Spectral irradiance comparison using a multi-wavelength filter radiometer

被引:14
作者
Liu, Y. J.
Xu, G.
Ojanen, M. [1 ]
Ikonen, E. [1 ]
机构
[1] Aalto Univ, Metrol Res Inst, Helsinki, Finland
关键词
REALIZATION; SCALE; NM;
D O I
10.1088/0026-1394/46/4/S09
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An automatic multi-wavelength filter radiometer (MWFR) was developed at the National Metrology Centre (NMC) of Singapore to realize the spectral irradiance scale in the wavelength range from 250 nm to 1600 nm. The UV-VIS range (250 nm to 900 nm) is covered by a silicon trap detector with 17 filters, while the near IR range (900 nm to 1600 nm) is covered by an InGaAs photodiode with 7 filters. A complete run of measurements at all 24 wavelength points takes only 12 min. The spectral irradiance scales of NMC and MIKES/TKK (Finland) in the spectral range from 280 nm to 900 nm were compared successfully using this instrument. Measurement results of three standard lamps calculated using MIKES/TKK's algorithm showed excellent repeatability and very good agreement with their assigned values. It is concluded that, compared with the conventional monochromator based spectroradiometers, a properly designed MWFR with sufficient spectral coverage is a good alternative instrument for spectral irradiance comparison owing to its faster speed and better short-term reproducibility.
引用
收藏
页码:S181 / S185
页数:5
相关论文
共 9 条
[1]  
*ASTM, 1995, E38784 ASTM, P755
[2]   Realization of a filter radiometer-based irradiance scale with high accuracy in the region from 286 nm to 901 nm [J].
Durak, M ;
Samadov, F .
METROLOGIA, 2004, 41 (06) :401-406
[3]   Spectral reflectance of silicon photodiodes [J].
Haapalinna, A ;
Karha, P ;
Ikonen, E .
APPLIED OPTICS, 1998, 37 (04) :729-732
[4]   Spectral irradiance measurements of tungsten lamps with filter radiometers in the spectral range 290 nm to 900 nm [J].
Kübarsepp, T ;
Kärhä, P ;
Manoocheri, F ;
Nevas, S ;
Ylianttila, L ;
Ikonen, E .
METROLOGIA, 2000, 37 (04) :305-312
[5]   Spectral-irradiance scale based on radiometric black-body temperature measurements [J].
Sperfeld, P ;
Raatz, KH ;
Nawo, B ;
Moller, W ;
Metzdorf, J .
METROLOGIA, 1996, 32 (06) :435-439
[6]   The characterization of a high-temperature black body as the basis for the NPL spectral-irradiance scale [J].
White, M ;
Fox, NP ;
Ralph, VE ;
Harrison, NJ .
METROLOGIA, 1996, 32 (06) :431-434
[7]  
WILKINSON F, 2006, METROLOGIA S, V43
[8]  
Woolliams Emma R., 2006, Metrologia, V43, P02003, DOI [DOI 10.1088/0026-1394/43/1A/02003, 10.1088/0026-1394/43/1A/02003]
[9]   The realization of the NIST detector-based spectral irradiance scale [J].
Yoon, HW ;
Gibson, CE ;
Barnes, PY .
METROLOGIA, 2003, 40 (01) :S172-S176