An aptamer-based biosensor for sensitive thrombin detection

被引:88
作者
Yang, Hui [1 ]
Ji, Ji [1 ]
Liu, Yun [1 ]
Kong, Jilie [1 ]
Liu, Baohong [1 ]
机构
[1] Fudan Univ, Dept Chem, Inst Biomed Sci, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
Aptamer; Quantum dots; Thrombin; Electrochemistry; Sensor; ELECTROCHEMICAL DETECTION; REAGENTLESS; LABELS; DNA; APTASENSOR; SELECTION; PROTEINS; SENSOR; SWITCH;
D O I
10.1016/j.elecom.2008.10.024
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A sensitive aptamer-based sandwich-type sensor is presented to detect human thrombin using quantum dots as electrochemical label. CdSe quantum dots were labeled to the secondary aptamer, which were determined by the square wave stripping voltammetric analysis after dissolution with nitric acid. The aptasensor has a lower detection limit at I pM, while the sample consumption is reduced to 5 mu l. The proposed approach shows high selectivity and minimizes the nonspecific adsorption, so that it was used for the detection of target protein in the human serum sample. Such an aptamer-based biosensor provides a promising strategy for screening biomarkers at ultratrace levels in the complex matrices. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:38 / 40
页数:3
相关论文
共 22 条
[1]   A novel electrochemical detection method for aptamer biosensors [J].
Bang, GS ;
Cho, S ;
Kim, BG .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) :863-870
[2]   SELECTION OF SINGLE-STRANDED-DNA MOLECULES THAT BIND AND INHIBIT HUMAN THROMBIN [J].
BOCK, LC ;
GRIFFIN, LC ;
LATHAM, JA ;
VERMAAS, EH ;
TOOLE, JJ .
NATURE, 1992, 355 (6360) :564-566
[3]   Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads [J].
Centi, Sonia ;
Tombelli, Sara ;
Minunni, Maria ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1466-1473
[4]   Versatile immunosensor using CdTe quantum dots as electrochemical and fluorescent labels [J].
Cui, Rongjing ;
Pan, Hong-Cheng ;
Zhu, Jun-Jie ;
Chen, Hong-Yuan .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8494-8501
[5]   Quantum-dot/aptamer-based ultrasensitive multi-analyte electrochemical biosensor [J].
Hansen, JA ;
Wang, J ;
Kawde, AN ;
Xiang, Y ;
Gothelf, KV ;
Collins, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (07) :2228-2229
[6]   Biochemistry - Adaptive recognition by nucleic acid aptamers [J].
Hermann, T ;
Patel, DJ .
SCIENCE, 2000, 287 (5454) :820-825
[7]   Novel electrochemical sensor system for protein using the aptamers in sandwich manner [J].
Ikebukuro, K ;
Kiyohara, C ;
Sode, K .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2168-2172
[8]   Sensitive detection of protein by an aptamer-based label-free fluorescing molecular switch [J].
Li, Bingling ;
Wei, Hui ;
Dong, Shaojun .
CHEMICAL COMMUNICATIONS, 2007, (01) :73-75
[9]   Nanocrystal-based bioelectronic coding of single nucleotide polymorphisms [J].
Liu, GD ;
Lee, TMH ;
Wang, JS .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (01) :38-39
[10]   Different strategies to develop an electrochemical thrombin aptasensor [J].
Mir, M ;
Vreeke, M ;
Katakis, L .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (03) :505-511