X-ray scatter suppression algorithm for cone beam volume CT

被引:37
作者
Ning, RL [1 ]
Tang, XY [1 ]
Conover, DL [1 ]
机构
[1] Univ Rochester, Dept Radiol, Rochester, NY 14642 USA
来源
MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING | 2002年 / 4682卷
关键词
scatter; scatter correction; antiscatter grid; cone beam reconstruction; flat panel detector; cone beam volume CT;
D O I
10.1117/12.465628
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Developing and optimizing an x-ray scatter control and reduction technique is one big challenge for cone beam volume computed tomography (CBVCT) because CBVCT will be much less immune to scatter than fan-beam CT. X-ray Scatter reduces image contrast, increases image noise and introduces reconstruction error into CBVCT. To reduce scatter interference, a practical algorithm that is based upon the beam stop array technique and image sequence processing has been developed on a flat panel detector-based CBVCT prototype scanner. This paper presents beam stop array-based scatter correction algorithm and the evaluation results through phantom studies. The results indicate that the beam stop array-based scatter correction algorithm is practical and effective to reduce and correct x-ray scatter for a CBVCT imaging task.
引用
收藏
页码:774 / 781
页数:2
相关论文
共 11 条
[1]
Cone-beam computed tomography with a flat-panel imager: Initial performance characterization [J].
Jaffray, DA ;
Siewerdsen, JH .
MEDICAL PHYSICS, 2000, 27 (06) :1311-1323
[2]
Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation [J].
Ning, R ;
Chen, B ;
Yu, RF ;
Conover, D ;
Tang, XY ;
Ning, Y .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) :949-963
[3]
Flat panel detector-based cone beam volume CT imaging: detector evaluation [J].
Ning, R ;
Tang, XY ;
Yu, RF ;
Conover, D ;
Zhang, DH .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :192-203
[4]
NING R, 2001, SPIE P, V4320
[5]
Real time flat panel detector-based volume tomographic angiography imaging: Detector evaluation [J].
Ning, RL ;
Colbeth, R ;
Chen, B ;
Yu, RF ;
Conover, D ;
Ning, Y ;
Blouir, C .
MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 :396-407
[6]
Cone-beam CT with a flat-panel imager: Noise considerations for fully 3-D computed tomography [J].
Siewerdsen, JH ;
Jaffray, DA .
MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 :408-416
[7]
Investigation into the influence of x-ray scatter on the imaging performance of an x-ray flat panel imager based cone beam volume CT [J].
Tang, XY ;
Ning, R ;
Yu, RF ;
Conover, D .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :851-860
[8]
Cane beam volume CT image artifacts caused by defective cells in x-ray flat panel imagers and the artifact removal using a wavelet-analysis-based algorithm [J].
Tang, XY ;
Ning, R ;
Yu, RF ;
Conover, D .
MEDICAL PHYSICS, 2001, 28 (05) :812-825
[9]
A 2D wavelet-analysis-based calibration technique for flat panel imaging detectors: Application in cone beam volume CT [J].
Tang, XY ;
Ning, RL ;
Yu, RF ;
Conover, D .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :806-816
[10]
A cone beam filtered backprojection (CB-FBP) reconstruction algorithm for a circle-plus-two-arc orbit [J].
Tang, XY ;
Ning, R .
MEDICAL PHYSICS, 2001, 28 (06) :1042-1055