Percutaneous pulmonary valve replacement: 3-month evaluation of self-expanding valved stents

被引:24
作者
Attmann, Tim
Quaden, Rene
Jahnke, Thomas
Muller-Hulsbeck, Stefan
Boening, Andreas
Cremer, Jochen
Lutter, Georg
机构
[1] Univ Kiel, Sch Med, Dept Cardiovasc Surg, D-24105 Kiel, Germany
[2] Univ Kiel, Sch Med, Dept Radiol, D-24105 Kiel, Germany
关键词
IMPLANTATION; PROSTHESIS; CONDUIT;
D O I
10.1016/j.athoracsur.2006.01.096
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. In a recent study our group established an acute animal model of percutaneous pulmonary valve replacement using self-expanding nitinol stents. The present study was performed to evaluate these valved stents over a 3-month period. Description. Bovine jugular xenografts were sutured into nitinol stents. Transfemoral implantation in the pulmonary position using a modified commercially available application device (with a 22-French outer diameter) was evaluated in 9 sheep. Evaluation. Two sheep died shortly after successful valved stent implantation due to internal venous hemorrhage. Another 1 sheep died 2.5 months after the procedure due to vegetations on the neovalve leading to subtotal stenosis. All other animals survived the 3-month study time (n = 6). An orthotopic pulmonary valved stent position was achieved in 4 animals and a supravalvular position in 1. During the deployment procedure, rhythm disturbances occurred in all animals, and mean arterial blood pressure dropped from 83.9 +/- 26.0 mm Hg to 68.3 +/- 22.3 mm Hg (p = 0.006) (n = 5). The peak-to-peak transvalvular gradient was 5.1 +/- 4.0 mm Hg initially (n = 5), and 3.6 +/- 1.6 mm Hg at follow-up (n = 5). Three-month angiographic and echocardiographic follow-up confirmed competent neovalves without paravalvular leakages. Conclusions. After 3 months of implantation, percutaneously implanted memory nitinol valved stents demonstrated good function in the sheep.
引用
收藏
页码:708 / 714
页数:8
相关论文
共 12 条
[1]   Advances in experimental percutaneous pulmonary valve replacemen [J].
Attmann, T ;
Jahnke, T ;
Quaden, R ;
Boening, A ;
Muller-Hulsbeck, S ;
Cremer, J ;
Lutter, G .
ANNALS OF THORACIC SURGERY, 2005, 80 (03) :969-975
[2]   Percutaneous pulmonary valve replacement: 3-month evaluation of self-expanding valved stents [J].
Attmann, Tim ;
Quaden, Rene ;
Jahnke, Thomas ;
Muller-Hulsbeck, Stefan ;
Boening, Andreas ;
Cremer, Jochen ;
Lutter, Georg .
ANNALS OF THORACIC SURGERY, 2006, 82 (02) :708-714
[3]   Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction [J].
Bonhoeffer, P ;
Boudjemline, Y ;
Saliba, Z ;
Merckx, J ;
Aggoun, Y ;
Bonnet, D ;
Acar, P ;
Le Bidois, J ;
Sidi, D ;
Kachaner, J .
LANCET, 2000, 356 (9239) :1403-1405
[4]   Off-pump replacement of the pulmonary valve in large right ventricular outflow tracts: A hybrid approach [J].
Boudjemline, Y ;
Schievano, S ;
Bonnet, C ;
Coats, L ;
Agnoletti, G ;
Khambadkone, S ;
Bonnet, D ;
Deanfield, J ;
Sidi, D ;
Bonhoeffer, P .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (04) :831-837
[5]   The potential impact of percutaneous pulmonary valve stent implantation on right ventricular outflow tract re-intervention [J].
Coats, L ;
Tsang, V ;
Khambadkone, S ;
van Doorn, C ;
Cullen, S ;
Deanfield, J ;
de Leval, MR ;
Bonhoeffer, P .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (04) :536-542
[6]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[7]   One hundred pulmonary valve replacements in children after relief of right ventricular outflow tract obstruction [J].
Kanter, KR ;
Budde, JM ;
Parks, WJ ;
Tam, VKH ;
Sharma, S ;
Williams, WH ;
Fyfe, DA .
ANNALS OF THORACIC SURGERY, 2002, 73 (06) :1801-1806
[8]   Percutaneous valve replacement: Current state and future prospects [J].
Lutter, G ;
Ardehali, R ;
Cremer, J ;
Bonhoeffer, P .
ANNALS OF THORACIC SURGERY, 2004, 78 (06) :2199-2206
[9]   Transcatheter placement of a low-profile biodegradable pulmonary valve made of small intestinal submucosa: A long-term study in a swine model [J].
Ruiz, CE ;
Iemura, M ;
Medie, S ;
Varga, P ;
Van Alstine, WG ;
Mack, S ;
Deligio, A ;
Fearnot, N ;
Beier, UH ;
Pavcnik, D ;
Hijazi, ZM ;
Kiupel, M .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (02) :477-484
[10]   Percutaneous transcatheter aortic disc valve prosthesis implantation:: A feasibility study [J].
Sochman, J ;
Peregrin, JH ;
Pavcnik, D ;
Timmermans, H ;
Rösch, J .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (05) :384-388