukesha, WI USA
关键词
abdomen; CT; computed tomography (CT); radiation exposure; thin section; pelvis; special reports;
D O I
10.1148/radiol.2322031151
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To retrospectively determine the number and usefulness of images acquired beyond the intended anatomic area of interest with abdominal and/or pelvic computed tomography (CT) and to assess the effect of automatic tube current modulation (ATCM) on associated radiation. MATERIALS AND METHODS: Superior and inferior levels at routine abdominal and/or pelvic CT were defined as the dome of the diaphragm and the inferior margin of the pubic symphysis, respectively. Records of 106 consecutive examinations (male-to-female ratio, 45:61; age range, 21-86 years) performed from June I to June 30, 2003, were reviewed to determine the number of "extra" images. Sixty-two abdominal and/or pelvic CT examinations performed concurrently with chest or thigh CT or for trauma were not included in the 106. Abdominal and/or pelvic CT was performed with either ATCM (n = 44) or manual selection of tube current (n = 62). CT parameters recorded for each extra image included tube current, peak kilovoltage, and gantry rotation time. Mean and median tube current-time products were calculated for extra images. Extra images were analyzed for pathologic findings. Statistical analysis was performed with the Student t test. RESULTS: Extra images were acquired above the dome of the diaphragm in 103 (97%) of 106 examinations and below the pubic symphysis in 100 (94%) of 106. A total of 1,280 extra images were acquired in 106 examinations (mean, 12 images per examination). Nineteen additional findings were observed on extra images. With ATCM, mean tube current-time product was 74.5 and 120.6 mAs for extra images acquired above the diaphragm and below the pubic symphysis, respectively; with manual selection, mean tube current-time products were 167.5 and 168.3 mAs (P < .05). CONCLUSION: Most extra images acquired at abdominal and/or pelvic CT contributed no additional information. With ATCM, the radiation dose was reduced by a mean of 56% (median, 72%) for extra images above the diaphragm and 29% (median, 36%) for images below the pubic symphysis, compared with dose levels with manual selection. (C) RSNA, 2004.
引用
收藏
页码:409 / 414
页数:6
相关论文
共 12 条
[1]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[2]  
*GE MED SYST, 2003, LIGHTSP 4 X TECHN RE
[3]   Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose) [J].
Greess, H ;
Nömayr, A ;
Wolf, H ;
Baum, U ;
Lell, M ;
Böwing, B ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1571-1576
[4]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[5]   Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers [J].
Kalender, WA ;
Wolf, H ;
Suess, C ;
Gies, M ;
Greess, H ;
Bautz, WA .
EUROPEAN RADIOLOGY, 1999, 9 (02) :323-328
[6]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[7]   Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study [J].
Kalra, MK ;
Wittram, C ;
Maher, MM ;
Sharma, A ;
Avinash, GB ;
Karau, K ;
Toth, TL ;
Halpern, E ;
Saini, S ;
Shepard, JA .
RADIOLOGY, 2003, 228 (01) :257-264
[8]   Low-dose CT of the abdomen: Evaluation of image improvement with use of noise reduction filters - Pilot study [J].
Kalra, MK ;
Maher, MM ;
Sahani, DV ;
Blake, MA ;
Hahn, PF ;
Avinash, GB ;
Toth, TL ;
Halpern, E ;
Saini, S .
RADIOLOGY, 2003, 228 (01) :251-256
[9]   Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality [J].
Kalra, MK ;
Prasad, S ;
Saini, S ;
Blake, MA ;
Varghese, J ;
Halpern, EF ;
Thrall, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) :1101-1106
[10]   Radiation doses in computed tomography - The increasing doses of radiation need to be controlled [J].
Rehani, MM ;
Berry, M .
BRITISH MEDICAL JOURNAL, 2000, 320 (7235) :593-594