Recent progress in open tubular liquid chromatography

被引:50
作者
Swart, R
Kraak, JC
Poppe, H
机构
关键词
D O I
10.1016/S0165-9936(97)00036-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article the state-of-the-art of Open Tubular Liquid Chromatography (OTLC) is discussed. In OTLC separations are performed in capillaries with an internal diameter of 5 to 10 mu m. Attention is given to the progress in the preparation of thick stationary phases in these capillaries and to detection. Various efficient separations on OTLC columns are shown.
引用
收藏
页码:332 / 342
页数:11
相关论文
共 46 条
[1]  
BARTLE KD, 1987, HRC-J HIGH RES CHROM, V10, P125
[2]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[3]   ELECTRICALLY DRIVEN OPEN-TUBULAR LIQUID-CHROMATOGRAPHY [J].
BRUIN, GJM ;
TOCK, PPH ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1990, 517 :557-572
[4]   PREPARATION OF OPEN-TUBULAR COLUMNS FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CREGO, AL ;
DIEZMASA, JC ;
DABRIO, MV .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1615-1621
[5]   NEW METHOD FOR THE PREPARATION OF SMALL DIAMETER COLUMNS WITH POLYMERIC STATIONARY PHASES FOR OPEN TUBULAR LIQUID-CHROMATOGRAPHY [J].
DLUZNESKI, PR ;
JORGENSON, JW .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (04) :332-336
[6]   FABRICATION OF COLUMNS FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY USING PHOTOPOLYMERIZATION OF ACRYLATES [J].
EGUCHI, S ;
KLOOSTERBOER, JG ;
ZEGERS, CPG ;
SCHOENMAKERS, PJ ;
TOCK, PPH ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (02) :301-312
[7]   SWOLLEN POLYSILOXANES AS STATIONARY PHASES IN REVERSED-PHASE OPEN-TUBULAR COLUMN LIQUID-CHROMATOGRAPHY [J].
FOLESTAD, S ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 394 (03) :455-464
[8]   PERFORMANCE AND PREPARATION OF IMMOBILIZED POLYSILOXANE STATIONARY PHASES IN 5-55 MU-M ID OPEN-TUBULAR FUSED-SILICA COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
FOLESTAD, S ;
JOSEFSSON, B ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 391 (02) :347-372
[9]   PACKING TECHNOLOGY, COLUMN BED STRUCTURE AND CHROMATOGRAPHIC PERFORMANCE OF 1-2-MU-M NON-POROUS SILICAS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GIESCHE, H ;
UNGER, KK ;
ESSER, U ;
ERAY, B ;
TRUDINGER, U ;
KINKEL, JN .
JOURNAL OF CHROMATOGRAPHY, 1989, 465 (01) :39-57
[10]   STUDY OF POLYORGANOSILOXANES (NATIVE AND SOLVENT SWOLLEN) FOR THE PREPARATION OF NARROW (5-15 MU-M ID) AND LONG (1-6 M) OPEN-TUBULAR COLUMNS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
GOHLIN, K ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (01) :41-56