Surface energy of experimental and commercial nanofiltration membranes: Effects of wetting and natural organic matter fouling

被引:100
作者
Roudman, AR [1 ]
DiGiano, FA [1 ]
机构
[1] Univ N Carolina, Dept Environm Sci & Engn, Chapel Hill, NC 27599 USA
关键词
nanofiltration; contact angle; membrane; geometric mean equation; surface property; natural organic matter; poly(1,1-dihydroperfluorooctyl methacrylate) and poly(2-dimethylaminoethyl methacrylate) diblock copolymer;
D O I
10.1016/S0376-7388(00)00409-9
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Contact angle measurements (captive bubble technique) were used to determine the surface energy of three experimental thin-film composite nanofiltration membranes and a commercial nanofiltration membrane (Hydranautics NTR 7450). The two experimental membranes of practical interest were thin film composites (diblock copolymer on a polysulfone support layer). The two blocks were poly(2-dimethylaminoethyl methacrylate) (PDMAEMA) and poly(1,1-dihydroperfluorooctyl methacrylate) (PFOMA). The concept was to devise a membrane material that takes advantage of the low adhesion of PFOMA to prevent fouling and the hydrophilic nature of PDMAEMA to produce high water permeation rates. Hydranautics NTR 7450 is a sulfonated polysulfone membrane that purportedly lessens fouling because the surface is more hydrophilic. The change in surface energy upon wetting, permeation of water containing natural organic matter (NOM) and chemical cleaning was of interest. Wetting caused reorganization of the experimental block copolymer surface to move more of PDMAEMA block to the membrane-water interface. After permeation of ultrapure water, however, the surface became more hydrophilic. After permeation of NOM containing water, the surface of both experimental and commercial membranes reached about the same surface energy, indicative of adsorption of NOM. The contact angle measurements were used to calculate a negative change in surface free energy for all but the PFOMA membrane; hence, with this exception, the deposition of NOM into a layer adjacent to the membrane surface was spontaneous. Scanning electron micrographs and atomic force micrographs showed that rigorous chemical cleaning failed to remove the NOM. Although the new polymeric materials were not more resistant to NOM fouling than commercial membranes, the surface energy calculations may help in the search for more successful polymers. Systematic study of charge, molecular size and specific functional groups of NOM on membrane fouling warrants further research to understand why similar fouling occurred on very different polymeric materials. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:61 / 73
页数:13
相关论文
共 21 条
[11]   TECHNIQUE FOR CHARACTERIZATION OF HYDROPHILIC SOLID SURFACES [J].
HAMILTON, WC .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1972, 40 (02) :219-&
[12]   Chemical and physical aspects of natural organic matter (NOM) fouling of nanofiltration membranes [J].
Hong, SK ;
Elimelech, M .
JOURNAL OF MEMBRANE SCIENCE, 1997, 132 (02) :159-181
[14]   A REINTERPRETATION OF ORGANIC LIQUID-POLYTETRAFLUOROETHYLENE SURFACE INTERACTIONS [J].
KAELBLE, DH ;
UY, KC .
JOURNAL OF ADHESION, 1970, 2 :50-&
[15]  
Nilson JA, 1996, J AM WATER WORKS ASS, V88, P53
[16]  
OWEN DM, 1995, J AM WATER WORKS ASS, V87, P46
[17]   FLUOROPOLYMERS OF VERY LOW SURFACE ENERGIES [J].
RAMHARACK, R ;
NGUYEN, TH .
JOURNAL OF POLYMER SCIENCE PART C-POLYMER LETTERS, 1987, 25 (03) :93-98
[18]  
White MC, 1997, J AM WATER WORKS ASS, V89, P64
[19]  
Wu S., 2017, POLYM INTERFACE ADHE
[20]   MEMBRANE CHARACTERIZATION BY THE CONTACT-ANGLE TECHNIQUE .2. CHARACTERIZATION OF UF-MEMBRANES AND COMPARISON BETWEEN THE CAPTIVE BUBBLE AND SESSILE DROP AS METHODS TO OBTAIN WATER CONTACT ANGLES [J].
ZHANG, W ;
WAHLGREN, M ;
SIVIK, B .
DESALINATION, 1989, 72 (03) :263-273