Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging

被引:46
作者
Brown, PH [1 ]
Thomas, RD [1 ]
Silberberg, PJ [1 ]
Johnson, LM [1 ]
机构
[1] Oregon Hlth Sci Univ, Dept Diagnost Radiol L340, Doernbecher Childrens Hosp, Portland, OR 97201 USA
关键词
D O I
10.1007/s002470050728
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background. A new children's hospital provided the impetus to investigate radiation dose and image quality in a fluoroscope that was specially engineered for pediatric fluoroscopy. Radiation protection management recommends radiation exposures that are as low as reasonably achievable, while still maintaining diagnostic image quality. Objectives. To obtain comparative phantom imaging data on radiation exposure and image quality from a newly installed fluoroscope before and after optimization for pediatric imaging. Materials and methods. Images were acquired from various thickness phantoms, simulating differing patient sizes. The images were evaluated for visualization of high- and low-contrast objects and for radiation exposure. Effects due to use of the image intensifier anti-scatter grid were also investigated. Results. The optimization of the new fluoroscope for pediatric operation reduced radiation exposure by about 50% (compared to the originally installed fluoroscope), with very little loss of image quality. Pulsed fluoroscopy was able to lower radiation dose to less than 10% of continuous fluoroscopy, while still maintaining acceptable phantom image quality. Conclusion. Radiation exposure in pediatric fluoroscopy can be reduced to values well below the exposure settings that are typically found on unoptimized fluoroscopes. Pulsed fluoroscopy is considered a requisite for optimal pediatric fluoroscopy.
引用
收藏
页码:229 / 235
页数:7
相关论文
共 17 条
[1]   PERCEPTUAL COMPARISON OF PULSED AND CONTINUOUS FLUOROSCOPY [J].
AUFRICHTIG, R ;
XUE, P ;
THOMAS, CW ;
GILMORE, GC ;
WILSON, DL .
MEDICAL PHYSICS, 1994, 21 (02) :245-256
[2]  
BOER A, 1994, CIRCULATION, V89, P2710
[3]  
BROWN H, 2000, IN PRESSPEDIAT RADIO, V30
[4]   DOSE REDUCTION IN PEDIATRIC RADIOLOGY USING RARE-EARTH FILTRATION [J].
FLEAY, RF ;
FOX, RA ;
SPRAGUE, PL ;
ADAMS, JP .
PEDIATRIC RADIOLOGY, 1984, 14 (05) :332-334
[5]  
GAGNE RM, 1995, SYLLABUS CATEGORICAL, P49
[6]  
Hahn H., 1997, Medicamundi, V41, P12
[7]   Added copper filtration in digital paediatric double-contrast colon examinations: effects on radiation dose and image quality [J].
Hansson, B ;
Finnbogason, T ;
Schuwert, P ;
Persliden, J .
EUROPEAN RADIOLOGY, 1997, 7 (07) :1117-1122
[8]   Reduction of radiation dose in pediatric patients using pulsed fluoroscopy [J].
Hernandez, RJ ;
Goodsitt, MM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (05) :1247-1253
[9]   The secondary radiation grid its effect on fluoroscopic dose-area product during barium enema examinations [J].
Lloyd, P ;
Lowe, D ;
Harty, DS ;
Eyes, B .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (843) :303-306
[10]   REDUCTION OF PATIENT DOSES FROM BARIUM MEAL AND BARIUM ENEMA EXAMINATIONS THROUGH CHANGES IN EQUIPMENT FACTORS [J].
MARTIN, CJ ;
HUNTER, S .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (804) :1196-1205