An automatic flow-injection analysis system for determining phosphate ion in river water using pyruvate oxidase G (from Aerococcus viridans)

被引:44
作者
Nakamura, H
Tanaka, H
Hasegawa, M
Masuda, Y
Arikawa, Y
Nomura, Y
Ikebukuro, K
Karube, I
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
[2] Sci Univ Tokyo, Fac Engn, Dept Ind Chem, Shinjuku Ku, Tokyo 1628601, Japan
[3] Japan Womens Univ, Dept Chem & Biol Sci, Fac Sci, Mejiro Ku, Tokyo 1120015, Japan
关键词
phosphate ion; chemiluminescence; pyruvate oxidase G; Arthromyces ramosus peroxidase; N-hydroxysuccinicacidimido gel; flow-injection analysis; activated carbon treatment; river water;
D O I
10.1016/S0039-9140(99)00137-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated flow-injection system combining a pyruvate oxidase reaction and chemiluminescence for the detection of phosphate ion in river water has been developed. In this research, we used pyruvate oxidase G (PyrOxG), from Aerococcus viridans, immobilizing it on N-hydroxysuccinicacidimido beads without a cross-linker. In this sensor system, which was constructed as a trial system of desktop type, the temperature was precisely controlled. After the sensor system was optimized, a calibration curve was obtained with a detection limit of 96 nM phosphate ion, a range between 96 nM and 32 mu M phosphate ion, and a relative standard deviation of 2.3% (n = 5) at 25 degrees C. The sensitivity of this sensor was sufficient to determine the maximal permissible phosphate-ion concentration in the environmental waters of Japan (0.32 mu M). In addition, the sensor could determine the calibration curves between 0.16 and 32 mu M phosphate ion (five points, n = 3; averaged correlation, r = 1.00) for at least 2 weeks, demonstrating enough stability for practical use. Furthermore, we investigated the influence on the sensor response of dissolved substances in river water such as metal ions, heavy metal ions, inorganic ions, and organic compounds. Treatment with activated carbon could improve the response of the sensor when inhibited by dissolved substances in river water, except for manganese ion and uric acid. The sensor system could determine the concentrations of phosphate ion in various samples of river water from the Tone River. The results obtained by this sensor system and the modified molybdenum blue method were compared, and good correlation (r = 0.94) was obtained. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:799 / 807
页数:9
相关论文
共 10 条
  • [1] A NOVEL ENZYME SENSOR FOR THE DETERMINATION OF INORGANIC-PHOSPHATE
    CONRATH, N
    GRUNDIG, B
    HUWEL, S
    CAMMANN, K
    [J]. ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) : 47 - 52
  • [2] Highly sensitive chemiluminescence flow injection analysis system using microbial peroxidase and a photodiode detector
    Hayashi, KJ
    Sasaki, S
    Ikebukuro, K
    Karube, I
    [J]. ANALYTICA CHIMICA ACTA, 1996, 329 (1-2) : 127 - 134
  • [3] A novel biosensor system for the determination of phosphate
    Ikebukuro, K
    Nishida, R
    Yamamoto, H
    Arikawa, Y
    Nakamura, H
    Suzuki, M
    Kubo, I
    Takeuchi, T
    Karube, I
    [J]. JOURNAL OF BIOTECHNOLOGY, 1996, 48 (1-2) : 67 - 72
  • [4] PHOSPHORUS IN FLOWING WATERS
    KEUP, LE
    [J]. WATER RESEARCH, 1968, 2 (05) : 373 - &
  • [5] MISAKI H, 1983, Patent No. 5840465
  • [6] A chemiluminescent FIA biosensor for phosphate ion monitoring using pyruvate oxidase
    Nakamura, H
    Ikebukuro, K
    McNiven, S
    Karube, I
    Yamamoto, H
    Hayashi, K
    Suzuki, M
    Kubo, I
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10) : 959 - 966
  • [7] SCHULMANN SG, 1985, MOL LUMINESCENCE S 1, P463
  • [8] Reagentless phosphate ion sensor system for environmental monitoring
    Suzuki, M
    Kurata, H
    Inoue, Y
    Shin, H
    Kubo, I
    Nakamura, H
    Ikebukuro, K
    Karube, I
    [J]. DENKI KAGAKU, 1998, 66 (06): : 579 - 583
  • [9] DETERMINATION OF PHOSPHATE IONS WITH AN ENZYME SENSOR SYSTEM
    WATANABE, E
    ENDO, H
    TOYAMA, K
    [J]. BIOSENSORS, 1988, 3 (05) : 297 - 306
  • [10] BIOSENSOR FOR SENSITIVE PHOSPHATE DETECTION
    WOLLENBERGER, U
    SCHUBERT, F
    SCHELLER, FW
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) : 412 - 415