An adaptive filter for suppression of cardiac and respiratory noise in MRI time series data

被引:82
作者
Deckers, Roel H. R.
van Gelderen, Peter
Ries, Mario
Barret, Olivier
Duyn, Jeff H.
Ikonomidou, Vasiliki N.
Fukunaga, Masaki
Glover, Gary H.
de Zwart, Jacco A.
机构
[1] NINDS, LFMI, Adv MRI Sect, NIH, Bethesda, MD 20892 USA
[2] Eindhoven Univ Technol, Dept Biomed Engn, Biomed NMR, NL-5600 MB Eindhoven, Netherlands
[3] Univ Bordeaux 2, CNRS, ERT, F-33076 Bordeaux, France
[4] Stanford Univ, Sch Med, Radiol Sci Lab, Palo Alto, CA 94304 USA
关键词
physiologic noise; artifacts; filtering; temporal stability; fMRI;
D O I
10.1016/j.neuroimage.2006.08.006
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The quality of MRI time series data, which allows the study of dynamic processes, is often affected by confounding sources of signal fluctuation, including the cardiac and respiratory cycle. An adaptive filter is described, reducing these signal fluctuations as long as they are repetitive and their timing is known. The filter, applied in image domain, does not require temporal oversampling of the artifact-related fluctuations. Performance is demonstrated for suppression of cardiac and respiratory artifacts in 10-minute brain scans on 6 normal volunteers. Experimental parameters resemble a typical fMRI experiment (17 slices; 1700 ms TR). A second dataset was acquired at a rate well above the Nyquist frequency for both cardiac and respiratory cycle (single slice; 100 ins TR), allowing identification of artifacts specific to the cardiac and respiratory cycles, aiding assessment of filtering performance. Results show significant reduction in temporal standard deviation (SDt) in all subjects. For an 6 datasets with 1700 ms TR combined, the filtering method resulted in an average reduction in SDt of 9.2% in 2046 voxels substantially affected by respiratory artifacts, and 12.5% for the 864 voxels containing substantial cardiac artifacts. The maximal SDt reduction achieved was 52.7% for respiratory and 55.3% for cardiac filtering. Performance was found to be at least equivalent to the previously published RETROICOR method. Furthermore, the interaction between the filter and fMRI activity detection was investigated using Monte Carlo simulations, demonstrating that filtering algorithms introduce a systematic error in the detected BOLD-related signal change if applied sequentially. It is demonstrated that this can be overcome by combining physiological artifact filtering and detection of BOLD-related signal changes simultaneously. Visual fMRI data from 6 volunteers were analyzed with and without the filter proposed here. Inclusion of the cardio-respiratory regressors in the design matrix yielded a 4.6% t-score increase and 4.0% increase in the number of significantly activated voxels. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1072 / 1081
页数:10
相关论文
共 24 条
[1]   FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI [J].
BISWAL, B ;
YETKIN, FZ ;
HAUGHTON, VM ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :537-541
[2]   Reduction of physiological fluctuations in fMRI using digital filters [J].
Biswal, B ;
DeYoe, EA ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :107-113
[3]   Scalable multichannel MRI data acquisition system [J].
Bodurka, J ;
Ledden, PJ ;
van Gelderen, P ;
Chu, RX ;
de Zwart, JA ;
Morris, D ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :165-171
[4]   Noise suppression digital filter for functional magnetic resonance imaging based on image reference data [J].
Buonocore, MH ;
Maddock, RJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :456-469
[5]   Localization of cardiac-induced signal change in fMRI [J].
Dagli, MS ;
Ingeholm, JE ;
Haxby, JV .
NEUROIMAGE, 1999, 9 (04) :407-415
[6]  
Dale AM, 1997, HUM BRAIN MAPP, V5, P329, DOI 10.1002/(SICI)1097-0193(1997)5:5<329::AID-HBM1>3.0.CO
[7]  
2-5
[8]   Signal-to-noise ratio and parallel Imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla [J].
de Zwart, JA ;
Ledden, PJ ;
van Gelderen, P ;
Bodurka, J ;
Chu, RX ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :22-26
[9]   Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging [J].
de Zwart, JA ;
van Gelderen, P ;
Kellman, P ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) :1011-1020
[10]  
DURBIN J, 1971, BIOMETRIKA, V58, P1