Scaling-up of a lactose wet granulation process in Mi-Pro high shear mixers

被引:42
作者
Ameye, D
Keleb, E
Vervaet, C
Remon, JP
Adams, E
Massart, DL
机构
[1] State Univ Ghent, Fac Pharmaceut Sci, Pharmaceut Technol Lab, B-9000 Ghent, Belgium
[2] Free Univ Brussels, Inst Pharmaceut, B-1090 Brussels, Belgium
关键词
upscaling; lab scale; pilot scale; wet granulation; high shear mixer;
D O I
10.1016/S0928-0987(02)00218-X
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The high shear wet granulation upscaling possibilities of a Pro-C-epT Mi-Pro 250 ml with a batch size of 40 g were investigated by down-scaling an alpha-lactose monohydrate wet granulation process from a Collette Gral 10 (8 1 batch size) to a Pro-C-epT Mi-Pro with different bowl volumes of 5 1, and 1900, 900 and 250 ml. The wet granulation process was optimised in the Gral 10, next an octagonal design was build around the central point. Two process parameters, the impeller tip speed and the water content, were varied at three levels, which resulted in a two-factor three-level experimental design. alpha-Lactose monohydrate 200 M was granulated using a polyvinylpyrollidone K 30 (2.5% on dry material) binder solution. The granules were dried at 25 degreesC for 24 h, sieved and characterised. The granules were compressed to tablets. In all mixer volumes the used impeller tip speed range did not influence the granule or tablet properties. In all bowl volumes the influence of water concentration on actual yield, particle size distribution and granule friability was similar. All batch sizes resulted in tablets of similar quality. For the selected formulation the tab scale Mi-Pro high shear mixers with different bowl volumes could be used to determine the optimal process parameters and to scale up to the Collette Gral 10 pilot scale. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:247 / 251
页数:5
相关论文
共 8 条
[1]   Applicability of a scale-up methodology for wet granulation processes in Collette Gral high shear mixer-granulators [J].
Faure, A ;
Grimsey, IM ;
Rowe, RC ;
York, P ;
Cliff, MJ .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 1999, 8 (02) :85-93
[2]   DETERMINATION OF TABLET STRENGTH BY DIAMETRAL-COMPRESSION TEST [J].
FELL, JT ;
NEWTON, JM .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1970, 59 (05) :688-&
[3]  
Franke G, 1999, PHARM IND, V61, P861
[4]  
Holm P., 1997, HDB PHARM GRANULATIO, V81, P151
[5]   STUDIES ON UPSCALING PARAMETERS OF THE GRAL HIGH SHEAR GRANULATION PROCESS [J].
HORSTHUIS, GJB ;
VANLAARHOVEN, JAH ;
VANROOIJ, RCBM ;
VROMANS, H .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1993, 92 (1-3) :143-150
[6]  
Leuenberger H, 1990, STP PHARM, V6, P303
[7]   A NEW ATTEMPT TO SOLVE THE SCALE-UP PROBLEM FOR GRANULATION USING RESPONSE-SURFACE METHODOLOGY [J].
OGAWA, S ;
KAMIJIMA, T ;
MIYAMOTO, Y ;
MIYAJIMA, M ;
SATO, H ;
TAKAYAMA, K ;
NAGAI, T .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (03) :439-443
[8]   SCALING-UP OF WET GRANULATION - A STATISTICAL METHODOLOGY [J].
WEHRLE, P ;
NOBELIS, P ;
CUINE, A ;
STAMM, A .