The unicompartmental knee - Design and technical considerations in minimizing wear

被引:61
作者
Argenson, Jean-Noel A. [1 ]
Parratte, Sebastien [1 ]
机构
[1] Univ Aix Marseille, Hop St Marguerite, Serv Chirurg Orthoped, F-13009 Marseille, France
关键词
D O I
10.1097/01.blo.0000229358.19867.60
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Unicompartmental knee arthroplasty is an alternative to total knee arthroplasty for patients with unicompartmental tibiofemoral noninflammatory disease. Careful patient selection and newer instrumentation has reduced the progression of arthrosis in the other compartment and tibial loosening, leaving polyethylene wear as the predominant failure mechanism in more contemporary designs. Increased wear increases the debris volume at the bone-implant interface, and wear particles will generate osteolysis leading to component loosening and unreplaced compartment degeneration. The design-related factors that minimize wear include a polyethylene thickness of greater than 6 mm, a limited shelf age, and a design allowing large areas of contact mediolaterally and anteroposteriorly. Congruous mobile-bearing implants could play a substantial role in reducing wear if they are not associated with dislocation and nonreproducible surgical techniques. Important technical factors include accurate instrumentation avoiding component-to-component malposition and edge loading, allowing slight under-correction of the preoperative deformity. The patient-related factors include a weight limit, a functional anterior cruciate ligament, and a correctable frontal deformity. Continued research including that related to cross-linking and sterilization methods is mandatory to improve polyethylene strength. A better understanding of kinematics and contact forces may provide long-term survival and patient satisfaction after unicompartmental arthroplasty.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 47 条
[1]   POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[2]   Modern unicompartmental knee arthroplasty with cement - A three to ten-year follow-up study [J].
Argenson, JNA ;
Chevrol-Benkeddache, Y ;
Aubaniac, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (12) :2235-2239
[3]   In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty [J].
Argenson, JNA ;
Komistek, RD ;
Aubaniac, JM ;
Dennis, DA ;
Northcut, EJ ;
Anderson, DT ;
Agostini, S .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1049-1054
[4]   Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis [J].
Ashraf, T ;
Newman, JH ;
Desai, VV ;
Beard, D ;
Nevelos, JE .
KNEE, 2004, 11 (03) :177-181
[5]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[6]   THE EFFECT OF CONFORMITY AND PLASTIC THICKNESS ON CONTACT STRESSES IN METAL-BACKED PLASTIC IMPLANTS [J].
BARTEL, DL ;
BURSTEIN, AH ;
TODA, MD ;
EDWARDS, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (03) :193-199
[7]  
BARTLEY RE, 1994, CLIN ORTHOP RELAT R, V299, P18
[8]  
BERGER RA, 1999, CLIN ORTHOP RELAT R, V367, P50
[9]   POLYETHYLENE WEAR IN UNICONDYLAR KNEE PROSTHESES - 106 RETRIEVED MARMOR, PCA, AND ST-GEORG TIBIAL COMPONENTS COMPARED [J].
BLUNN, GW ;
JOSHI, AB ;
LILLEY, PA ;
ENGELBRECHT, E ;
RYD, L ;
LIDGREN, L ;
HARDINGE, K ;
NIEDER, E ;
WALKER, PS .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (03) :247-255
[10]   Wear in retrieved condylar knee arthroplasties - A comparison of wear in different designs of 280 retrieved condylar knee prostheses [J].
Blunn, GW ;
Joshi, AB ;
Minns, RJ ;
Lidgren, L ;
Lilley, P ;
Ryd, L ;
Engelbrecht, E ;
Walker, PS .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :281-290