Micro hole-based cell chip with impedance spectroscopy

被引:49
作者
Cho, Sungbo [1 ]
Thielecke, Hagen [1 ]
机构
[1] Fraunhofer Inst Biomed Engn, D-66386 St Ingbert, Germany
关键词
cell growth; cell positioning; cytotoxicity test; electrical biosensor; FEM simulation;
D O I
10.1016/j.bios.2006.08.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electric fields can be used for the characterisation and manipulation of single biological cells. One approach to avoid the effect of electrode polarisation is to position cells on micro holes and to apply the electrical fields via the micro holes. For a correct characterisation and optimal manipulation, the electrical properties of the micro hole/cell interface must be understood. In this article, the electrical characteristics of a micro hole-based cell chip were investigated. By FEM simulation, it was estimated that the impedance measurement with micro hole-based chip is most dependent on the cell adhesion/spread rather than the intra-cellular space (contribution of intra-cellular space to the total impedance: 0.07% at 1 kHz, 0.3% at 1 MHz). The effective frequency range in which the impedance related with cell state on the hole considerably influences total measured impedance was below several kiloHertz. From the experiments, it was shown that the impedance of cell cultured on the hole at the low frequency range is increased during the increase of cultivation period, but is sensitively decreased after applying only several nanolitres of culture medium including 5% dimethlysulfoxide. This micro hole-based chip has a potential for monitoring the cell growth and the membrane integrity of even single cell without any labelling. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1764 / 1768
页数:5
相关论文
共 15 条
[1]  
DEBOER RW, 1978, MED BIOL ENG COMPUT, V16, P1, DOI 10.1007/BF02442925
[2]   Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures [J].
Ehret, R ;
Baumann, W ;
Brischwein, M ;
Schwinde, A ;
Stegbauer, K ;
Wolf, B .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) :29-41
[3]   A MORPHOLOGICAL BIOSENSOR FOR MAMMALIAN-CELLS [J].
GIAEVER, I ;
KEESE, CR .
NATURE, 1993, 366 (6455) :591-592
[4]   Imaging of cell/substrate contacts of living cells with surface plasmon resonance microscopy [J].
Giebel, KF ;
Bechinger, C ;
Herminghaus, S ;
Riedel, M ;
Leiderer, P ;
Weiland, U ;
Bastmeyer, M .
BIOPHYSICAL JOURNAL, 1999, 76 (01) :509-516
[5]   Microfabricated electroporation chip for single cell membrane permeabilization [J].
Huang, Y ;
Rubinsky, B .
SENSORS AND ACTUATORS A-PHYSICAL, 2001, 89 (03) :242-249
[6]   Instantaneous, quantitative single-cell viability assessment by electrical evaluation of cell membrane integrity with microfabricated devices [J].
Huang, Y ;
Sekhon, NS ;
Borninski, J ;
Chen, N ;
Rubinsky, B .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 105 (01) :31-39
[7]  
Li Nianzhen, 2003, Crit Rev Biomed Eng, V31, P423, DOI 10.1615/CritRevBiomedEng.v31.i56.20
[8]   Monitoring motility, spreading, and mortality of adherent insect cells using an impedance sensor [J].
Luong, JHT ;
Habibi-Rezaei, M ;
Meghrous, J ;
Xiao, C ;
Male, KB ;
Kamen, A .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1844-1848
[9]  
MACK A, 2001, TRENDS BIOTECHNOL, V20, P56
[10]  
Malmivuo J., 1995, Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields, P365, DOI 10.1093/acprof:oso/9780195058239.001.0001