Volta potential phase plate for in-focus phase contrast transmission electron microscopy

被引:337
作者
Danev, Radostin [1 ]
Buijsse, Bart [2 ]
Khoshouei, Maryam [1 ]
Plitzko, Juergen M. [1 ,3 ]
Baumeister, Wolfgang [1 ]
机构
[1] Max Planck Inst Biochem, Dept Mol Struct Biol, D-82152 Martinsried, Germany
[2] FEI, NL-5651 GG Eindhoven, Netherlands
[3] Univ Utrecht, Bijvoet Ctr Biomol Res, NL-3584 CH Utrecht, Netherlands
关键词
TEM; phase plate; Volta potential; phase contrast; cryo-EM; THIN-FILMS; TOMOGRAPHY;
D O I
10.1073/pnas.1418377111
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
We describe a phase plate for transmission electron microscopy taking advantage of a hitherto-unknown phenomenon, namely a beam-induced Volta potential on the surface of a continuous thin film. The Volta potential is negative, indicating that it is not caused by beam-induced electrostatic charging. The film must be heated to similar to 200 degrees C to prevent contamination and enable the Volta potential effect. The phase shift is created "on the fly" by the central diffraction beam eliminating the need for precise phase plate alignment. Images acquired with the Volta phase plate (VPP) show higher contrast and unlike Zernike phase plate images no fringing artifacts. Following installation into the microscope, the VPP has an initial settling time of about a week after which the phase shift behavior becomes stable. The VPP has a long service life and has been used for more than 6 mo without noticeable degradation in performance. The mechanism underlying the VPP is the same as the one responsible for the degradation over time of the performance of thin-film Zernike phase plates, but in the VPP it is used in a constructive way. The exact physics and/or chemistry behind the process causing the Volta potential are not fully understood, but experimental evidence suggests that radiation-induced surface modification combined with a chemical equilibrium between the surface and residual gases in the vacuum play an important role.
引用
收藏
页码:15635 / 15640
页数:6
相关论文
共 25 条
[1]
Work functions and surface functional groups of multiwall carbon nanotubes [J].
Ago, H ;
Kugler, T ;
Cacialli, F ;
Salaneck, WR ;
Shaffer, MSP ;
Windle, AH ;
Friend, RH .
JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (38) :8116-8121
[2]
Design of a hybrid double-sideband/single-sideband (schlieren) objective aperture suitable for electron microscopy [J].
Buijsse, Bart ;
van Laarhoven, Frank M. H. M. ;
Schmid, Andreas K. ;
Cambie, Rossana ;
Cabrini, Stefano ;
Jin, Jian ;
Glaeser, Robert M. .
ULTRAMICROSCOPY, 2011, 111 (12) :1688-1695
[3]
Visualizing virus assembly intermediates inside marine cyanobacteria [J].
Dai, Wei ;
Fu, Caroline ;
Raytcheva, Desislava ;
Flanagan, John ;
Khant, Htet A. ;
Liu, Xiangan ;
Rochat, Ryan H. ;
Haase-Pettingell, Cameron ;
Piret, Jacqueline ;
Ludtke, Steve J. ;
Nagayama, Kuniaki ;
Schmid, Michael F. ;
King, Jonathan A. ;
Chiu, Wah .
NATURE, 2013, 502 (7473) :707-+
[4]
Transmission electron microscopy with Zernike phase plate [J].
Danev, R ;
Nagayama, K .
ULTRAMICROSCOPY, 2001, 88 (04) :243-252
[5]
Optimizing the phase shift and the cut-on periodicity of phase plates for TEM [J].
Danev, Radostin ;
Nagayama, Kuniaki .
ULTRAMICROSCOPY, 2011, 111 (08) :1305-1315
[6]
PHASE PLATES FOR TRANSMISSION ELECTRON MICROSCOPY [J].
Danev, Radostin ;
Nagayama, Kuniaki .
METHODS IN ENZYMOLOGY, VOL 481: CRYO-EM, PART A - SAMPLE PREPARATION AND DATA COLLECTION, 2010, 481 :343-369
[7]
Zernike phase contrast cryo-electron tomography [J].
Danev, Radostin ;
Kanamaru, Shuji ;
Marko, Michael ;
Nagayama, Kuniaki .
JOURNAL OF STRUCTURAL BIOLOGY, 2010, 171 (02) :174-181
[8]
Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy [J].
Danev, Radostin ;
Glaeser, Robert M. ;
Nagayama, Kuniaki .
ULTRAMICROSCOPY, 2009, 109 (04) :312-325
[9]
Electric charging of thin films measured using the contrast transfer function [J].
Danov, K ;
Danev, R ;
Nagayama, K .
ULTRAMICROSCOPY, 2001, 87 (1-2) :45-54
[10]
Experimental characterization and mitigation of specimen charging on thin films with one conducting layer [J].
Downing, KH ;
McCartney, MR ;
Glaeser, RM .
MICROSCOPY AND MICROANALYSIS, 2004, 10 (06) :783-789