An integrated flow-cell for full sample stream control

被引:20
作者
Hairer, G. [1 ]
Vellekoop, M. J. [1 ]
机构
[1] Vienna Univ Technol, Inst Sensor & Actuator Syst, A-1040 Vienna, Austria
关键词
Microfluidics; Three-dimensional hydrodynamic focusing; Numerical simulations; Confocal laser scanning microscope; Dye intensity analysis; POLYDIMETHYLSILOXANE PDMS MICROCHANNELS; MICROFLUIDIC DEVICE; COULTER-COUNTER; SHEATH FLOW; PARTICLES; GENERATION; MOLECULES; CYTOMETER; CHANNEL; SYSTEMS;
D O I
10.1007/s10404-009-0425-6
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this study, we present a novel three-dimensional hydrodynamic sheath flow chip that allows full control of a sample stream. The chip offers the possibility to steer each of the four side sheath flows individually. The design of the flow-cell exhibits high flexibility in creating different sample stream profiles (width and height) and allows navigation of the sample stream to every desired position inside the microchannel (vertical and horizontal). This can be used to bring the sample stream to a sensing area for analysis, or to an area of actuation (e.g. for cell sorting). In addition, we studied the creation of very small sample stream diameters. In microchannels (typically 25 x 40 mu mA(2)), we created sample stream diameters that were five to ten times smaller than the channel dimensions, and the smallest measured sample stream width was 1.5 mu m. Typical flow rates are 0.5 mu l/min for the sample flow and around 100 mu l/min for the cumulated sheath flows. The planar microfabricated chip, consisting of a silicon-glass sandwich with an intermediate SU-8 layer, is much smaller (6 x 9 mmA(2)) than the previously presented sheath flow devices, which makes it also cost-effective. We present the chip design, fluidic simulation results and experiments, where the size, shape and position of the sample stream have been established by laser scanning confocal microscopy and dye intensity analysis.
引用
收藏
页码:647 / 658
页数:12
相关论文
共 39 条
[1]   Three-dimensional sheath flow sorting microsystem using thermosensitive hydrogel [J].
Arakawa, Takahiro ;
Shirasaki, Yoshitaka ;
Aoki, Tokihiko ;
Funatsu, Takashi ;
Shoji, Shuichi .
SENSORS AND ACTUATORS A-PHYSICAL, 2007, 135 (01) :99-105
[2]   Three-dimensional hydrodynamic focusing in two-layer polydimethylsiloxane (PDMS) microchannels [J].
Chang, Chih-Chang ;
Huang, Zhi-Xiong ;
Yang, Ruey-Jen .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (08) :1479-1486
[3]  
Chung S, 2003, MICROSYST TECHNOL, V9, P525, DOI 10.1007/S00542-003-0302-2
[4]   Control and detection of chemical reactions in microfluidic systems [J].
deMello, Andrew J. .
NATURE, 2006, 442 (7101) :394-402
[5]   Micro total analysis systems. Latest advancements and trends [J].
Dittrich, Petra S. ;
Tachikawa, Kaoru ;
Manz, Andreas .
ANALYTICAL CHEMISTRY, 2006, 78 (12) :3887-3907
[6]   Centrifugal generation and manipulation of droplet emulsions [J].
Haeberle, Stefan ;
Zengerle, Roland ;
Ducree, Jens .
MICROFLUIDICS AND NANOFLUIDICS, 2007, 3 (01) :65-75
[7]   Investigations of micrometer sample stream profiles in a three-dimensional hydrodynamic focusing device [J].
Hairer, G. ;
Paerr, G. S. ;
Svasek, P. ;
Jachimowicz, A. ;
Vellekoop, M. J. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (02) :518-524
[8]   High throughput particle analysis: Combining dielectrophoretic particle focussing with confocal optical detection [J].
Holmes, D ;
Morgan, H ;
Green, NG .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1621-1630
[9]   Synthesis of bio-functionalized copolymer particles bearing carboxyl groups via a microfluidic device [J].
Huang, Shih Hao ;
Khoo, Hwa Seng ;
ChangChien, Shang Yu ;
Tseng, Fan Gang .
MICROFLUIDICS AND NANOFLUIDICS, 2008, 5 (04) :459-468
[10]   Microfluidics for flow cytometric analysis of cells and particles [J].
Huh, D ;
Gu, W ;
Kamotani, Y ;
Grotberg, JB ;
Takayama, S .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (03) :R73-R98