Micro free-flow IEF enhanced by active cooling and functionalized gels

被引:49
作者
Albrecht, Jacob W. [1 ]
Jensen, Klavs F. [1 ]
机构
[1] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
关键词
free-flow IEF; microfabrication; protein separation;
D O I
10.1002/elps.200600436
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rapid free-flow IEF is achieved in a microfluidic device by separating the electrodes from the focusing region with porous buffer regions. Moving the electrodes outside enables the use of large electric fields without the detrimental effects of bubble formation in the active region. The anode and cathode porous buffer regions, which are formed by acrylamide functionalized with immobilized pH groups, allow ion transport while providing buffering capacity. Thermoelectric cooling mitigates the effects of Joule heating on sample focusing at high field strengths (similar to 500 V/cm). This localized cooling was observed to increase device performance. Rapid focusing of low-molecular-weight pI markers and Protein G-mouse IgG complexes demonstrate the versatility of the technique. Simulations provide insight into and predict device performance based on a well-defined sample composition.
引用
收藏
页码:4960 / 4969
页数:10
相关论文
共 39 条
[11]   Photopolymerized cross-linked polyacrylamide gels for on-chip protein sizing [J].
Herr, AE ;
Singh, AK .
ANALYTICAL CHEMISTRY, 2004, 76 (16) :4727-4733
[12]   Capillary isoelectric focusing with UV-induced fluorescence detection [J].
Horká, M ;
Willimann, T ;
Blum, M ;
Nording, P ;
Friedl, Z ;
Slais, K .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :65-71
[13]   Isotachophoresis in free-flow using a miniaturized device [J].
Janasek, Dirk ;
Schilling, Michael ;
Franzke, Joachim ;
Manz, Andreas .
ANALYTICAL CHEMISTRY, 2006, 78 (11) :3815-3819
[14]   Free-flow zone electrophoresis and isoelectric focusing using a microfabricated glass device with ion permeable membranes [J].
Kohlheyer, D ;
Besselink, GAJ ;
Schlautmann, S ;
Schasfoort, RBM .
LAB ON A CHIP, 2006, 6 (03) :374-380
[15]   A microfabricated device for subcellular organelle sorting [J].
Lu, H ;
Gaudet, S ;
Schmidt, MA ;
Jensen, KF .
ANALYTICAL CHEMISTRY, 2004, 76 (19) :5705-5712
[16]   Concentration and separation of proteins in microfluidic channels on the basis of transverse IEF [J].
Macounová, K ;
Cabrera, CR ;
Yager, P .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1627-1633
[17]  
Merkel TC, 2000, J POLYM SCI POL PHYS, V38, P415, DOI 10.1002/(SICI)1099-0488(20000201)38:3<415::AID-POLB8>3.0.CO
[18]  
2-Z
[19]   Protein fractionation in a multicompartment device using Off-Gel™ isoelectric focusing [J].
Michel, PE ;
Reymond, F ;
Arnaud, IL ;
Josserand, J ;
Girault, HH ;
Rossier, JS .
ELECTROPHORESIS, 2003, 24 (1-2) :3-11
[20]   EXPERIMENTAL AND THEORETICAL DYNAMICS OF ISOELECTRIC-FOCUSING .3. TRANSIENT MULTI-PEAK APPROACH TO EQUILIBRIUM OF PROTEINS IN SIMPLE BUFFERS [J].
MOSHER, RA ;
THORMANN, W ;
KUHN, R ;
WAGNER, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 478 (01) :39-49