Duplex ultrasonography in assessing restenosis of renal artery stents

被引:31
作者
Bakker, J [1 ]
Beutler, JJ [1 ]
Elgersma, OEH [1 ]
de Lange, EE [1 ]
de Kort, GAP [1 ]
Beek, FJA [1 ]
机构
[1] Univ Utrecht Hosp, Dept Radiol, NL-3584 CX Utrecht, Netherlands
关键词
renal arteries; stenosis or obstruction; stents and prostheses; duplex ultrasonography;
D O I
10.1007/s002709900435
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To determine the accuracy and optimal threshold values of duplex ultrasonography (US) in assessing restenosis of renal artery stents. Methods: Twenty-four consecutive patients with 33 renal arteries that had previously been treated with placement of a Palmaz stent underwent duplex US prior to intraarterial digital subtraction angiography (DSA), which was the reference standard. Diagnostic accuracy of in-stent peak systolic velocity (PSV) and reno-aortic ratio (RAR = PSV renal stent/PSV aorta) in detecting > 50% in-stent restenosis were evaluated by the receiver operating characteristic curve. Sensitivity and specificity were determined using the optimal threshold values, and using published threshold values: RAR > 3.5 and in-stent PSV > 180 cm/sec. Results: Six examinations were technically inadequate. Nine stents had residual or restenosis > 50% at DSA. The two duplex parameters were equally accurate since areas under the curves were similar (0.943). With optimal threshold values of 226 cm/sec for PSV and 2.7 for RAR, sensitivities and specificities were 100% and 90%, and 100% and 84%, respectively. Using the published duplex criteria resulted in sensitivities and specificities of 100% and 74% for PSV, and 50% and 89% for RAR. Conclusion: Duplex US is a sensitive modality for detecting in-stent restenosis if laboratory-specific threshold values are used.
引用
收藏
页码:475 / 480
页数:6
相关论文
共 43 条
  • [31] PALMAZ STENT IN ATHEROSCLEROTIC STENOSES INVOLVING THE OSTIA OF THE RENAL-ARTERIES - PRELIMINARY-REPORT OF A MULTICENTER STUDY
    REES, CR
    PALMAZ, JC
    BECKER, GJ
    EHRMAN, KO
    RICHTER, GM
    NOELDGE, G
    KATZEN, BT
    DAKE, MD
    SCHWARTEN, DE
    [J]. RADIOLOGY, 1991, 181 (02) : 507 - 514
  • [32] Percutaneous renal artery stent placement for hypertension and azotemia: Pilot study
    Rundback, JH
    Jacobs, JM
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1996, 28 (02) : 214 - 219
  • [33] Restenosis of peripheral stents and stent grafts as revealed by intravascular sonography:: In vivo comparison with angiography
    Schwarzenberg, H
    Müller-Hülsbeck, S
    Glüer, CC
    Wesner, F
    Heller, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) : 1181 - 1185
  • [34] PERCUTANEOUS TRANS-LUMINAL RENAL ANGIOPLASTY IN RENOVASCULAR HYPERTENSION DUE TO ATHEROMA OR FIBROMUSCULAR DYSPLASIA
    SOS, TA
    PICKERING, TG
    SNIDERMAN, K
    SADDEKNI, S
    CASE, DB
    SILANE, MF
    VAUGHAN, ED
    LARAGH, JH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1983, 309 (05) : 274 - 279
  • [35] DUPLEX IMAGING FOR THE DETECTION OF RENAL-ARTERY STENOSIS
    STRANDNESS, DE
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (04) : 674 - 678
  • [36] STROTZER M, 1995, ACTA RADIOL, V36, P243
  • [37] Stent placement after iliac angioplasty: Comparison of hemodynamic and angiographic criterial
    Tetteroo, E
    vanEngelen, AD
    Spithoven, JH
    Tielbeek, AV
    vanderGraaf, Y
    Mali, WPTM
    [J]. RADIOLOGY, 1996, 201 (01) : 155 - 159
  • [38] Results of percutaneous transluminal angioplasty for atherosclerotic renal artery stenosis: A follow-up study with duplex ultrasonography
    Tullis, MJ
    Zierler, RE
    Glickerman, DJ
    Bergelin, RO
    CantwellGab, K
    Strandness, DE
    [J]. JOURNAL OF VASCULAR SURGERY, 1997, 25 (01) : 46 - 54
  • [39] Arterial stenting and balloon angioplasty in ostial atherosclerotic renovascular disease: a randomised trial
    van de Ven, PJG
    Kaatee, R
    Beutler, JJ
    Beek, FJA
    Woittiez, AJJ
    Buskens, E
    Koomans, HA
    Mali, WPT
    [J]. LANCET, 1999, 353 (9149) : 282 - 286
  • [40] TRANSLUMINAL VASCULAR STENT FOR OSTIAL ATHEROSCLEROTIC RENAL-ARTERY STENOSIS
    VANDEVEN, PJG
    BEUTLER, JJ
    KAATEE, R
    BEEK, FJA
    MALI, WPTM
    GEYSKES, GG
    KOOMANS, HA
    [J]. LANCET, 1995, 346 (8976): : 672 - 674