Reliability and validity of inexpensive and easily administered anthropometric clinical evaluation methods of postural asymmetry measurement in adolescent idiopathic scoliosis: a systematic review

被引:36
作者
Prowse, Ashleigh [1 ]
Pope, Rodney [1 ]
Gerdhem, Paul [2 ,3 ]
Abbott, Allan [4 ,5 ]
机构
[1] Bond Univ, Fac Hlth Sci & Med, Dept Physiotherapy, Robina, Qld, Australia
[2] Karolinska Univ Hosp, Dept Orthopaed, Stockholm, Sweden
[3] Karolinska Inst, Dept Clin Sci Intervent & Technol CLINTEC, Stockholm, Sweden
[4] Karolinska Univ Hosp, Dept Physiotherapy, Huddinge, Sweden
[5] Linkoping Univ, Fac Hlth Sci, Dept Med & Hlth Sci, Div Physiotherapy, Linkoping, Sweden
关键词
Reliability; Validity; Adolescent idiopathic scoliosis; Postural asymmetry; Measurement; Anthropometric; SCOLIOMETER MEASUREMENTS; SPINAL CURVATURE; COBB ANGLE; RIB HUMP; TRUNK; DEFORMITY; TOOL; PREDICTION; ACCURACY; IPHONE;
D O I
10.1007/s00586-015-3961-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
As accurate and reproducible measurements of spinal curvature are crucial in the examination of patients with adolescent idiopathic scoliosis (AIS), this systematic review aims to report on the reliability and validity of a range of inexpensive and easily administered anthropometric methods of postural asymmetry measurement in an AIS population, to inform practice in a clinical setting. A systematic search of health research databases located studies assessing reliability and validity of inexpensive and easily administered anthropometric measures. Fourteen studies satisfied eligibility criteria. The methodological quality of included studies ranged from low to high. Validity studies were of moderate to high quality. In total, nine clinically applicable, inexpensive and easily administered anthropometric methods were identified, for assessing AIS curvature. All methods demonstrated high to very high inter-observer and intra-observer reliability. Reported criterion validity of the scoliometer and 2D photographs, when compared to Cobb angle assessed from radiographs, ranged from low to very high. iPhone measurements correlated well with scoliometer measurements. 2D photography results had a moderate to high correlation with 3D topography results. Overall, strong levels of evidence exist for iPhone and scoliometer measurements, with a high to very high reliability and moderate to very high validity. Moderate levels of evidence exist for scoliometer with mathematical formula and clinical examination with moderate and low validity, respectively. Limited evidence exists for aesthetic tools TRACE and AI and 2D photography. These results indicate there are accurate and reproducible anthropometric measures that are inexpensive and applicable in therapy settings to assess postural asymmetry; however, these only exist for measurement in the transverse plane, despite 3D characteristics of AIS. Further research is required into an inexpensive and easily administered method that can assess postural asymmetry in all anatomical planes.
引用
收藏
页码:450 / 466
页数:17
相关论文
共 51 条
[1]
VALIDITY AND RELIABILITY TESTING OF THE SCOLIOMETER [J].
AMENDT, LE ;
AUSEELLIAS, KL ;
EYBERS, JL ;
WADSWORTH, CT ;
NIELSEN, DH ;
WEINSTEIN, SL .
PHYSICAL THERAPY, 1990, 70 (02) :108-117
[2]
Balg F, 2014, J PEDIATR ORTHOPED, V34, P774, DOI 10.1097/BPO.0000000000000195
[3]
Inter and intra-rater reliability of the scoliometer [J].
Bonagamba, Guilherme H. ;
Coelho, Daniel M. ;
de Oliveira, Anamaria S. .
BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2010, 14 (05) :432-437
[4]
Clinical instruments: reliability and validity critical appraisal [J].
Brink, Yolandi ;
Louw, Quinette A. .
JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2012, 18 (06) :1126-1132
[5]
The quality of evidence of psychometric properties of three-dimensional spinal posture-measuring instruments [J].
Brink, Yolandi ;
Louw, Quinette ;
Grimmer-Somers, Karen .
BMC MUSCULOSKELETAL DISORDERS, 2011, 12
[6]
AN OBJECTIVE CRITERION FOR SCOLIOSIS SCREENING [J].
BUNNELL, WP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (09) :1381-1387
[7]
School screening for scoliosis: can surface topography replace examination with scoliometer? [J].
Chowanska, Joanna ;
Kotwicki, Tomasz ;
Rosadzinski, Krzysztof ;
Sliwinski, Zbigniew .
SCOLIOSIS AND SPINAL DISORDERS, 2012, 7
[8]
Coelho DM, 2013, BRAZ J PHYS THER, V17, P179
[9]
A study of the diagnostic accuracy and reliability of the scoliometer and Adam's forward bend test [J].
Côté, P ;
Kreitz, BG ;
Cassidy, JD ;
Dzus, AK ;
Martel, J .
SPINE, 1998, 23 (07) :796-802
[10]
Validity and Reproducibility of the Measurements Obtained Using the Flexicurve Instrument to Evaluate the Angles of Thoracic and Lumbar Curvatures of the Spine in the Sagittal Plane [J].
de Oliveira, Tatiana Scheeren ;
Candotti, Claudia Tarrago ;
La Torre, Marcelo ;
Tonin Pelinson, Patricia Paula ;
Furlanetto, Tassia Silveira ;
Kutchak, Fernanda Machado ;
Loss, Jefferson Fagundes .
REHABILITATION RESEARCH AND PRACTICE, 2012, 2012